AEG KH5G 4935418160: инструкция
Раздел: Строительство и ремонт
Тип: Сетевой перфоратор
Характеристики, спецификации
Инструкция к Сетевому перфоратору AEG KH5G 4935418160
KH
5
G
English
5
Deutsch
7
Français
9
Italiano
11
Español
13
Português
15
Nederlands
17
Dansk
19
Norsk
21
Svenska
23
Suomi
25
Ελληνικά
27
Türkçe
29
Česky
31
Slovensky
33
Polski
35
Magyar
37
Slovensko
39
Hrvatski
41
Latviski
43
Lietuviškai
45
Eesti
47
Òåõíè÷åñêèå äàííûå, Ðåêîìåíäàöèè ïî òåõíèêå áåçîïàñíîñòè,
Pусский
Èñïîëüçî- âàíèå, Ïîäêëþ÷åíèå ê ýëåêòðîñåòè, Îáñëóæèâàíèå, Ñèìâîëû
49
Òåõíè÷åñêè äàííè, Ñïåöèàëíè óêàçàíèÿ çà áåçîïàñíîñò, Èçïîëçâàíå ïî ïðåäíàçíà÷åíèå,
Български
ÑÅ-Äåêëàðàöèÿ çà ñúîòâåòñòâèå, Ñâúðçâàíå êúì ìðåæàòà, Ïîääðúæêà, Ñèìâîëè
51
Română
53
Òåõíè÷êè Ïîäàòîöè, Óïàòñòâî Çà Óïîòðåáà, Ñïåöèôèöèðàíè Óñëîâè Íà
Мaкeдohcки
Óïîòðåáà, Åó-äåêëàðàöè¼à Çà Ñîîáðàçíîñò, БАТЕРИИ, Îäðæóâàњå, Ñèìáîëè
55
技术数据, 特殊安全指示, 正确地使用机器, 电源插头, 蓄电池, 维修, 符号 请详细阅读并妥善保存!
中文
57
II
I
III
Accessory
IV
V
Zubehör
Accessoires
Accessorio
Accessorio Acessório
0
Toebehoren
Tilbehør
Tilbehør
Tillbehör
Lisälaite
Εξαρτήματα
Aksesuar
Příslušenství
Príslušenstv
Wyposażenie
Azokat a tartozékokat
Oprema
Piederumi
Priedas
Tarvikud
Äîïîëíèòåëü
Аксесоари
Accesoriu
ополнителна
опрема
配件
1.
2.
III
I
3.
1
1.
II
II
2.
TEST
1
2
2
Start
Stop
III
III
3
0
0
IV
II
4
TECHNICAL DATA
KH5G
Rotary Hammer
Production code 4181 61 01...
... 000001-999999
Rated input 1100 W
Output 550 W
-1
No-load speed 450 min
-1
Speed under load max. 430 min
-1
Rate of percussion under load max. 3000 min
Impact energy per stroke according to EPTA-Procedure 05/2009, Drilling / Chiselling 7,5 / 7,5 J
Impact energy per stroke (pre 2009), Drilling / Chiselling 9,0 / 9,0 J
Drilling capacity in concrete 40 mm (SDS-max)
Tunnel bit in concrete, bricks and limestone 65 mm (SDS-max)
Core cutter in concrete, bricks and limestone 105 mm (SDS-max)
Chuck neck diameter 66 mm
Weight according EPTA-Procedure 01/2003 6,4 kg
GB
Noise/Vibration Information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A)) 93,0 dB (A)
Sound power level (K=3dB(A)) 104,0 dB (A)
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to EN 60745.
Vibration emission value a
h
2
Hammer-drilling in concrete:
16,8 m/s
2
Uncertainty K =
1,5 m/s
2
Chiselling:
16,7 m/s
2
Uncertainty K =
1,5 m/s
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745 and
may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for dierent applications, with
dierent accessories or poorly maintained, the vibration emission may dier. This may signicantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched o or when it is running
but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the eects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all instruc-
Hold power tool by insulated gripping surfaces, when
tions, including those given in the accompanying brochure.
performing an operation where the cutting accessory may
Failure to follow the warnings and instructions may result in electric
contact hidden wiring or its own cord. Cutting accessory
shock, re and/or serious injury.
contacting a „live“ wire may make exposed metal parts of the power
tool „live“ and could give the operator an electric shock.
Save all warnings and instructions for future reference.
Appliances used at many dierent locations including open air should
SAFETY INSTRUCTIONS
be connected via a residual current device (FI, RCD, PRCD) of 30mA
or less.
Wear ear protectors. Exposure to noise can cause hearing loss.
Always wear goggles when using the machine. It is recommended to
Use auxiliary handle(s), if supplied with the tool. Loss of
wear gloves, sturdy non slipping shoes and apron.
control can cause personal injury.
Sawdust and splinters must not be removed while the machine is
running.
English
5
Before doing any work on the machine, pull the plug out of the
SYMBOLS
socket.
Only plug-in when machine is switched o.
Please read the instructions carefully before
Keep mains lead clear from working range of the machine. Always
starting the machine.
lead the cable away behind you.
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or oor, take care to avoid electric
CAUTION! WARNING! DANGER!
cables and gas or waterpipes.
The dust produced when using this tool may be harmful to health.
Do not inhale the dust. Use a dust absorption system and wear a
Always disconnect the plug from the socket before
suitable dust protection mask. Remove deposited dust thoroughly,
carrying out any work on the machine.
e.g. with a vacuum cleaner.
SPECIFIED CONDITIONS OF USE
Accessory - Not included in standard equipment,
available as an accessory.
The rotary hammer can be universally used for hammer drilling and
chiselling in stone and concrete.
Do not dispose of electric tools together with
Do not use this product in any other way as stated for normal use.
household waste material! In observance of
European Directive 2002/96/EC on waste electrical
ECDECLARATION OF CONFORMITY
and electronic equipment and its implementation
GB
We declare under our sole responsibility that the product described
in accordance with national law, electric tools that
under “Technical Data” fullls all the relevant regulations and the
have reached the end of their life must be collected
directives 2011/65/EU (RoHs), 2004/108/ EC, 2006/42/EC and the
separately and returned to an environmentally
following harmonized standards have been used:
compatible recycling facility.
EN 60745-1:2009 + A11:2010
Class II construction, tool in which protection
EN 60745-2-6:2010
against electric shock does not rely on basic
EN 55014-1:2006 + A1:2009 + A2:2011
insulation only, but in which additional safety
EN 55014-2:1997 + A1:2001 + A2:2008
precautions, such as double insulation or reinforced
EN 61000-3-2:2006 + A1:2009 + A2:2009
insulation, are provided.
EN 61000-3-3:2008
Winnenden, 2013-06-14
Alexander Krug / Managing Director
Authorized to compile the technical le
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
MAINS CONNECTION
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect to
sockets without an earthing contact as the design conforms to safety
class II.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
Use only AEG accessories and spare parts. Should components need to
be replaced which have not been described, please contact one of our
AEG service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the machine type printed as well as the six-digit No. on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße10, 71364Winnenden,
Germany.
English
6