Panasonic CZRE2C2: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру Panasonic CZRE2C2
Save These Instructions!
Conserver ce mode d’emploi!
Diese Anleitung aufbewhren!
Conservare queste istruzioni!
Guarde estas instruções!
Εκτός αττό αυτές τις οδηγίες!
Guarde estas instruccónes!
Сохраните эту инструкцию!
Збережіть ці інструкції!
CZ-RE2C2
Simplified Remote Controller For Split System
INSTRUCTION MANUAL
EN
Air Conditioner
Télécommande simplifiée pour climatiseur à
MANUEL D’INSTRUCTIONS
FR
deux blocs
Vereinfachte Fernbedienung für Split-System-
BEDIENUNGSANLEITUNG
DE
Klimagerät
Telecomando semplificato per condizionatore
MANUAL DI ISTRUZIONI
IT
d’aria a sistema split
Controlador remoto simplificado para o
MANUAL DE INSTRUÇÕES
PT
aparelho de ar condicionado de sistema split
Απλοποιημένο Τηλεχειριστήριο Για Κλιματιστικό
ΟΔΗΓΙΕΣ ΧΡHΣHΣ
GR
Αέρος Διαιρετού Συστήματος
Mando a distancia simplificado para el sistema
MANUAL DE INSTRUCCIONES
ES
de aire acondicionado de dos unidades
Упрощенный пульт дистанционного управления
ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ
RU
для сплит-системы кондиционирования
Спрощений пульт дистанційного керування
ПОСІБНИК КОРИСТУВАЧА
UA
для кондиціонерів роздільного типу
85464609074021
Contents
1. Important Safety Instructions.....................EN-1 3. Outing Function ...................................EN-4
EN
2. Names and Operations .............................EN-2
Table des matières
1. Mesures de sécurité importantes ..............FR-1 3. Fonction de maintien ........................... FR-4
FR
2. Noms et fonctionnement ...........................FR-2
Inhalt
1. Wichtige Sicherheitshinweise....................DE-1 3. Outing-Funktion ................................... DE-4
DE
2. Bezeichnungen und Funktionen................DE-2
Indice
1. Importanti istruzioni di sicurezza ...............IT-1 3. Funzione stanza vuota ........................IT-4
IT
2. Nomi e operazioni .....................................IT-2
Índice
1. Instruções de segurança importantes .......PT-1 3. Função de controlo..............................PT-4
PT
2. Nomes e operações..................................PT-2
Πίνακας περιεχομένων
1. Σημαντικές οδηγίες για την ασφάλεια ........GR-1 3. Λειτουργία εξόδου αέρα....................... GR-4
GR
2. Ονομασίες και λειτουργίες .........................GR-2
índice
1.
Instrucciones de seguridad importantes
....ES-1 3. Función de control de la temperatura... ES-4
ES
2. Nombres y funciones.................................ES-2
Содержание
1. Важные инструкции по безопасности ....RU-1 3. Функция выключения.........................RU-4
RU
2. Названия и операции ..............................RU-2
Зміст
1. Важливі заходи безпеки ..........................UA-1 3. Режим «Порожня кімната» ................ UA-4
UA
2.
Елементи управління, режими роботи та індикації
...UA-2
1. Important Safety Instructions
Before using the system, be sure to read these “Important Safety Instructions”.
After reading this manual, save it in a convenient place.
Warning
*Installation Precautions
*Precautions for Use
・Do not install by yourself
・Do not touch switches with wet hands
Installation should always be performed by
Electric shock and damage to the system can
your dealer or a professional service provider.
result.
Electric shock or fire may result if an
・Protect the remote controller from water
inexperienced person performs any installation
Damage to the system can result.
or wiring procedures incorrectly.
・Stop the system and turn the power off if you
・Use only specified air conditioners
sense unusual smells or other irregularities
Always use only air conditions specified by the
Continuing operation when the system is out
dealer.
of order can result in electric shock, fire,and
EN
damage to the system. Contact your dealer.
・Do not turn the air conditioner on and off from
*Moving and Repair Precautions
the power mains switch. Use the ON/OFF
operation button.
・Do not repair
・Do not stick anything into the air outlet of the
Never repair the system by yourself.
air conditioner. Doing so is dangerous because
・Contact your dealer before moving the system
the fan is rotating at high speed.
Contact your dealer or a professional service
・Do not let children play with the air conditioner.
provider about moving and reinstalling the
・Do not cool or heat the room too much if babies
system.
or invalids are present.
Electric shock or fire may result if an
・Do not wipe the remote controller with benzine,
inexperienced person performs any installation
thinner, or chemical cloth.
procedures incorrectly.
EN-1
2. Names and Operations
Operation Section
1. (Start/Stop) button
6. (Outing function) button
Pushing this button starts, and pushing again
( Outing Function)
stops the unit.
1
2
3
4
5
6
7
2. (Temperature setting) buttons
Changing the temperature setting.
3. (Mode Select) button
Pushing this button to select an operation
mode. (AUTO → HEAT → DRY →
COOL → FAN ).
4. (Fan speed) button
EN
Changing the fan speed.
( / / / )
15
14 12
1113
910
8
5. (Swing/Air direction) button *1
Use this button to set the auto swing or air
direction to a specific angle.
*1 Do not move the flap (vertical airflow
adjustment board) with your hand.
・The flap is automatically directed down
when the unit is stopped.
・The flap is directed up during the HEAT
3
standby. The flap starts swinging after the
4
HEAT standby is cancelled, although the
2
AUTO flap indication on the remote control
5
unit is displayed during the HEAT standby.
6
1
EN-2
Display Section
1.
(Fan mode select)
/ / /
10. (Centralized control) indication
indication
Appears when operated in centralized control.
The selected fan mode is displayed.
If the remote control operation is not permitted
to the remote unit, when the (Start/Stop)
2. (Flap position) indication
button, (Mode select) button,
Indicates the flap position.
(Fan speed) button, (Swing/Air direction)
button or (Temperature setting)
3. (Swing) indication
buttons are pressed, flashes and
Appears while the flap swings.
rejects the change.
4. (Outing) indication
( Outing Function)
11. (Disabled feature) indication
Appears when the outing function is set.
Displayed if the selected feature was disabled
during installation.
5. Operation Mode indication
Displays the selected operation mode.
12. (Heating standby mode) indication
EN
(AUTO /HEAT /DRY /COOL /
appears when the fan of the indoor unit is
FAN ).
stopped or in low fan speed.
6. Upper and lower limit indication of the
13. (Caution) indication
outing function
Appears when the protective device is
: Indicates the upper limit of the
activated or when an abnormality occurs.
temperature
: Indicates the lower limit of the
14. Alarm indication
temperature
This displays alarm messages when an error
occurs.
7. Temperature indication
Indicates the set temperature.
15. (Oil) indication
Appears when the engine oil needs to be
8. °F / °C (Temperature unit) indication
changed. (Appears when the gas heat pump
air conditioner is used.)
9. (Remote control sensor) indication
Appears when the remote control sensor is
used.
EN-3
3. Outing Function
Outing function is a function that prevents the room temperature from increasing too much (or
decreasing too much) when no one is in the room.
An air conditioner works automatically if this function is set effective.
General Performance of the Outing Function
Outing function upper limit
COOL / DRY
① The air conditioner starts operation when the room
temperature increases up to –1°C of the upper
limit.
② The air conditioner stops operation when the room
temperature decreases up to –2°C of the upper
limit.
Room temperature
HEAT
Room temperature
EN
EN
① The air conditioner starts operation when the room
temperature decreases up to +1°C of the lower
limit.
② The air conditioner stops operation when the room
temperature increases up to +2°C of the lower
limit.
Outing function Lower limit
[Precautions]
・The outing control only starts/stops the air conditioner. It does not change the operation mode/
temperature setting.
Therefore, the operation mode/temperature needs to be set beforehand so that the outing function
turns on the air conditioner with your desired operation mode/ temperature setting.
・If the room temperature rapidly changes, the room temperature may get over the upper or lower limit
when the outing function is activated.
・The outing function is invalid during FAN/AUTO operation mode.
・The air conditioner's stop order (stated in ② ⁄ above) is valid only when the outing function is
operated.
If operated using other remote control units (or a centralized control device such as a system control),
the outing function will not stop air conditioner operation.
EN-4
3. Outing Function (Continued)
• Setting the Outing Function
1.Press and hold for more than 4 seconds to display the upper limit
temperature setting screen.
, and the upper limit temperature start flashing.
(The default value of the upper limit temperature is 38 °C.)
2.Press / to select the upper limit temperature, and press to
fix the value. The lower limit temperature setting screen is displayed.
2
3.Press / to select the lower limit temperature, and press to
fix the value. The outing function setting is completed. (The default value of
the lower limit temperature is 10 °C.)
*The unit returns to the normal mode if is pressed or there is no operation made for
3 minutes during the setting. In this case, all the settings in progress will be lost.
• Canceling the outing function
3
EN
Press and hold for more than 4 seconds while the outing function is set.
• Outing function indication
Outing function
Status
indication
Off
The outing function is not set.
Flashing
The outing function is now being set, or under operation.
Lighting
Although the outing function is set, not under operation.
Note
If a blackout occurs during outing function operation and power is cut, the remote controller will lose
the information for outing function operation. It reverts from the blackout, and an air conditioner does not
drive in outing function when operation is started. At this time, an air conditioner does not stop at outing
function.
EN-5