Panasonic S73MK1E5A: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру Panasonic S73MK1E5A
Operating Instructions
Air Conditioner
Wall Mounted
(K1 type)
Model No.
ENGLISH
2 ~ 9
INDOOR UNIT
Before operating the unit, read these operating instructions thoroughly and
ENGLISH
keep them for future reference.
Wall Mounted
(K1 type)
S-45MK1E5A
S-73MK1E5A
FRANÇAIS
10 ~ 17
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
FRANÇAIS
S-56MK1E5A
S-106MK1E5A
conservez-le pour toute référence ultérieure.
Connectable outdoor unit lineup
This booklet is the operating
ESPAÑOL
18 ~ 25
Antes de operar la unidad, lea atentamente estas instrucciones de
ESPAÑOL
instructions for indoor unit. Regarding
funcionamiento y guárdelas para futuras consultas.
the outdoor unit, see the operating
instructions supplied with the outdoor
DEUTSCH
26 ~ 33
unit.
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
DEUTSCH
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
OUTDOOR UNIT
ITALIANO
34 ~ 41
mini VRF (LE1 type)
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
ITALIANO
U-4LE1E5
U-4LE1E8
conservarle come riferimento futuro.
U-5LE1E5
U-5LE1E8
U-6LE1E5
U-6LE1E8
NEDERLANDS
42 ~ 49
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
NEDERLANDS
bewaar ze voor toekomstig gebruik.
2WAY VRF (ME1 type)
U-8ME1E81
U-16ME1E81
PORTUGUÊS
50 ~ 57
U-10ME1E81
U-18ME1E81
Antes de utilizar o aparelho, leia completamente este manual de instruções
PORTUGUÊS
U-12ME1E81
U-20ME1E81
e guarde-o para futuras referências.
U-14ME1H81
EΛΛΗΝΙΚΆ
58 ~ 65
3WAY VRF (MF2 type)
,
EΛΛΗΝΙΚΆ
.
U-8MF2E8
U-14MF2E8
U-10MF2E8
U-16MF2E8
БЪЛГАРСКИ
66 ~ 73
U-12MF2E8
,
БЪЛГАРСКИ
,
.
РУССКИЙ
74 ~ 81
РУССКИЙ
.
УКРАЇНСЬКА
82 ~ 89
,
УКРАЇНСЬКА
, .
B.INDONESIA
90 ~ 97
Sebelum mengoperasikan unit, baca petunjuk pengoperasian ini secara
B
.INDONESIA
menyeluruh dan simpan untuk referensi mendatang.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
CV623331150085464609285010
OI00284010EUall.indb1OI00284010EUall.indb1 2013/11/2914:35:292013/11/2914:35:29
Thank you for purchasing this Panasonic product.
This product is a commercial air conditioner indoor unit.
WARNING
Installation Instructions attached.
Confi rm to authorized dealer
or specialist on usage of
Contents
specifi ed refrigerant type. Using
Safety Precautions
........................................................... 2
of refrigerant other than the
Precautions for Use
......................................................... 4
specifi ed type may cause product
Names of Parts
................................................................. 5
damage, burst and injury etc.
• Operation Mechanism
................................................... 5
This air conditioner has no
Adjusting Airfl ow Direction
............................................. 6
• Adjusting airfl ow direction for multiple
ventilator for intaking fresh air
indoor units
.................................................................... 7
from outdoors. You must open
doors or windows frequently
Maintenance
..................................................................... 8
when you use gas or oil heating
• Before Requesting Services
......................................... 8
Troubleshooting
............................................................... 9
appliances in the same room,
which consume a lot of oxygen
Specifi cations
................................................................. 98
from the air.
• Indoor unit
.................................................................... 98
• Corresponding language table
................................... 98
Otherwise there is a risk of
suffocation in an extreme case.
Never use or store gasoline or
Product Information
other fl ammable vapor or liquid
near the air conditioner — it is
If you have problems or questions concerning your Air
very dangerous.
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of the
Do not use this appliance in a
cabinet.
potentially explosive atmosphere.
Model No.
Never touch the unit with wet hands.
Serial No.
Do not insert your fi ngers or
other objects into the air
Date of purchase
conditioner indoor or
outdoor unit, rotating parts may
Dealer’s address
cause injury.
Phone number
Refrigerant gas leakage may
cause fi re.
For safety, be sure to turn the
Safety Precautions
air conditioner off and also to
disconnect the power before
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel or
cleaning or servicing.
the appliance:
Pull off the power plug from
This symbol refers to a hazard or
a receptacle, or switch off
WARNING
unsafe practice which can result in
the breaker, or switch off
severe personal injury or death.
the power disconnecting mean to
This symbol refers to a hazard or
isolate the air conditioner from the
unsafe practice which can result
CAUTION
in personal injury or product or
main power supply in case of
property damage.
emergency.
Do not clean inside the indoor and
Matters to be
Prohibited matters
outdoor units by users. Engage
observed
authorized dealer or specialist for
cleaning.
• Read these Operating Instructions carefully before using this
air conditioner. If you still have any diffi culties or problems,
In case of malfunction of this
consult your dealer for help.
appliance, do not repair by
• This air conditioner is designed to give you comfortable
yourself. Contact to the sales
room conditions. Use this only for its intended purpose as
described in these Operating Instructions.
dealer or service dealer for a
repair.
2
OI00284010EUall.indb2OI00284010EUall.indb2 2013/11/2914:35:292013/11/2914:35:29
CAUTION
This appliance is intended to be used
Provide a power outlet to be
by expert or trained users in shops,in
used exclusively for each unit,
light industry and on farms, or for
and a power supply disconnect,
commercial use by lay persons.
circuit breaker and earth leakage
breaker for overcurrent protection
This appliance can be used by
should be provided in the
children aged from 8 years and
exclusive line.
above and persons with reduced
physical, sensory or mental
Provide a power outlet
capabilities or lack of experience and
exclusively for each unit, and full
knowledge if they have been given
disconnection means having a
supervision or instruction concerning
contact separation in all poles
use of the appliance in a safe
must be incorporated in the fi xed
way and understand the hazards
wiring in accordance with the
involved.
wiring rules.
ENGLISH
Keep the fi re alarm and the air outlet
To prevent possible hazards
at least 1.5m away from the unit.
from insulation failure, the
unit must be grounded.
Do not cool or heat the room too
much if babies or invalids are
Do not use modifi ed
present.
cord, joint cord,
extension cord or
Do not turn the air conditioner on
unspecifi ed cord to prevent
and off from the power mains switch.
overheating and fi re.
Use the ON/OFF operation button.
Do not stick anything into the air
Stop using the product when any
outlet of the outdoor unit. This
abnormality/failure occurs and
is dangerous because the fan
disconnect the power plug or turn
is rotating at high speed.
off the power switch and breaker.
Do not touch the air inlet or the
(Risk of smoke/fi re/electric shock)
sharp aluminum fi ns of the
Examples of abnormality/failure:
outdoor unit. You may get
• The ELCB trips frequently.
injured.
• The product sometimes does not
Do not stick any object
start when turned on.
into the FAN CASE. You
• The power is sometimes disconnected
may be injured and the
when the cord is moved.
unit may be damaged.
• Burnt odor or abnormal noise is
detected during operation.
• The body is deformed or
NOTICE
abnormally hot.
• The compressor may occasionally stop during thunderstorms.
• Water leaks from the indoor unit.
This is not a mechanical failure. The unit automatically
• Power cord or plug becomes
recovers after a few minutes.
• The English text is the original instructions. Other languages
abnormally hot.
are translation of the original instructions.
• Fan speed cannot be controlled.
• The unit stops running
Important Information Regarding
immediately even if it is switched
The Refrigerant Used
on for operation.
This product contains fl uorinated greenhouse gases covered
• The fan does not stop even if the
by the Kyoto Protocol. Do not vent gases into the atmosphere.
operation is stopped.
Refrigerant type: R410A
(1)
Contact immediately your local
GWP
value: 1975
(1)
dealer for maintenance/repair.
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact
Do not sit or step on the unit.
your local dealer for more information.
You may fall down
accidentally.
3
OI00284010EUall.indb3OI00284010EUall.indb3 2013/11/2914:35:302013/11/2914:35:30
Precautions for Use
Installation
Operation Condition
This air conditioner must be installed properly by qualifi ed
Use this air conditioner under the following temperature range.
installation technicians in accordance with the Installation
Instructions provided with the unit.
Indoor
Outdoor
Outdoor Unit
Before installation, check that the voltage of the electric sup-
temperature range
temperature range
ply in your home or offi ce is the same as the voltage shown
mini (LE1 type)
on the nameplate.
Cooling 14°C
25°C (*WBT) -10°C 46°C (*DBT)
Heating 16°C
30°C (*DBT) -20°C 18°C (*WBT)
WARNING
2WAY (ME1 type)
Cooling 14°C
25°C (*WBT) -10°C 46°C (*DBT)
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
Heating 16°C
30°C (*DBT) -25°C 15°C (*WBT)
Also locations of extremely high temperature such as a
3WAY (MF2 type)
greenhouse.
Cooling 14°C
25°C (*WBT) -10°C 46°C (*DBT)
Locations where excessively high heat-generating ob-
jects are placed.
Heating 15°C 30°C (*DBT) -20°C 18°C (*WBT)
Cooling &
-10°C
24°C (*DBT)
Heating
Attention:
*DBT: Dry bulb temperature
Avoid installing the outdoor unit where salty sea water can
*WBT: Wet bulb temperature
splash directly onto it or in sulphurous air near a spa.
(To protect the air conditioner from heavy corrosion)
Information for Users on Collection and Disposal of
Old Equipment and Used Batteries
Wiring
T
hese symbols on the products, packaging, and/
All wiring must conform to the local electrical codes.
or accompanying documents mean that used
(Consult your dealer or a qualifi ed electrician for details.)
electrical and electronic products and batteries
Each unit must be properly grounded with a ground (or
should not be mixed with general household waste.
earth) wire or through the supply wiring.
For proper treatment, recovery and recycling of
Wiring must be done by a qualifi ed electrician.
old products and used batteries, please take them
to applicable collection points, in accordance
with your national legislation and the Directives
Operation Preparation
2002/96/EC and 2006/66/EC.
By disposing of these products and batteries
Turn the power mains on 5 hours before
ON
correctly, you will help to save valuable resources
the start of operation.
and prevent any potential negative effects on
(For warm-up)
human health and the environment which could
Leave the power mains ON for continuous use.
otherwise arise from inappropriate waste handling.
For more information about collection and recycling
of old products and batteries, please contact your
local municipality, your waste disposal service or
NOTE
the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal
Pull off the power plug from a receptacle, or switch off the
of this waste, in accordance with national
breaker, or switch off the power disconnecting mean to isolate
legislation.
the air conditioner from the main power supply when not in use
For business users in the European Union
for a long time.
If you wish to discard electrical and electronic
equipment, please contact your dealer or supplier
for further information.
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European
Union. If you wish to discard these items, please
contact your local authorities or dealer and ask for
the correct method of disposal.
Note for the battery symbol (bottom two
symbol examples):
This symbol might be used in combination with
a chemical symbol. In this case it complies with
the requirement set by the Directive for the
chemical involved.
Pb
4
OI00284010EUall.indb4OI00284010EUall.indb4 2013/11/2914:35:312013/11/2914:35:31
Оглавление
- Contents
- Precautions for Use
- Names of Parts
- Adjusting Airfl ow Direction
- Maintenance
- Troubleshooting
- Table des matières
- Précautions d’utilisation
- Nom des pièces
- Réglage de la direction du fl ux d’air
- Entretien
- Dépannage
- Índice
- Precauciones de uso
- Nombres de las partes
- Mantenimiento
- Localización y resolución de problemas
- Sicherheitshinweise
- Vorsichtsmaßnahmen für den Gebrauch
- Bezeichnungen der Teile
- Einstellen der Ausblasrichtung
- Wartung
- Fehlerdiagnose
- Indice
- Precauzioni per l’uso
- Nome delle parti
- Manutenzione
- Risoluzione dei problemi
- Veiligheidsmaatregelen
- Voorzorgen in het gebruik
- Namen van de onderdelen
- Onderhoud
- Oplossen van problemen
- Índice
- Precauções de utilização
- Nomenclatura das peças
- Ajuste da direcção do fl uxo de ar
- Manutenção
- Localização e solução de problemas
- Περιεχόμενα
- Προφυλάξεις για χρήση
- Ονόματα μερών
- Ρύθμιση της κατεύθυνσης ροής αέρα
- Συντήρηση
- Αντιμετώπιση προβλημάτων
- Мерки за безопасност
- Предпазни мерки при употреба
- Наименования на компонентите
- Техническо обслужване
- Отстраняване на проблеми
- Меры предосторожности
- Меры предосторожности во время эксплуатации
- Названия частей
- Регулировка направления воздушного потока
- Техническое обслуживание
- Поиск и устранение неисправностей
- Заходи безпеки
- Заходи безпеки під час використання
- Назви деталей
- Регулювання напрямку потоку повітря
- Догляд
- Пошук та усунення несправностей
- Isi
- Petunjuk Penggunaan
- Nama Komponen
- Menyesuaikan Arah Aliran Udara
- Perawatan
- Pemecahan Masalah
- Specifi cations