Panasonic EY6432FQKW: III. OPERATION

III. OPERATION: Panasonic EY6432FQKW

EY6405(EU).book Page 7 Wednesday, June 15, 2005 7:14 PM

Do not close up vent holes on

III. OPERATION

body sides of the body during

operation.

Switch and Forward / Reverse

Otherwise, the machine function is

lever Operation

adversely affected to cause a fail-

ure

Do NOT strain the tool(motor).

This may cause damage to the

unit.

Use the machine in such a way as

to prevent the air from the body

(Forward ( ), Switch lock, Reverse ( ))

vent holes from blowing directly

CAUTION: Do not operate Forward/Reverse

onto your skin. Otherwise, you

lever until the chuck comes to a com-

may get burnt.

plete stop. Shifting during rotation of

When operating with a Ni-MH bat-

the chuck may damage the tool.

tery pack, make sure the place is

Forward Rotation Switch Operation

well-ventilated.

1. For forward rotation, set the lever to forward.

2. Depress the trigger switch slightly to start the

For Appropriate use of Battery pack

tool slowly.

Ni-MH Battery pack (EY9200/EY9201/

3. The speed increases with the amount of

depression of the trigger for efficient tightening

EY9230/EY9231)

Charge the Ni-MH battery fully before storage

of screws and drilling. The brake operates and

in order to ensure a longer service life.

the chuck stops immediately when the trigger

The ambient temperature range is between

is released.

0°C (32°F) and 40°C (104°F).If the battery

4. After use, set the lever to its center position

pack is used when the battery temperature is

(switch lock).

below 0°C (32°F), the tool may fail to function

Reverse Rotation Switch Operation

properly. In that case, charge the bat¦tery until

1. For reverse rotation, set the lever to reverse.

charging is completed for appropriate function-

Check the direction of rotation before use.

ing of the battery.

2. Depress the trigger switch slightly to start the

When battery pack is not in use, keep it away

tool slowly.

from other metal objects like: paper clips,

3. After use, set the lever to its center position

coins, keys, nails, screws, or other small metal

(switch lock).

objects that can make a connection from one

terminal to another.

Speed Selection

Shorting the battery terminals together may

Choose a low or high speed to suit the use.

cause sparks, burns or a fire.

CAUTION: Check the speed selector switch

When operating with a Ni-MH battery pack,

before use.

make sure the place is well-ventilated.

Clutch Torque Setting

Ni-Cd Battery pack

(EY9106/EY9136)

Adjust the torque to one of the 18 possible set-

Nickel cadmium battery pack requires a

tings or “ ” position to the job.

“BREAK-IN PERIOD” to reach maximum oper-

CAUTION: Test the setting before actual opera-

ating capacity. The “BREAK-IN PERIOD” is

tion. Set the scale at this mark ( ).

accomplished during normal usage during the

(Fig. 7)

first 6-8 charge and discharge cycles of the

Note: When the brake operates, a braking sound

battery pack.

may be heard.

After the “BREAK-IN PERIOD” is completed,

This sound indicates engagement of the bit

the battery pack will maintain maximum operat-

lock.

ing capacity throughout the normal life of the

CAUTION: To eliminate excessive tempera-

battery pack.

ture increase of the tool surface,

do not operate the tool continu-

Battery Pack Life

The rechargeable batteries have a limited life. If the

ously using two or more battery

operation time becomes extremely short after

packs.

recharging, replace the battery pack with a new one.

Tool needs cool off time before

Note: Use under extremely hot or cold conditions

switching to another pack.

will reduce operating capacity per charge.

7