Sony VPL-VW1100ES: Maintenance

Maintenance: Sony VPL-VW1100ES

background image

21

 US

The lamp used for the light source has a 

certain lifespan. When the lamp dims, the 

color balance of the picture becomes 

strange, or “Please replace the Lamp.” 

appears on the screen, the lamp may be 

exhausted. Replace the lamp with a new one 

(not supplied) without delay.

Tools you need to get started:

Projector Lamp LMP-H330 (Optional)

Standard Phillips screwdriver

Cloth (for scratch protection)

• The lamp remains hot after the unit is turned 

off with the 

?

/

1

 (ON/STANDBY) button. If 

you touch the lamp, you may burn your 

fingers. When you replace the lamp, wait for 

at least 1 hour for the lamp to cool.

• Do not touch the surface of the lens. If you 

touch it, wipe off the fingerprints with a soft 

cloth.

• Pay special attention to replacing the lamp 

when the unit is installed on the ceiling.

• When replacing the lamp of a unit which is 

on the ceiling, do not stand  directly under the 

lamp cover. When removing the lamp door 

(inner cover), avoid twisting it.

If the lamp explodes, fragments may cause 

injury.

• When removing the lamp unit, make sure it 

remains horizontal, then pull straight up. Do 

not tilt the lamp unit. If you pull out the lamp 

unit while tilted and if the lamp breaks, the 

pieces may scatter, causing injury.

1

Turn off the unit and unplug the AC 

power cord.

2

When setting the unit on a flat surface 

such as a desk etc., put a cloth to 

prevent the surface from being 

scratched. Place the unit on the cloth.

Be sure that the unit is placed on a stable 

surface.

3

While pressing the 

 part indicated 

in the lamp cover illustration, slide 

1

and then open 

2

 the lamp cover.

4

Loosen the lamp door (inner cover) 

screw with a Phillips screwdriver, and 

then open the lamp door.

Maintenance

Replacing the Lamp

Caution

Note

background image

US 

22

5

Loosen the 3 screws on the lamp with 

the Phillips screwdriver. Hold up the 

handle, then pull the lamp straight out.

Hold the lamp by the handle to remove and 

attach it.

6

Push in the new lamp by the handle 

securely until it reaches the end, and 

then tighten the 3 screws.

Be careful not to touch the optical block 

inside the unit.

7

Close the lamp door, (inner cover) and 

then tighten the screw.

8

Close the lamp cover.

9

Wipe dust off the ventilation holes 

(intake) with a soft cloth.

Note

Note

Handle

Ventilation holes (intake)

background image

23

 US

10

Turn on the unit, then select the 

desired setting item on the Setup 

menu.

The menu screen below will be 

appeared.

11

Select “Yes.”

Do not put your hands into the lamp 

replacement slot, and do not allow any liquid or 

other objects into the slot to avoid electrical 

shock or fire.

• Be sure to use an LMP-H330 Projector Lamp 

for replacement. If you use lamps other than 

the LMP-H330, the unit may malfunction.

• Be sure to turn off the unit and unplug the 

power cord before replacing the lamp, then 

check the ON/STANDBY indicator has 

already been turned off.

• The unit will not turn on unless the lamp is 

securely installed in place.

• The unit will not turn on unless the lamp 

cover are securely closed.

• To cancel a message displayed on the screen, 

press either the button on the remote control 

or the one on the control panel on the unit.

Note on replacing the lamp when 

broken, in the case of a ceiling 

installation

If the lamp breaks, broken lamp pieces may 

scatter and cause injury.

When the unit is on the ceiling, remove the 

lamp door (inner cover) by sliding it 

horizontally slowly after raising it with 30 

degree opened. Avoid twisting the lamp door 

(inner cover).

Disposal of the used lamp

For the customers in the USA

Lamp in this product contains mercury. 

Disposal of these materials may be 

regulated due to environmental 

considerations. For disposal or 

recycling information, please contact 

your local authorities or the 

Telecommunications Industry 

Association (www.eiae.org).

Caution

Notes

Note

The lamp contains mercury. The disposal 

rules for used fluorescent tubes depend on 

where you live. Follow the waste disposal 

policy in your area.

30°