ADJUSTING AIRFLOW DIRECTION

The functions differ depending on the indoor unit used. The airflow direction cannot be set

using the remote controller for any unit which is not listed below.

U1 type, Y1 type, T1 type and K1 type.

Never use your hands to move the flap (vertical airflow flap) that is controlled using the

remote controller.

When the air conditioner is turned off, the flap (vertical airflow flap) automatically moves to

the downward position.

The flap (vertical airflow flap) moves to the upward position when performing the standby

operation for heating. The swing operation is made after the standby operation for heating is

released, but swing is indicated on the remote controller even during the standby operation

for heating.

Setting the airflow

The airflow direction changes each time the FLAP button is pressed during operation.

direction

To activate the swing

Press the FLAP button to set the flap (vertical airflow flap) to the downward position, and then

operation

press the FLAP button again. This displays , and the airflow automatically swings up and

down.

Heating Cooling and drying Fan operation All operations

Set the flap (vertical airflow flap) to the downward

The flap (vertical airflow flap) can

position. If the flap is set to the upward position,

be set to one of three positions.

the warm air may not reach the floor.

Continuous

Initial setting

operation

Initial setting

Initial setting

To stop the swing

Press the FLAP button again during the flap swing operation to stop the flap at the desired

operation

position. Then, the airflow can be set from the top position by pressing the FLAP button again.

Indicator when swing operation is stopped

Fan and heating Cooling and drying

During cooling or drying operation, the flap will not stop at the downward position. Even if the

flap is stopped at the downward position during the swing operation, it will not stop until it

moves to the third position from the top.

8

01_85464609230020_EN.fm Page 9 Thursday, December 27, 2012 4:22 PM

ADJUSTING AIRFLOW DIRECTION (CONTINUED)

U1 type air conditioner is equipped with auto flaps.

You can set the airflow direction to a specific angle or to the sweep mode using the remote

controller.

Do not move the flap with your hands.

4-way (U1, Y1 type) The air outlet flap can be easily removed and washed with water.

Be sure to always stop operation before removing the flap.

After washing with water, allow it to dry, and then remount it with the arrow facing outward.

Ceiling mounted type (T1)

Vertical directions (automatic)

This air conditioner is equipped with an auto flap. You can set the airflow direction to a specific

angle or to the sweep mode using the remote controller. (Refer to the description of the remote

controller.)

Do not move the flap with your hands.

Horizontal directions (manual)

The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the

left or right.

Wall mounted type (K1)

Vertical directions (automatic)

Confirm that the remote controller has been turned on. Press the FLAP button to start the flap

Indoor unit

moving up and down. If you want to stop the flap movement and to direct the air in the desired

direction, press the FLAP button again. In the cool mode, do not direct the flap down and move

out of the cooling zone “A”, otherwise, condensation may drip on to the floor. Zone ‘‘A’’ is the

recommended flap position for cooling.

When operating continuously in the fixed airflow direction setting for about an hour, the airflow

direction is automatically controlled and the flap position is changed. The airflow direction may

be different from the display on the remote controller.

Do not move the flap with your hands.

Zone

‘‘A’’ for

Horizontal directions (manual)

cooling

Zone ‘‘B’’ for

The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the

heating

left or right.

Concealed duct type (F1, N1)

This air conditioner is not equipped with air outlet parts. These must be obtained locally. Please

refer to the manual of the locally adopted air outlet parts.