Panasonic S140PT2E5: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру Panasonic S140PT2E5
Operating Instructions
Air Conditioner
Low Silhouette Ducted
Ceiling
(T2 type)
4-Way Cassette
(U1 type)
Model No.
(F1 type)
INDOOR UNIT
4-Way Cassette
(U1 type)
S-36PU1E5
S-71PU1E5
S-45PU1E5
S-100PU1E5
ENGLISH
2 ~ 9
S-50PU1E5
S-125PU1E5
Before operating the unit, read these operating instructions thoroughly and
ENGLISH
S-60PU1E5
S-140PU1E5
keep them for future reference.
Ceiling
(T2 type)
FRANÇAIS
10 ~ 17
S-36PT2E5
S-71PT2E5
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
FRANÇAIS
S-45PT2E5
S-100PT2E5
conservez-le pour toute référence ultérieure.
S-50PT2E5
S-125PT2E5
S-60PT2E5
S-140PT2E5
ESPAÑOL
18 ~ 25
Antes de operar la unidad, lea atentamente estas instrucciones de
ESPAÑOL
Low Silhouette Ducted
(F1 type)
funcionamiento y guárdelas para futuras consultas.
S-36PF1E5
S-71PF1E5
S-45PF1E5
S-100PF1E5
DEUTSCH
26 ~ 33
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
S-50PF1E5
S-125PF1E5
DEUTSCH
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
S-60PF1E5
S-140PF1E5
künftige Verwendung auf.
OUTDOOR UNIT
ITALIANO
34 ~ 41
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
ITALIANO
Single Split
(Single-phase)
conservarle come riferimento futuro.
PE1 Type
—
U-71PE1E5
NEDERLANDS
42 ~ 49
—
U-100PE1E5
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
NEDERLANDS
U-50PE1E5
U-125PE1E5
bewaar ze voor toekomstig gebruik.
U-60PE1E5
U-140PE1E5
PORTUGUÊS
50 ~ 57
Single Split
(3-phase)
Antes de utilizar o aparelho, leia completamente este manual de instruções
PORTUGUÊS
PE1 Type
e guarde-o para futuras referências.
—
U-71PE1E8
—
U-100PE1E8
EΛΛΗΝΙΚΆ
58 ~ 65
—
U-125PE1E8
,
EΛΛΗΝΙΚΆ
.
—
U-140PE1E8
Single Split
(Single-phase)
БЪЛГАРСКИ
66 ~ 73
,
PEY1 Type
БЪЛГАРСКИ
,
—
U-71PEY1E5
.
—
U-100PEY1E5
РУССКИЙ
74 ~ 81
—
U-125PEY1E5
РУССКИЙ
U-60PEY1E5
—
.
Single Split
(3-phase)
PEY1 Type
УКРАЇНСЬКА
82 ~ 90
,
УКРАЇНСЬКА
—
—
, .
—
U-100PEY1E8
—
U-125PEY1E8
—
U-140PEY1E8
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
F569021
F569021.indb1F569021.indb1 2013/06/079:37:302013/06/079:37:30
Thank you for purchasing this Panasonic
product.
Safety Precautions
This product is a commercial
air conditioner indoor unit.
Installation Instructions attached.
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel or
the appliance:
Contents
This symbol refers to a hazard or
WARNING
unsafe practice which can result in
severe personal injury or death.
Safety Precautions ......................................... 2
This symbol refers to a hazard or
unsafe practice which can result
Precautions for Use ........................................ 4
CAUTION
in personal injury or product or
property damage.
Names of Parts ................................................ 5
• Operation Mechanism .................................. 5
Matters to be
Prohibited matters
observed
Adjusting Airfl ow Direction ............................ 6
WARNING
• Adjusting airfl ow direction for multiple
indoor units ................................................... 7
Confi rm to authorized dealer or specialist on
usage of specifi ed refrigerant type. Using of
refrigerant other than the specifi ed type may
Maintenance .................................................... 8
cause product damage, burst and injury etc.
• Before Requesting Services ........................ 8
This air conditioner has no ventilator for intaking
Troubleshooting .............................................. 9
fresh air from outdoors. You must open doors
or windows frequently when you use gas or oil
heating appliances in the same room, which
consume a lot of oxygen from the air.
Specifi cations ............................................... 92
Otherwise there is a risk of suffocation in an
extreme case.
• Indoor unit ................................................... 92
Never use or store gasoline or other fl ammable
• Outdoor unit ................................................ 94
vapor or liquid near the air conditioner — it is
• Corresponding language table .................. 95
very dangerous.
Do not use this appliance in a potentially
explosive atmosphere.
Never touch the unit with wet hands.
Product Information
Do not insert your fi ngers or other
objects into the air conditioner indoor or
If you have problems or questions concerning your Air
outdoor unit, rotating parts may cause
Conditioner, you will need the following information. Model
injury.
and serial numbers are on the nameplate on the bottom of the
cabinet.
Refrigerant gas leakage may cause fi re.
Model No.
For safety, be sure to turn the air conditioner off
and also to disconnect the power before cleaning
or servicing.
Serial No.
Pull off the power plug from a receptacle,
or switch off the breaker, or switch off
the power disconnecting mean to isolate
Date of purchase
the air conditioner from the main power
supply in case of emergency.
Do not clean inside the indoor and outdoor units
Dealer’s address
by users. Engage authorized dealer or specialist
for cleaning.
In case of malfunction of this appliance, do not
Phone number
repair by yourself. Contact to the sales dealer or
service dealer for a repair.
2
F569021.indb2F569021.indb2 2013/06/079:37:392013/06/079:37:39
• Read these Operating Instructions carefully before using this
air conditioner. If you still have any diffi culties or problems,
CAUTION
consult your dealer for help.
• This air conditioner is designed to give you comfortable
This appliance is intended to be used by expert or
room conditions. Use this only for its intended purpose as
trained users in shops,in light industry and on farms,
described in these Operating Instructions.
or for commercial use by lay persons.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that do not play with the
appliance.
Keep the fi re alarm and the air outlet at least 1.5m
away from the unit.
Do not cool or heat the room too much if babies or
ENGLISH
invalids are present.
Provide a power outlet to be used exclusively
for each unit, and a power supply disconnect,
Do not turn the air conditioner on and off from the
circuit breaker and earth leakage breaker for
power mains switch. Use the ON/OFF operation
overcurrent protection should be provided in the
button.
exclusive line.
Do not stick anything into the air outlet of the
Provide a power outlet exclusively for each unit,
outdoor unit. This is dangerous because the
and full disconnection means having a contact
fan is rotating at high speed.
separation in all poles must be incorporated in
the fi xed wiring in accordance with the wiring
Do not touch the air inlet or the sharp
rules.
aluminum fi ns of the outdoor unit. You may
get injured.
To prevent possible hazards from
insulation failure, the unit must be
Do not sit or step on the unit. You may fall
grounded.
down accidentally.
Do not use modifi ed cord,
joint cord, extension cord or
Do not stick any object into the FAN
unspecifi ed cord to prevent
CASE. You may be injured and the
overheating and fi re.
unit may be damaged.
NOTICE
Stop using the product when any abnormality/
failure occurs and disconnect the power plug or
• The compressor may occasionally stop during thunderstorms.
turn off the power switch and breaker.
This is not a mechanical failure. The unit automatically
(Risk of smoke/fi re/electric shock)
recovers after a few minutes.
Examples of abnormality/failure
• The English text is the original instructions. Other languages
• The ELCB trips frequently.
are translation of the original instructions.
• The product sometimes does not start when
turned on.
Important Information Regarding
• The power is sometimes disconnected when
the cord is moved.
The Refrigerant Used
• Burnt odor or abnormal noise is detected during
This product contains fl uorinated greenhouse gases covered
operation.
by the Kyoto Protocol. Do not vent gases into the atmosphere.
• The body is deformed or abnormally hot.
Refrigerant type: R410A
• Water leaks from the indoor unit.
(1)
• Power cord or plug becomes abnormally hot.
GWP
value: 1975
• Fan speed cannot be controlled.
(1)
GWP = global warming potential
• The unit stops running immediately even if it is
Periodical inspections for refrigerant leaks may be required
switched on for operation.
depending on European or local legislation. Please contact
• The fan does not stop even if the operation is
your local dealer for more information.
stopped.
Contact immediately your local dealer for
maintenance/repair.
3
F569021.indb3F569021.indb3 2013/06/079:37:432013/06/079:37:43
Precautions for Use
Installation
Operation Condition
This air conditioner must be installed properly by qualifi ed
Use this air conditioner under the following temperature range.
installation technicians in accordance with the Installation
Indoor temperature range:
Instructions provided with the unit.
Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT)
Before installation, check that the voltage of the electric sup-
Heating mode 16°C ~ 30°C (*DBT)
ply in your home or offi ce is the same as the voltage shown
on the nameplate.
Outdoor temperature range:
Cooling mode -15°C ~ 46°C (*DBT)
*1 -10°C ~ 43°C (*DBT)
WARNING
Heating mode -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)
*1 -15°C ~ 18°C (*WBT) / -15°C ~ 24°C (*DBT)
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
*DBT: Dry bulb temperature
Also locations of extremely high temperature such as a
*WBT: Wet bulb temperature
greenhouse.
*1 When connecting U-60PEY1E5, U-71PEY1E5,
Locations where excessively high heat-generating ob-
U-100PEY1E5, U-100PEY1E8, U-125PEY1E5,
jects are placed.
U-125PEY1E8, U-140PEY1E8
Attention:
Information for Users on Collection and Disposal of
Old Equipment and Used Batteries
Avoid installing the outdoor unit where salty sea water can
splash directly onto it or in sulphurous air near a spa.
T
hese symbols on the products, packaging,
(To protect the air conditioner from heavy corrosion)
and/or accompanying documents mean that
used electrical and electronic products and
batteries should not be mixed with general
Wiring
household waste.
For proper treatment, recovery and recycling
All wiring must conform to the local electrical codes.
of old products and used batteries, please
(Consult your dealer or a qualifi ed electrician for details.)
take them to applicable collection points, in
Each unit must be properly grounded with a ground (or
accordance with your national legislation and
earth) wire or through the supply wiring.
the Directives 2002/96/EC and 2006/66/EC.
Wiring must be done by a qualifi ed electrician.
By disposing of these products and batteries
correctly, you will help to save valuable
resources and prevent any potential negative
Operation Preparation
effects on human health and the environment
which could otherwise arise from inappropriate
Turn the power mains on 5 hours before
ON
waste handling.
the start of operation.
For more information about collection and
(For warm-up)
recycling of old products and batteries, please
Leave the power mains ON for continuous use.
contact your local municipality, your waste
disposal service or the point of sale where you
purchased the items.
Penalties may be applicable for incorrect
NOTE
disposal of this waste, in accordance with
national legislation.
Pull off the power plug from a receptacle, or switch off the
For business users in the European Union
breaker, or switch off the power disconnecting mean to isolate
If you wish to discard electrical and electronic
the air conditioner from the main power supply when not in use
equipment, please contact your dealer or
for a long time.
supplier for further information.
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European
Union. If you wish to discard these items,
please contact your local authorities or dealer
and ask for the correct method of disposal.
Note for the battery symbol (bottom two
symbol examples):
This symbol might be used in combination with
a chemical symbol. In this case it complies
with the requirement set by the Directive for
the chemical involved.
Pb
4
F569021.indb4F569021.indb4 2013/06/079:37:472013/06/079:37:47
Оглавление
- Safety Precautions
- Precautions for Use
- Names of Parts
- Adjusting Airfl ow Direction
- Maintenance
- Troubleshooting
- Table des matières
- Précautions d’utilisation
- Nom des pièces
- Réglage de la direction du fl ux d’air
- Entretien
- Dépannage
- Índice
- Precauciones de uso
- Nombres de las partes
- Mantenimiento
- Localización y resolución de problemas
- Sicherheitshinweise
- Vorsichtsmaßnahmen für den Gebrauch
- Bezeichnungen der Teile
- Einstellen der Ausblasrichtung
- Wartung
- Fehlerdiagnose
- Indice
- Precauzioni per l’uso
- Nome delle parti
- Manutenzione
- Risoluzione dei problemi
- Veiligheidsmaatregelen
- Voorzorgen in het gebruik
- Namen van de onderdelen
- Onderhoud
- Oplossen van problemen
- Índice
- Precauções de utilização
- Nomenclatura das peças
- Ajuste da direcção do fl uxo de ar
- Manutenção
- Localização e solução de problemas
- Περιεχόμενα
- Προφυλάξεις για χρήση
- Ονόματα μερών
- Ρύθμιση της κατεύθυνσης ροής αέρα
- Συντήρηση
- Αντιμετώπιση προβλημάτων
- Мерки за безопасност
- Предпазни мерки при употреба
- Наименования на компонентите
- Техническо обслужване
- Отстраняване на проблеми
- Меры предосторожности
- Меры предосторожности во время эксплуатации
- Названия частей
- Регулировка направления воздушного потока
- Техническое обслуживание
- Поиск и устранение неисправностей
- Заходи безпеки
- Заходи безпеки під час використання
- Назви деталей
- Регулювання напрямку потоку повітря
- Догляд
- Пошук та усунення несправностей
- MEMO
- Specifi cations
- MEMO