TECHNICAL DATA
BE 705 R
Power screwdriver
Production code 4165 06 01...
... 000001-999999
Rated input 705 W
Output 566 W
-1
No-load speed 2700 min
-1
Speed under load max. 1820 min
Static jamming moment * 15 Nm
Drilling capacity in steel 10 mm
Drilling capacity in Aluminium 16 mm
Drilling capacity in wood 30 mm
Drill chuck range 1-10 mm
Drive shank 1/2 ˝
Weight according EPTA-Procedure 01/2003 1,6 kg
Noise/Vibration Information
GB
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A))
85 dB(A)
Sound power level (K=3dB(A))
96 dB(A)
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to EN 60745.
Drilling into metal:
2
Vibration emission value a
<2,5 m/s
h
2
Uncertainty K=
1,5 m/s
Screwing:
2
Vibration emission value a
<2,5 m/s
h
2
Uncertainty K=
1,5 m/s
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745 and
may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for dierent applications, with
dierent accessories or poorly maintained, the vibration emission may dier. This may signicantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched o or when it is running
but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the eects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Hold power tool by insulated gripping surfaces, when
WARNING! Read all safety warnings and all instructions,
performing an operation where the cutting accessory may
including those given in the accompanying brochure. Failure
contact hidden wiring or its own cord. Cutting accessory
to follow the warnings and instructions may result in electric shock,
contacting a „live“ wire may make exposed metal parts of the power
re and/or serious injury.
tool „live“ and could give the operator an electric shock.
Save all warnings and instructions for future reference.
Hold power tool by insulated gripping surfaces, when perfor-
SAFETY INSTRUCTIONS
ming an operation where the fastener may contact hidden
wiring or its own cord. Fasteners contacting a „live“ wire may
Wear ear protectors. Exposure to noise can cause hearing loss.
make exposed metal parts of the power tool „live“ and could give the
Use auxiliary handle(s), if supplied with the tool. Loss of
operator an electric shock.
control can cause personal injury.
English
6

Appliances used at many dierent locations including open air should
MAINTENANCE
be connected via a residual current device (FI, RCD, PRCD) of 30mA
or less.
The ventilation slots of the machine must be kept clear at all times.
Use protective equipment. Always wear safety glasses when working
It is recommended to regularly use cleaner for the clamping jaws and
with the machine. The use of protective clothing is recommended,
the clamping jaw borings.
such as dust mask, protective gloves, sturdy non-slip footwear,
Use only AEG accessories and spare parts. Should components need to
helmet and ear defenders.
be replaced which have not been described, please contact one of our
Sawdust and splinters must not be removed while the machine is
AEG service agents (see our list of guarantee/service addresses).
running.
If needed, an exploded view of the tool can be ordered. Please state
Before doing any work on the machine, pull the plug out of the
the machine type printed as well as the six-digit No. on the label
socket.
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße10, 71364Winnenden,
Only plug-in when machine is switched o.
Germany.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
SYMBOLS
When working in walls ceiling, or oor, take care to avoid electric
cables and gas or waterpipes.
Please read the instructions carefully before starting
the machine.
The dust produced when using this tool may be harmful to health. Do
not inhale the dust. Wear a suitable dust protection mask.
SPECIFIED CONDITIONS OF USE
CAUTION! WARNING! DANGER!
GB
The drill/screwdriver can be universally used for drilling, and
Always disconnect the plug from the socket before
screwdriving.
carrying out any work on the machine.
Do not use this product in any other way as stated for normal use.
Accessory - Not included in standard equipment,
ECDECLARATION OF CONFORMITY
available as an accessory.
We declare under our sole responsibility that the product described
Do not dispose of electric tools together with
under “Technical Data” fullls all the relevant regulations and the
household waste material! In observance of European
directives 2011/65/EU (RoHs), 2004/108/ EC, 2006/42/EC and the
Directive 2002/96/EC on waste electrical and electronic
following harmonized standards have been used:
equipment and its implementation in accordance with
EN 60745-1:2009 + A11:2010
national law, electric tools that have reached the end
EN 60745-2-1:2010
of their life must be collected separately and returned
EN 60745-2-2:2010
to an environmentally compatible recycling facility.
EN 55014-1:2006 + A1:2009 + A2:2011
Class II construction, tool in which protection against
EN 55014-2:1997 + A1:2001 + A2:2008
electric shock does not rely on basic insulation only,
EN 61000-3-2:2006 + A1:2009 + A2:2009
but in which additional safety precautions, such
EN 61000-3-3:2008
as double insulation or reinforced insulation, are
provided.
Winnenden, 2013-06-13
Alexander Krug / Managing Director
Authorized to compile the technical le
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
MAINS CONNECTION
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.
English