Panasonic S71PT2E5: инструкция

Раздел: Бытовая, кухонная техника, электроника и оборудование

Тип: Кондиционер

Инструкция к Кондиционеру Panasonic S71PT2E5

Operating Instructions

Air Conditioner

Low Silhouette Ducted

Ceiling

(T2 type)

4-Way Cassette

(U1 type)

Model No.

(F1 type)

INDOOR UNIT

4-Way Cassette

(U1 type)

S-36PU1E5

S-71PU1E5

S-45PU1E5

S-100PU1E5

ENGLISH

2 ~ 9

S-50PU1E5

S-125PU1E5

Before operating the unit, read these operating instructions thoroughly and

ENGLISH

S-60PU1E5

S-140PU1E5

keep them for future reference.

Ceiling

(T2 type)

FRANÇAIS

10 ~ 17

S-36PT2E5

S-71PT2E5

Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et

FRANÇAIS

S-45PT2E5

S-100PT2E5

conservez-le pour toute référence ultérieure.

S-50PT2E5

S-125PT2E5

S-60PT2E5

S-140PT2E5

ESPAÑOL

18 ~ 25

Antes de operar la unidad, lea atentamente estas instrucciones de

ESPAÑOL

Low Silhouette Ducted

(F1 type)

funcionamiento y guárdelas para futuras consultas.

S-36PF1E5

S-71PF1E5

S-45PF1E5

S-100PF1E5

DEUTSCH

26 ~ 33

Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese

S-50PF1E5

S-125PF1E5

DEUTSCH

Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die

S-60PF1E5

S-140PF1E5

künftige Verwendung auf.

OUTDOOR UNIT

ITALIANO

34 ~ 41

Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e

ITALIANO

Single Split

(Single-phase)

conservarle come riferimento futuro.

PE1 Type

U-71PE1E5

NEDERLANDS

42 ~ 49

U-100PE1E5

Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en

NEDERLANDS

U-50PE1E5

U-125PE1E5

bewaar ze voor toekomstig gebruik.

U-60PE1E5

U-140PE1E5

PORTUGUÊS

50 ~ 57

Single Split

(3-phase)

Antes de utilizar o aparelho, leia completamente este manual de instruções

PORTUGUÊS

PE1 Type

e guarde-o para futuras referências.

U-71PE1E8

U-100PE1E8

EΛΛΗΝΙΚΆ

58 ~ 65

U-125PE1E8

     ,      

EΛΛΗΝΙΚΆ

      .

U-140PE1E8

Single Split

(Single-phase)

БЪЛГАРСКИ

66 ~ 73

      ,  

PEY1 Type

БЪЛГАРСКИ

   ,       

U-71PEY1E5

.

U-100PEY1E5

РУССКИЙ

74 ~ 81

U-125PEY1E5

     

РУССКИЙ

U-60PEY1E5

      

 .

Single Split

(3-phase)

PEY1 Type

УКРАЇНСЬКА

82 ~ 90

      , 

УКРАЇНСЬКА

 ,     .

U-100PEY1E8

U-125PEY1E8

U-140PEY1E8

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

F569021

F569021.indb1F569021.indb1 2013/06/079:37:302013/06/079:37:30

Thank you for purchasing this Panasonic

product.

Safety Precautions

This product is a commercial

air conditioner indoor unit.

Installation Instructions attached.

The following symbols used in this manual, alert you to

potentially dangerous conditions to users, service personnel or

the appliance:

Contents

This symbol refers to a hazard or

WARNING

unsafe practice which can result in

severe personal injury or death.

Safety Precautions ......................................... 2

This symbol refers to a hazard or

unsafe practice which can result

Precautions for Use ........................................ 4

CAUTION

in personal injury or product or

property damage.

Names of Parts ................................................ 5

• Operation Mechanism .................................. 5

Matters to be

Prohibited matters

observed

Adjusting Air ow Direction ............................ 6

WARNING

• Adjusting air ow direction for multiple

indoor units ................................................... 7

Con rm to authorized dealer or specialist on

usage of speci ed refrigerant type. Using of

refrigerant other than the speci ed type may

Maintenance .................................................... 8

cause product damage, burst and injury etc.

Before Requesting Services ........................ 8

This air conditioner has no ventilator for intaking

Troubleshooting .............................................. 9

fresh air from outdoors. You must open doors

or windows frequently when you use gas or oil

heating appliances in the same room, which

consume a lot of oxygen from the air.

Speci cations ............................................... 92

Otherwise there is a risk of suffocation in an

extreme case.

• Indoor unit ................................................... 92

Never use or store gasoline or other ammable

• Outdoor unit ................................................ 94

vapor or liquid near the air conditioner — it is

Corresponding language table .................. 95

very dangerous.

Do not use this appliance in a potentially

explosive atmosphere.

Never touch the unit with wet hands.

Product Information

Do not insert your ngers or other

objects into the air conditioner indoor or

If you have problems or questions concerning your Air

outdoor unit, rotating parts may cause

Conditioner, you will need the following information. Model

injury.

and serial numbers are on the nameplate on the bottom of the

cabinet.

Refrigerant gas leakage may cause re.

Model No.

For safety, be sure to turn the air conditioner off

and also to disconnect the power before cleaning

or servicing.

Serial No.

Pull off the power plug from a receptacle,

or switch off the breaker, or switch off

the power disconnecting mean to isolate

Date of purchase

the air conditioner from the main power

supply in case of emergency.

Do not clean inside the indoor and outdoor units

Dealer’s address

by users. Engage authorized dealer or specialist

for cleaning.

In case of malfunction of this appliance, do not

Phone number

repair by yourself. Contact to the sales dealer or

service dealer for a repair.

2

F569021.indb2F569021.indb2 2013/06/079:37:392013/06/079:37:39

• Read these Operating Instructions carefully before using this

air conditioner. If you still have any dif culties or problems,

CAUTION

consult your dealer for help.

• This air conditioner is designed to give you comfortable

This appliance is intended to be used by expert or

room conditions. Use this only for its intended purpose as

trained users in shops,in light industry and on farms,

described in these Operating Instructions.

or for commercial use by lay persons.

This appliance is not intended for use by persons

(including children) with reduced physical, sensory

or mental capabilities, or lack of experience and

knowledge, unless they have been given supervision

or instruction concerning use of the appliance by a

person responsible for their safety. Children should

be supervised to ensure that do not play with the

appliance.

Keep the re alarm and the air outlet at least 1.5m

away from the unit.

Do not cool or heat the room too much if babies or

ENGLISH

invalids are present.

Provide a power outlet to be used exclusively

for each unit, and a power supply disconnect,

Do not turn the air conditioner on and off from the

circuit breaker and earth leakage breaker for

power mains switch. Use the ON/OFF operation

overcurrent protection should be provided in the

button.

exclusive line.

Do not stick anything into the air outlet of the

Provide a power outlet exclusively for each unit,

outdoor unit. This is dangerous because the

and full disconnection means having a contact

fan is rotating at high speed.

separation in all poles must be incorporated in

the xed wiring in accordance with the wiring

Do not touch the air inlet or the sharp

rules.

aluminum ns of the outdoor unit. You may

get injured.

To prevent possible hazards from

insulation failure, the unit must be

Do not sit or step on the unit. You may fall

grounded.

down accidentally.

Do not use modi ed cord,

joint cord, extension cord or

Do not stick any object into the FAN

unspeci ed cord to prevent

CASE. You may be injured and the

overheating and re.

unit may be damaged.

NOTICE

Stop using the product when any abnormality/

failure occurs and disconnect the power plug or

• The compressor may occasionally stop during thunderstorms.

turn off the power switch and breaker.

This is not a mechanical failure. The unit automatically

(Risk of smoke/ re/electric shock)

recovers after a few minutes.

Examples of abnormality/failure

• The English text is the original instructions. Other languages

• The ELCB trips frequently.

are translation of the original instructions.

• The product sometimes does not start when

turned on.

Important Information Regarding

• The power is sometimes disconnected when

the cord is moved.

The Refrigerant Used

• Burnt odor or abnormal noise is detected during

This product contains uorinated greenhouse gases covered

operation.

by the Kyoto Protocol. Do not vent gases into the atmosphere.

• The body is deformed or abnormally hot.

Refrigerant type: R410A

• Water leaks from the indoor unit.

(1)

• Power cord or plug becomes abnormally hot.

GWP

value: 1975

• Fan speed cannot be controlled.

(1)

GWP = global warming potential

• The unit stops running immediately even if it is

Periodical inspections for refrigerant leaks may be required

switched on for operation.

depending on European or local legislation. Please contact

• The fan does not stop even if the operation is

your local dealer for more information.

stopped.

Contact immediately your local dealer for

maintenance/repair.

3

F569021.indb3F569021.indb3 2013/06/079:37:432013/06/079:37:43

Precautions for Use

Installation

Operation Condition

This air conditioner must be installed properly by quali ed

Use this air conditioner under the following temperature range.

installation technicians in accordance with the Installation

Indoor temperature range:

Instructions provided with the unit.

Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT)

Before installation, check that the voltage of the electric sup-

Heating mode 16°C ~ 30°C (*DBT)

ply in your home or of ce is the same as the voltage shown

on the nameplate.

Outdoor temperature range:

Cooling mode -15°C ~ 46°C (*DBT)

*1 -10°C ~ 43°C (*DBT)

WARNING

Heating mode -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)

*1 -15°C ~ 18°C (*WBT) / -15°C ~ 24°C (*DBT)

Avoid the following locations for installation.

Locations where smoke or combustible gas exists.

*DBT: Dry bulb temperature

Also locations of extremely high temperature such as a

*WBT: Wet bulb temperature

greenhouse.

*1 When connecting U-60PEY1E5, U-71PEY1E5,

Locations where excessively high heat-generating ob-

U-100PEY1E5, U-100PEY1E8, U-125PEY1E5,

jects are placed.

U-125PEY1E8, U-140PEY1E8

Attention:

Information for Users on Collection and Disposal of

Old Equipment and Used Batteries

Avoid installing the outdoor unit where salty sea water can

splash directly onto it or in sulphurous air near a spa.

T

hese symbols on the products, packaging,

(To protect the air conditioner from heavy corrosion)

and/or accompanying documents mean that

used electrical and electronic products and

batteries should not be mixed with general

Wiring

household waste.

For proper treatment, recovery and recycling

All wiring must conform to the local electrical codes.

of old products and used batteries, please

(Consult your dealer or a quali ed electrician for details.)

take them to applicable collection points, in

Each unit must be properly grounded with a ground (or

accordance with your national legislation and

earth) wire or through the supply wiring.

the Directives 2002/96/EC and 2006/66/EC.

Wiring must be done by a quali ed electrician.

By disposing of these products and batteries

correctly, you will help to save valuable

resources and prevent any potential negative

Operation Preparation

effects on human health and the environment

which could otherwise arise from inappropriate

Turn the power mains on 5 hours before

ON

waste handling.

the start of operation.

For more information about collection and

(For warm-up)

recycling of old products and batteries, please

Leave the power mains ON for continuous use.

contact your local municipality, your waste

disposal service or the point of sale where you

purchased the items.

Penalties may be applicable for incorrect

NOTE

disposal of this waste, in accordance with

national legislation.

Pull off the power plug from a receptacle, or switch off the

For business users in the European Union

breaker, or switch off the power disconnecting mean to isolate

If you wish to discard electrical and electronic

the air conditioner from the main power supply when not in use

equipment, please contact your dealer or

for a long time.

supplier for further information.

[Information on Disposal in other Countries

outside the European Union]

These symbols are only valid in the European

Union. If you wish to discard these items,

please contact your local authorities or dealer

and ask for the correct method of disposal.

Note for the battery symbol (bottom two

symbol examples):

This symbol might be used in combination with

a chemical symbol. In this case it complies

with the requirement set by the Directive for

the chemical involved.

Pb

4

F569021.indb4F569021.indb4 2013/06/079:37:472013/06/079:37:47

Оглавление

Аннотации для Кондиционера Panasonic S71PT2E5 в формате PDF