Insert rawlplugs into the holes.

Assembly instructions

Please use two screws of size 4 x 25 mm. Allow the

The device must be completely assembled before use!

screws to protrude 10 – 12 mm out of the wall.

While reading the text it is advisable to refer to the

Suspend the switch housing by the screws. Check

„Overview of the Components“ (Illustration B).

that it is  rmly held in place.

1. Insert the switch housing (12) into the stand (11).

Putting into Service

Attach it on the bottom with the crosshead screw

(Illustration A).

Electrical Connection

2. Position the rear protection grid (7) in place in ac-

cordance with the recesses.

1. Before inserting the plug into the socket. Make sure

that the mains voltage to be used matches that of

NOTE:

the device. You can  nd this information on the

Please ensure that the carrying handle is facing

nameplate.

upwards.

2. Connect the device to a duly installed 230V/50Hz

3. Turn the attachment ring (6) for the rear protection

protective contact socket.

grid (7) slightly in a clockwise direction.

4. Attach the propeller. Note the position of the guide

Use

pin on the motor shaft.

5. Tighten the attachment screw (4) for the propeller in

Basic Settings

an anticlockwise direction.

6. Insert the front protective grille (1).

Set the blower inclination angle before starting the

device.

NOTE:

In order to do this, release the wing screw (14) and

Ensure that the holes for the attachment screw in

move the fan to the desired position.

the front and rear protective grille are aligned one

Retighten the wing screw by hand.

above the other

.

7. Tighten the protective grille with the attachment

NOTE:

screw (2) supplied.

The stopper prevents the fan from falling over.

8. Close the attachment hooks (3).

Operation

Position

Use the pushbutton switches on the front to select the

The ideal position is a non-slip,  at surface.

speed:

1 = slow, 2 = medium, 3 = fast.

Wall Installation

Shift to „0“ to switch o the device.

You can also install the fan on the wall. Please remember

Blower Direction/Oscillation

that there must be an electric socket close by.

You can choose from the two following options:

Setting up the Fan (Illustration C)

1.

The device must have been switched o before. The

1. Release the wing screw (14) on the joint.

setting knob must be pulled out.

2. Remove the stopper (13) by loosening the screw.

T

urn the device carefully with by hand by holding the

3. Turn the motor through 90°.

fan on the sides and turning it either to the left or to

4. Turn the wing screw until it is hand-tight.

the right until the limit stop

.

Attachment to the Wall (Illustration. D)

CAUTION: do not exceed this limit.

On the underside of the switch housing there are two

2. Select the automatic swinging direction by pressing

indentations. The distance between these indentations

in the knob. The device swings automatically within

is 46 mm.

a range of 90°. This function is active only when the

fan is on. To deactivate the function pull out the set-

Drill two horizontal holes at this distance.

ting knob.

CAUTION:

Please ensure beforehand that you will not be

damaging any pipes or electric wires concealed in

the wall!

05-VL 5529 AEG.indd 2405-VL 5529 AEG.indd 24 02.12.2008 10:13:18 Uhr02.12.2008 10:13:18 Uhr