Panasonic CUPC9GKD: TROUBLESHOOTING

TROUBLESHOOTING: Panasonic CUPC9GKD

ENGLISH

7

TROUBLESHOOTING

The following symptoms do not indicate malfunction.

Symptom Cause

Mist emerges from indoor unit.

Condensation effect due to cooling process.

Waterowingsoundduringoperations.

Refrigerant ow inside the unit.

The room has a peculiar odour.

This may due to damp smell emitted by the wall, carpet, furniture or clothing.

Indoor fan stops occasionally during

This helps to remove the surrounding odours.

automatic fan speed setting.

Operation is delayed a few minutes after

The delay is a protection to the unit’s compressor.

restart.

Outdoor unit emits water/steam.

Condensation or evaporation occurs on pipes.

The unit operates automatically when

It is the Auto Restart function of the unit. Operation will be restarted automatically under the

power is resumed after a power failure.

previous operation mode and airow direction when power is resumed as the operation is

not stopped by remote control .

To cancel the Auto Restart Control, please refer to page 6.

Power indicator blinks before the unit is

This is a preliminary step in preparation for the operation when the ON timer has been set.

switched on.

Check the following before calling for servicing.

Symptom Check

Coolingoperationisnotworkingefciently.

Set the temperature correctly.

Close all doors and windows.

Clean or replace the air lters.

Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

Check if the unit has been installed at an incline.

Close the front panel properly.

Remote control does not work.

Insert the batteries correctly.

Replace weak batteries.

The unit does not work.

Check if the circuit breaker is tripped.

Check if timers have been set.

FOR EXTENDED NON-USE

Activate fan mode for 2~3 hours to thoroughly dry the unit.

Turn off the power supply and unplug.

Remove the remote control batteries.

SEASONAL INSPECTION AFTER EXTENDED

NON-USE

Checking of remote control batteries.

No obstruction at air inlet and air outlet vents.

After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:

Cooling: ≥ 8°C

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:

Abnormal noise during operation.

Water/foreign particles have entered the Remote Control.

Water leaks from Indoor unit.

Circuit breaker switches off frequently.

Power cord becomes unnaturally warm.

Switches or buttons are not functioning properly.

The timer indicator blinks and the unit can not be operated.