AEG OF 2050 E: 22 23 ENGLISH ENGLISH
22 23 ENGLISH ENGLISH: AEG OF 2050 E
TECHNICAL DATA
MAINTENANCE
Rated input ..............................................................................
.......................2050 W
The ventilation slots of the machine must be kept clear at all
-1
No-load speed .........................................................................
..........10000-20000 min
times.
Cage stroke .............................................................................
...........................66 mm
Use only AEG accessories and AEG spare parts. Should
Collet diameter max.................................................................
...................6, 8, 12 mm
components need to be replaced which have not been
Collet diameter max.(UK) ........................................................
........1/4", 3/8", 1/2"
described, please contact one of our AEG service agents
Router diameter .......................................................................
...........................50 mm
(see our list of guarantee/service addresses).
Weight .....................................................................................
..........................6,2 kg
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
Noise/vibration information
printed on the label and order the drawing at your local
Measured values determined according to EN 60 745.
service agents or directly at: AEG Elektrowerkzeuge,
Typically, the A-weighted noise levels of the tool are:
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
Sound power level (K = 3 dB(A)) ............................................
...........................96 dB (A)
Sound pressure level (K = 3 dB(A)) .......................................
.........................107 dB (A)
SYMBOLS
Wear ear protectors!
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Please read the instructions carefully before
2
Vibration emission value a
h
...................................................
.............................7 m/s
starting the machine.
2
Uncertainty K ........................................................................
..........................1,5 m/s
WARNING
Always disconnect the plug from the socket
before carrying out any work on the machine.
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase
the exposure level over the total working period.
Accessory - Not included in standard equipment,
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
available as an accessory.
when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
WARNING! Read all safety warnings and all
The dust that arises when working with this tool can be
electrical and electronic equipment and its
instructions, including those given in the accompanying
detrimental to health (e.g. when working oak or bECh wood,
implementation in accordance with national law,
brochure. Failure to follow the warnings and instructions
stones, paint, which could contain lead or other harmful
electric tools that have reached the end of their
may result in electric shock, re and/or serious injury.
chemicals) and therefore not reach the body. Use a dust
life must be collected separately and returned to
Save all warnings and instructions for future reference.
absorption system and wear a suitable dust protection
an environmentally compatible recycling facility.
mask. Remove deposited dust thoroughly, e.g. with a
SAFETY INSTRUCTIONS
vacuum cleaner.
Wear ear protectors. Exposure to noise can cause hearing
Under the effect of extreme electromagnetic interferences
loss.
from the outside, temporary variations in the speed of
rotation could arise in particular cases.
Appliances used at many different locations including open
air must be connected via a residual current operated
SPECIFIED CONDITIONS OF USE
device (FI, RCD, PRCD).
The router can be used for rabbeting, rounding off,
Always wear goggles when using the machine. It is
chamfering, routing of edges, as well as pitting in wood and
recommended to wear gloves, sturdy non slipping shoes
plastic.
and apron.
Do not use this product in any other way as stated for
Always disconnect the plug from the socket before carrying
normal use.
out any work on the machine.
Only plug-in when machine is switched off.
EC-DECLARATION OF CONFORMITY
Keep mains lead clear from working range of the machine.
We declare under our sole responsibility that this product is
Always lead the cable away behind you.
in conformity with the following standards or standardized
Never reach into the danger area of the plane when it is
documents. EN 60745, EN 55014-1, EN 55014-2,
running.
EN 61000-3-2, EN 61000-3-3, in accordance with the
regulations 98/37/EC, 2004/108/EC
Always use the protective shields on the machine.
Only use tools whose permitted speed is at least as high as
the highest no-load speed of the machine.
Sawdust and splinters must not be removed while the
Winnenden, 2008-12-01
Rainer Kumpf
machine is running.
Manager Product Development
Only use professionally grinded router cutters.
MAINS CONNECTION
Only use router cutter with correct shank diameter.
Connect only to single-phase a.c. current and only to the
The workpieces should be clamped down before cutting.
system voltage indicated on the rating plate. It is also
Put the router back to original position after usage (loosen
possible to connect to sockets without an earthing contact
clamping lever to secure cage).
as the design conforms to safety class II.
Only move the workpiece in counter rotation to cutter (only
work oppositely oriented)! For security, use devices such as
safety- and pressure device, guide slide, rip fence, etc.
22 23
ENGLISH
ENGLISH
Оглавление
- 2 3
- STOP START
- 6 7
- 8 9
- 10 11
- 12 13
- 14 15
- 16 17
- 18 19
- 20 21
- 22 23 ENGLISH ENGLISH
- 24 25 DEUTSCH DEUTSCH
- 26 27 FRANÇAIS FRANÇAIS
- 28 29 ITALIANO ITALIANO
- 30 31 ESPAÑOL ESPAÑOL
- 32 33 PORTUGUES PORTUGUES
- 34 35 NEDERLANDS NEDERLANDS
- 36 37 DANSK DANSK
- 38 39 NORSK NORSK
- 40 41 SVENSKA SVENSKA
- 42 43 SUOMI SUOMI
- 44 45 ÅËËÇNÉÊÁ ÅËËÇNÉÊÁ
- 46 47 TÜRKÇE TÜRKÇE
- 48 49 ČESKY ČESKY
- 50 51
- 52 53 POLSKI POLSKI
- 54 55 MAGYAR MAGYAR
- 56 57 SLOVENSKO SLOVENSKO
- 58 59 HRVATSKI HRVATSKI
- 60 61 LATVISKI LATVISKI
- 62 63
- 64 65 EESTI EESTI
- 66 67 ÐÓÑÑÊÈÉ ÐÓÑÑÊÈÉ
- 68 69 БЪЛГАÐÑÊÈ БЪЛГАÐÑÊÈ
- 70 71 ROMÂNIA ROMÂNIA
- 72 73 МАКЕДОНСКИ МАКЕДОНСКИ
- 74 75 中文 中文