Vitek VT-4201 SR: E N G L I S H
E N G L I S H : Vitek VT-4201 SR
9
E N G L I S H
– dry the lid (8), protection screen (7) and sili-
DELIVERY SET
cone gasket thoroughly;
Multi-cooker (with a lid) – 1 pc.
– place the silicone gasket on the protection
Bowl – 1 pc.
screen (7) and the protection screen (7) - on
Soup ladle – 1 pc.
the lid (8).
Spatula – 1 pc.
• Wipe the surface of the heating element (only
Measuring cup – 1 pc.
when it is cold), do not allow water to get
Instruction manual – 1 pc.
inside the unit body.
• Do not immerse the unit body, power cord
TECHNICAL SPECIFICTAIONS
and plug into the water or other liquids.
Power supply: 220-240 V ~ 50/60Hz
• Clean the multi-cooker body with a damp
Power: 1000-1190 W
cloth and then wipe dry.
Maximal capacity: 6 L
• Do not use abrasive and aggressive deter-
gents for washing of the unit and accessories.
• Keep the multi-cooker away from children in
a dry cool place.
TROUBLES AND TROUBLESHOOTING
Failure Possible Cause Solution
The multi-cooker lid can’t
The silicone gasket or pro-
Remove the protection screen, check
be closed.
tection screen (7) is installed
whether the silicone gasket is installed
improperly.
properly.
The blocking system valve is
Remove the blocking object from the
blocked in the upper position.
valve.
The pressure in the multi-
The blocking system valve (11)
Press the valve on the lid handle and
cooker has been released,
has not moved to the lower
set it down.
but the lid can’t be opened.
position.
Steam is released from
The silicone gasket is not
Switch the unit off, release the pres-
the lid (8) bottom during
installed on the protection
sure in the multi-cooker, open the
cooking.
screen (7).
lid. Place the silicone gasket on the
protection screen (7).
The silicone gasket is very dirty. Clean the silicone gasket.
The silicone gasket is dam-
Replace the silicone gasket.
aged.
The lid (8) is not closed tightly. Close the lid (8) tightly.
Air release through the
The valve is dirty. Switch off the multi-cooker, remove
blocking system valve (11).
the lid and and clean the valve.
The silicone ring of the blocking
Replace the silicone ring of the valve.
system valve is damaged.
The blocking system valve
The pressure control valve (10)
Set the pressure control valve to the
(11) does not go up.
is installed improperly.
position
.
Not enough ingredients or liq-
Follow the recommendations for
uid for steam generation.
amount of products and liquid in the
bowl (6).
Repeated sound signal. The multi-cooker is overheated. Unplug the multi-cooker, open the lid
and let it cool down.
The manufacturer preserves the right to change the specifications of the unit without a preliminary
notification.
VT-4201_IM.indd 9 16.04.2013 17:11:24
Оглавление
- ENGLISH
- E N G L I S H
- ENGLISH
- E N G L I S H
- ENGLISH
- E N G L I S H
- ENGLISH
- D E U T S C H
- DEUTSCH
- D E U T S C H
- DEUTSCH
- D E U T S C H
- DEUTSCH
- D E U T S C H
- DEUTSCH
- русский
- русский
- русский
- русский
- русский
- русский
- русский
- русский
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- ҚазаҚ
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- romÂnĂ/ Moldovenească
- ČESKÝ
- Český
- Český
- Český
- Český
- Český
- Český
- УКРАЇНЬСКИЙ
- Беларусская
- Беларусская
- Беларусская
- Ўзбек
- Ўзбек
- Ўзбек
- Ўзбек
- Ўзбек
- Ўзбек
- Ўзбек