AEG VL 5569 LB: ENGLISH

ENGLISH: AEG VL 5569 LB

ENGLISH

47

Contents

General Safety Instructions

Overview .........................................................................................3

Read the operating instructions carefully before putting

Assembly overview ......................................................................4

the appliance into operation and keep the instructions in-

General Safety Instructions ...................................................47

cluding the warranty, the receipt and, if possible, the box

Children and Frail Individuals ..............................................47

with the internal packing. If you give this device to other

Symbols in these Instructions for Use ..............................47

people, please also pass on the operating instructions.

Special safety instructions .....................................................48

The appliance is designed exclusively for private use

General Instructions ................................................................48

and for the envisaged purpose. This appliance is not

Intended Use ...............................................................................48

it for commercial use. Do not use it outdoors. Keep it

Notes on use ...............................................................................48

away from sources of heat, direct sunlight, humidity

Position ..........................................................................................48

(never dip it into any liquid) and sharp edges. Do not

Overview of the components ................................................48

use the appliance with wet hands. If the appliance is

Assembly accessory overview ...............................................48

humid or wet, unplug it immediately.

Unpacking the Device .............................................................49

When cleaning or putting it away, switch of the appli-

Assembly instructions .............................................................49

ance and always pull out the plug from the socket (pull

Base unit (Fig. a – c) .................................................................49

the plug itself, not the lead) if the appliance is not

Fan (Fig. d)....................................................................................49

being used and remove the attached accessories.

Humidier (Fig. e – f) ..............................................................49

Do not operate the machine without supervision. If

Water ............................................................................................50

you leave the room you should always turn the device

Fill with water ............................................................................50

o. Remove the plug from the socket.

Putting into Service .................................................................50

The device and the mains lead have to be checked

Electrical Connection ..............................................................50

regularly for signs of damage. If damage is found the

Fitting batteries into the remote control ........................50

device must not be used.

Remote control range .............................................................50

Do not try to repair the appliance on your own.

Use .................................................................................................50

Always contact an authorized technician. To avoid

Basic Settings .............................................................................50

the exposure to danger, always have a faulty cable be

Operation .....................................................................................50

replaced only by the manufacturer, by our customer

ON/OFF Switch on/o ......................................................51

service or by a qualiied person and with a cable of the

SPEED Speed ......................................................................51

same type.

TIMER Timer .......................................................................51

Use only original spare parts.

MODE Wind Change Functions ..................................51

Pay careful attention to the following “Special Safety

OSC Oscillation .............................................................51

Instructions“.

MOIST Mist ..........................................................................51

Rell water ..................................................................................51

Children and Frail Individuals

Shutting o ................................................................................51

In order to ensure your children‘s safety, please keep all

Cleaning ......................................................................................51

packaging (plastic bags, boxes, polystyrene etc.) out of

Housing .........................................................................................51

their reach.

Water tank ...................................................................................52

Humidier base..........................................................................52

WARNING!

Troubleshooting ........................................................................52

Caution! Do not allow small children to play with the

Noise development ..................................................................52

foil as there is a danger of suocation!

Technical Data ...........................................................................52

This device is not intended to be used by individuals

Disposal- Meaning of the “Dustbin” Symbol ..................52

(including children) who have restricted physical, sen-

sory or mental abilities and/or insuicient knowl-edge

and/or experience, unless they are supervised by an

individual who is responsible for their safety or have

received instructions on how to use the device.

Children should be supervised at all times in order to

ensure that they do not play with the device.

Symbols in these Instructions for Use

Important information for your safety is specially marked.

It is essential to comply with these instructions in order to

avoid accidents and prevent damage to the machine:

48

ENGLISH

Position

WARNING:

The ideal position is a non-slip, at surface.

This warns you of dangers to your health and indicates

possible injury risks.

Overview of the components

CAUTION:

Overview

This refers to possible hazards to the machine or other

1 Hook

objects.

2 Fastening hooks

NOTE:

3 Propeller

This highlights tips and information.

4 Protection grid

5 Mounting screw M2,5*8mm with nut

6 Switch housing

Special safety instructions

7 Stand tubes

8 Tube with tank cap

Never stick ngers or other objects through the pro-

9 Water tank

tection grid!

10 Humidier base

Watch out for long hair! It can be caught in the fan

11 Stand with cover

owing to the air turbulence!

Use the appliance only with the protection grids on!

Assembly overview

The appliance must be assembled completely before

12 M5*18mm screws

use!

13 Base (Base plate)

Select a stable base to avoid the tipping of the fan

14 Metal plate with mounting holes

during use!

15 M5 nuts

Do not place the device immediately next to stoves or

16 Cover of the stand

other sources of heat.

17 M6*10mm screws with nuts

CAUTION:

18 Motor

The integrated humidier works by ultrasound. This

19 Rear protection grid

sound may be disturbing to pets.

20 Nut for rear protection grid

21 Attachment screw for propeller

22 Front protection grid

General Instructions

Intended Use

Not shown

Remote control

This appliance can be used as a fan and/or humidier.

ST4*25mm screw for fastening the humidier to the

It is intended exclusively for this purpose and may only be

stand

used as such. It may only be used in the manner described

M6 nuts to fasten the motor to the stand tubes

in these instructions for use. The device must not be used

for commercial purposes.

Any other use of this device is considered to be contrary

Assembly accessory overview

to the intended use and may result in damage to materi-

Number Quantity Accessories Size

als or even personal injury.

The rm ETV - Elektro-Technische Vertriebsgesellschaft

5 1 Screw M2,5*8mm

mbH does not accept any liability for damage caused as

5 1 Nut M2,5

a result of the use of this device contrary to its intended

12 4 Screws M5*18mm

use.

14 1 Metal plate

15 4 Nuts M5

Notes on use

17 2 Screws M6*10mm

You can use this appliance to increase the air humidity in

20 1 Nut

a dry environment. This oers the following benets:

21 1 Screw

Provides a healthy indoor environment and is thus

None 1 Screw ST4*25mm

benecial to your well-being.

Your skin does not dry out as readily.

None 2 Nuts M6

Static in the air is eliminated.

The appliance works best if doors and windows are kept

closed when used in mist mode.

ENGLISH

49

Unpacking the Device

Fan (Fig. d)

6. Remove the preinstalled nut (20) from the motor (18).

Remove the device from its packaging.

Keep it close to hand.

Remove all of the packaging material such as foils,

7.

Align the rear protection grid (19) with the motor

lling material, cable holders and cardboard packaging.

recesses (18).

Check the scope of delivery.

NOTE:

NOTE:

The handle must point upwards.

There may still be dust or production residues on the

8. Tighten the nut (20) for the rear

protection grid

clock-

surface of the device. We recommend that you quickly

wise.

wipe of the housing with a damp cloth.

9. Attach the propeller (3). When doing so, use the guide

pin on the motor shaft.

Assembly instructions

10. Tighten the screw (21) for the propeller anti-clockwise.

11. Remove the pretted screw and nut (5) from the front

The appliance must be fully assembled before use! We

protection grid

(22). Keep it close to hand.

recommend that you refer to the gures “Overview” and

12. Open the fastening hooks (2) at the front protection

Assembly overview” when assembling.

grid.

13. Attach the front

protection grid

by engaging the

Base unit (Fig. a – c)

groove of the hook (1) with the rear

protection grid

.

1. Screw the tubes (7) onto the stand (13). Use the four

screws (12), the metal plate (14), and the four nuts (15).

NOTE:

2. Attach the cover of the stand (16) to the stand tubes.

The holes for the screw (5) in the front and rear

protection grid

must be aligned.

NOTE:

14. Secure the

protection grid

with the screw and the nut

The nuts and screws (17) are preinstalled on the rear of

(5).

the switch housing.

15. Close the four fastening hooks (2).

3. Check if the screws (17) possibly have been screwed

into deeply. In this case, turn the screws back a little.

Humidier (Fig. e – f)

Do not screw them out all the way!

The tube already may have been installed on the switch

NOTE:

housing. In this case, continue the assembly from item 18.

If a screw or a bolt should have dropped o, proceed

16. Feed the tube (8) from front to back between the two

as follows:

stand tubes (7). Then insert the tube from the bottom

Hold the preassembled unit (motor (18), switch

upwards through the opening on the underside of the

housing (6), and humidier base (10)) so that the

switch housing (6).

motor points down.

NOTE:

Insert one nut (M6) each into the shaft at the

The end of the tube with the tank cap must be

side of the recesses for the tubes.

positioned at the front above the humidier.

Screw the two screws (17) on the rear of the

switch housing lightly into the nuts.

17. Insert the tube from the back to the front through the

opening on the top of the switch housing.

4. Set the preassembled unit for a depth of approxi-

18. Pull the tube tight so that it lies at against the back

mately 3 cm onto the stand tubes.

of the switch housing.

NOTE:

NOTE:

The humidier cable must be routed between the

The two ends of the tube should have approximately

two tubes.

the same length.

Secure the preassembled unit to the stand tubes by

19. Connect the top end of the tube to the tube connec-

tightening the two screws (17).

tor on the

protection grid

(22).

5. Fasten the base of the humidier (10)

with the large screw (ST4*25mm) to

NOTE:

the base of the stand. For this, insert

The tube above the switch housing must not “sag”.

the screw from below through the

Water which accumulates in the tube prevents the

stand and its cover into the small

formation of the mist. If necessary, push back the

outer bore. (Fig. on the right)

top section of the tube.

20. Place the water tank (9) onto the base of the humidi-

er (10).

50

ENGLISH

21. Fit the tank cap on the bottom end of the tube onto

the water tank. The recess on the tank cap must t

into the groove on the opening to the water tank.

NOTE:

The tank cap on the end of the tube can be

turned.

The water tank must be tted securely to the

base so that mist cannot escape between the

water tank and the base. If necessary tighten the

lower section of the tube.

Water

Only use distilled or boiled, cold tap water without

additives.

CAUTION:

Do not ll the water tank with water from clothes

dryers and water with additives (such as scented oils,

perfume, softeners, or other chemicals). Doing so

may damage the appliance.

Replace the water every 3-4 days, even if it has not yet

been used.

If the appliance has not used for long periods, remove

the water from the water tank and from the base of

the humidier.

Fill with water

Pull the end of the tube with the tank cap out of the

water tank.

Lift the tank from the base of the humidier and turn

it over. The lling hole is located on the bottom of the

tank.

Turn the tank cap and ll the water up to ca. 1 centi-

meter below the rim. The tank holds around 3 litres.

Close the cap again and place the tank back onto the

base.

Place the end of the tube with the tank cap onto the

water tank.

NOTE:

Take note of the recess on the tank cap (see assembly

instruction, item 21).

Putting into Service

Electrical Connection

Before inserting the plug into the socket. Make sure

that the mains voltage to be used matches that of the

device. You can find this information on the nameplate.

Connect the device to a duly installed 230 V~ 50 Hz

protective contact socket. The indicator lamp POWER

shows that the power supply is connected.

Fitting batteries into the remote control

(Batteries not supplied)

Open the lid of the battery compartment on the rear

of the remote control.

Insert 2 MICRO batteries of type R03 “AAA“ 1.5 V.

Please ensure the correct polarity. Details can be found

in the battery compartment.

Close the battery compartment.

NOTE:

If you are not going to use the remote control for a pro-

longed period, remove the batteries in order to prevent

them from leaking.

CAUTION:

Used batteries should not be disposed of in the do-

mestic waste. Please return all batteries to a special

collection point. Your local authority will provide you

with information on this.

Dierent types of battery or new and used batteries

must not be used together.

Remote control range

The remote control has a range of ca. 8 meters. If this

range becomes shorter, the batteries must be changed.

To use the remote control, point it at the sensor on the

front of the switch housing.

Make sure there are no obstacles between the remote

control and the sensor.

The angle of the remote control to the remote control

sensor should not exceed 30° to the right, left, up, and

down.

Use

Basic Settings

Set the blower inclination angle before starting the

device. You can adjust the inclination angle by tipping the

blower casing with both hands.

NOTE:

The inclination angle amounts to approx. 10°.

The tube above the switch housing must not “sag”

due to the inclination of the blower. Water which

collects in the tube prevents the formation of mist.

Operation

You can operate the appliance using the remote control as

well as the buttons on the switch housing. The functions

are identical.

NOTE:

The LED´s on the switch housing indicate the settings.

ENGLISH

51

ON/OFF Switch on/o

Select the NOR (NORMAL) function to return to nor-

Use the ON/OFF button to switch the appliance on or o.

mal operation.

NOTE:

OSC Oscillation

When switching on for the rst time after you have

If you select the OSC function the device oscillates

connected the mains plug to the mains outlet, the

automatically through a range of approximately

fan works in NOR (normal) mode with a low speed

60 degrees.

(LO).

In order to switch the function of, press the OSC

After switching o and on again using the ON/OFF

button again.

button, the appliance continues working in the last

set mode.

MOIST Mist

The humidier can be switched on and o regardless of

SPEED Speed

the fan mode.

Press the SPEED button to select one of the three dier-

Press the MOIST button to select the intensity of the mist:

ent speeds.

LO low

LO low

MI medium

MI medium

HI high

HI high

To deactivate the function, press the MOIST button

again.

TIMER Timer

If you want the timer to switch the device o, press the

Rell water

TIMER button.

When you want to rell the tank:

NOTE:

Switch o the appliance.

Every press of the TIMER button increases the operating

Disconnect the plug from the mains.

time by 30 minutes.

If necessary, pour the remaining water out of the tank.

Maximum shut-o time: 7.5 hours.

Proceed as described under “Fill with water”.

Shutting o

MODE Wind Change Functions

If you want to shut o the fan:

The device has the two special functions: NAT (NATURE)

Switch o the appliance.

and SLE (SLEEP). The speed of the fan buries between the

Disconnect the plug from the mains.

functions.

Empty the water tank and the base of the humidier

Press the MODE button to switch these functions on.

if you do not plan to use the appliance for a lengthy

period.

NAT Natural Mode

- If the HI (high speed) setting is selected, the speed

alternates between high– medium – low – o.

Cleaning

- If you have selected MI (medium speed), the speed

alternates between medium – low – o.

WARNING:

- In the LO (low speed) setting, the speed alternates

Always remove the mains plug before cleaning the

between low - o.

device.

If you need to remove the

protection grid

: Always

SLE Sleep Mode

switch the device of and remove the mains plug.

- If HI speed is set: The fan works in the rst

Under no circumstances should you immerse the

30 minutes as in “Natural Mode” at the HI speed

device in water for cleaning purposes. Otherwise this

setting. In the subsequent 30 minutes the fan

might result in an electric shock or re.

works as in “Natural Mode” at the set MI speed. For

the remaining time the fan works as in “Natural

CAUTION:

Mode” at the speed setting LO.

Do not use a wire brush or any abrasive items.

- If MI speed is set: The fan works for the rst

Do not use any acidic or abrasive detergents.

30 minutes as in “Natural Mode” at the speed set-

ting MI. For the remaining time the fan works as in

Housing

“Natural Mode” at the speed setting LO.

- If LO speed is set: Switching between low speed

Clean the outside of the device with a dry cloth with-

and shut-o of the fan as in “Natural Mode”.

out any additives.

If the device is very dirty wet a cloth with water and

then wipe the device dry once you have inished.

52

ENGLISH

Water tank

Technical Data

Rinse the tank with clean water.

Model: ..................................................................................VL 5569 LB

Allow the tank to dry before closing it again.

Power supply: ....................................................220-240 V~, 50 Hz

If the tank is very dirty, add ca. 100 ml of white vin-

Power consumption: ..................................................................85 W

egar to the cleaning water.

Protection class: .....................................................................................I

Leave the solution in the tank for ca. 10 minutes.

Rinse out the water tank with clean water.

Net weight: ................................................................................3.60 kg

Subject to technical changes without prior notice!

Humidier base

Clean the area on which the water tank rests once a

This device has been tested according to all relevant cur-

week.

rent CE guidelines, such as electromagnetic compatibility

Wipe the area with a damp cloth.

and low voltage directives, and has been constructed in

If necessary, use a few drops of white vinegar and let it

accordance with the latest safety regulations.

act for ca. 5 minutes.

Then wipe the area clean again.

Stubborn dirt can be loosened with a nylon brush.

Troubleshooting

Problem Cause Solution

Disposal- Meaning of the “Dustbin” Symbol

Appliance does

No power supply Check the mains

not work.

outlet.

Protect our environment: do not dispose of electrical

Defective electron-

Seek advice from

equipment in the domestic waste.

ics

a dealer or service

Please return any electrical equipment that you will no

centre.

longer use to the collection points provided for their

The POWER LED

The water tank is

Fill the water

disposal.

and one of the

empty.

tank.

MOIST LED´s (LO/

This helps avoid the potential efects of incorrect disposal

MI/HI) are lit, but

on the environment and human health.

no mist is being

This will contribute to the recycling and other forms of

produced.

reutilisation of electrical and electronic equipment.

Not enough mist

Water has col-

Push the top

Information concerning where the equipment can be

is being produced.

lected in the tube

section of the

disposed of can be obtained from your local authority.

underneath the

tube back so that

switch housing

the water cannot

accumulate.

The humidier is

Clean the humidi-

dirty.

er.

The water is dirty. Change the water.

Mist or water

The bottom section

Pull back the

escapes between

of the tube is too

bottom section of

the water tank

short.

the tube so that

and the humidi-

the water tank

er base.

ts securely on

the base.

There is a bad

The water is too

Change the water

smell.

old or dirty.

and clean the

humidier.

Noise development