AEG KH 5 E 412326: 18 19 ENGLISH ENGLISH

18 19 ENGLISH ENGLISH: AEG KH 5 E 412326

TECHNICAL DATA

MH 5 E KH 5 E

SPECIFIED CONDITIONS OF USE

SYMBOLS

Rated input ..............................................................................

.......................1200 W .........................1200 W

KH 5 E: The pneumatic hammer can be universally used for

Output ......................................................................................

.........................600 W ...........................600 W

hammer drilling and chiselling in stone and concrete.

-1

Please read the instructions carefully before

No-load speed .........................................................................

............................... ..............................450 min

-1

MH 5 E: The hammer can be used for chiselling in stone

starting the machine.

Speed under load max. ...........................................................

............................... ..............................450 min

-1

-1

and concrete.

Rate of percussion under load max. ........................................

.......................2840 min

.....................2840 min

Single impact strength Drilling/Chiselling ................................

.........................-/13 J .......................... 11/13 J

Do not use this product in any other way as stated for

Drilling capacity in concrete .....................................................

............................... ................................40 mm

normal use.

Always disconnect the plug from the socket

Tunnel bit in concrete, bricks and limestone ...........................

............................... ................................65 mm

before carrying out any work on the

Core cutter in concrete, bricks and limestone .........................

............................... ................................90 mm

EC-DECLARATION OF CONFORMITY

machine.

Chuck neck diameter ...............................................................

...........................66 mm ..........................66 mm

We declare under our sole responsibility that this product is

Weight without cable ...............................................................

..........................6,2 kg ............................6,6 kg

in conformity with the following standards or standardized

E

documents: EN 60745, EN 55014-1, EN 55014-2,

Measured values determined according to EN 60 745.

EN 61000-3-2, EN 61000-3-3, in accordance with the

Accessory - Not included in standard

regulations 98/37/EC, 2004/108/EC, 2000/14/EC (MH 5 E)

equipment, available as an accessory.

Typically, the A-weighted noise levels of the tool are:

Sound pressure level (K = 3 dB(A)) .......................................

............................... ................................96 dB (A)

Sound power level (K = 3 dB(A)) ............................................

............................... ..............................107 dB (A)

Wear ear protectors!

Do not dispose of electric tools together

E

Winnenden, 2007-05-02

Rainer Kumpf

with household waste material! In

Typically the A-weighted sound pressure level of the

Manager Product Development

observance of European Directive 2002/96/

tool is .......................................................................................

...........................91 dB (A)

EC on waste electrical and electronic

Measured values determined according to 2000/14/EG at the

equipment and its implementation in

user’s ear.

MAINS CONNECTION

accordance with national law, electric tools

2000/14/EC: Conformity assessment procedure according to

that have reached the end of their life must

Connect only to single-phase a.c. current and only to the



be collected separately and returned to an

system voltage indicated on the rating plate. It is also



environmentally compatible recycling

possible to connect to sockets without an earthing contact

63069 Offenbach, Germany

facility.

as the design conforms to safety class II.

Measured sound power level ................................................

.........................101 dB (A)

Guaranteed sound power level .............................................

.........................104 dB (A)

Wear ear protectors!

MAINTENANCE



The ventilation slots of the machine must be kept clear at all

Total vibration values (vector sum in the three axes)

times.

determined according to EN 60745.

Important note! If the carbon brushes are worn, in addition

Vibration emission value a

:

h

to exchanging the brushes the tool should be sent to

2

Hammer-drilling in concrete: vibration emission value a

.......

............................... ................................13 m/s

h

after-sales service. This will ensure long service life and top

2

Uncertainty K = .......................................................................

............................... ...............................1,5 m/s

performance.

2

2

Chiselling: vibration emission value a

....................................

........................ 11,5 m/s

............................9 m/s

h

2

2

Uncertainty K = .......................................................................

..........................1,9 m/s

.........................1,9 m/s

Use only AEG accessories and AEG spare parts. Should

components need to be replaced which have not been

described, please contact one of our AEG service agents

(see our list of guarantee/service addresses).

WARNING

The vibration emission level given in this information sheet has been measured in accordance with a standardized test given

If needed, an exploded view of the tool can be ordered.

in EN 60745 and may be used to compare one tool with another.

Please state the Article No. as well as the machine type

printed on the label and order the drawing at your local

The vibration emission level will vary because of the ways in which a power tool can be used and may increase above the

service agents or directly at: AEG Elektrowerkzeuge,



Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

in such a way.

Note: To be accurate, an estimation of the level of ex-posure to vibration experienced during a given period of work should

also take into account the times when the tool is switched off and when it is running but not actually doing the job. This may



SAFETY INSTRUCTIONS

Always disconnect the plug from the socket before carrying

out any work on the machine.

Please pay attention to the safety instructions in the



Only plug-in when machine is switched off.

Wear ear protectors. Exposure to noise can cause hearing

Keep mains lead clear from working range of the machine.

loss.

Always lead the cable away behind you.

Loss of



control can cause personal injury.

electric cables and gas or waterpipes.



The dust produced when using this tool may be harmful to



health. Do not inhale the dust. Wear a suitable dust

Cutting

protection mask.

accessory contacting a „live“ wire may make exposed metal

parts of the power tool „live“ and shock the operator.

Appliances used at many different locations including open

air should be connected via a residual current device of

30 mA or less.

Always wear goggles when using the machine. It is

recommended to wear gloves, sturdy non slipping shoes

and apron.

Sawdust and splinters must not be removed while the

machine is running.

18 19

ENGLISH

ENGLISH