Samsung NX-308: PROGRAMMING SECTION

PROGRAMMING SECTION: Samsung NX-308

PROGRAMMING

SECTION

4Programming 1999.9.15 12:42 PM 페이지1

4Programming 1999.9.15 12:42 PM 페이지2

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

TABLE OF CONTENTS

PROGRAMMING

1. INTRODUCTION TO PROGRAMMING ................................ 4-1

1.1 PROGRAMMING OVERVIEW ................................................... 4-1

1.2 PROGRAMMING LEVELS......................................................... 4-1

1.3 PROGRAM KEYS ...................................................................... 4-2

1.3.1 NX keyset with LCD ............................................................................. 4-2

1.3.2 Other LCD keysets .............................................................................. 4-3

2. PROGRAMMING PROCEDURES.......................................... 4-4

2.1 PROGRAM LIST IN NUMERICAL ORDER................................ 4-4

2.2 PROGRAM LIST IN ALPHABETICAL ORDER.......................... 4-5

2.3 PROGRAM PROCEDURES ...................................................... 4-6

4Programming 1999.9.15 12:42 PM 페이지3

4Programming 1999.9.15 12:42 PM 페이지4

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

NOTICE

this manual describes stadard setting. Some MMC Codes and

default data may be different from those shown depending on

the country.

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

1. INTRODUCTION TO PROGRAMMING

1.1 PROGRAMMING OVERVIEW

The system arrives from the factory with default data entered. Connect it to

trunks, stations, and power, turn the system on and it is fully operational. The

only thing left to do is customize the data to fit the customer's needs. This is

called programming the system.

MMC stands for Man Machine Code, and each program is assigned a different

two digit code. MMCs are used to view, create, or change customer data.

Programming is simply deciding what needs to be done and knowing which

MMC is used to do it.

System programming may be done from any NX-24E or NX-12E keyset (Refer to

1.3.1) or any keyset with LCD (Refer to 1.3.2). The first thing to is open system

programming. As a security measure, a passcode must be known to do this.

1.2 PROGRAMMING LEVELS

There are three levels of programming: SYSTEM, CUSTOMER and STATION.

System and Customer levels are under passcode protection while station

programming does not require a passcode.

To prevent conflicting data from being entered, only one person at a time can

enter programming with the technician or customer passcode. While

programming is in progress, normal system operation is not affected.

SYSTEM LEVEL

This level is entered via MMC 20 and requires the Technician Level passcode.

It allows access to all system, station, and maintenance programs.

CUSTOMER LEVEL

This level is entered via MMC 20 and requires the Customer passcode. It allows

access to station and system programs assigned by the Technician Level in

MMC 90. When using the customer passcode to access station programs, data

for all stations can be viewed or changed.

STATION LEVEL

All keysets can access station programs 10 through 17 without using a

passcode. Each user can only change data for his/her own keyset.

4 - 1

4Programming 1999.9.15 12:42 PM 페이지5

4Programming 1999.9.15 12:42 PM 페이지6

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

1.3 PROGRAM KEYS

1.3.1 NX-keyset with LCD

1X16 LCD

Display

P r o g r a m m a b l e

Butterns

KEYPAD

Used to enter

data

VOLUME (+) or (-) : Used to scroll through stations or trunks.

MUTE or MESSAGE : Usually used to select data.

TRANSFER : Used to enter the programming mode.

Also used to save changes and exit the program.

SPEAKER : Used to save changes and advance to the next

program.

HOLD : Usually used to clear previous data.

4 - 2

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

1.3.2 Other LCD keysets

When the using other types of LCD keysets, such as the AS-30 or 816,

programming key assignments will differ from the NX model, as shown in

the box below.

AS-Keyset NX-keyset 816 keyset

TRSF/ALM TRANSFER AUTO RDL

N/A SPEED ALM/SD

RD REDIAL RD

FLASH FLASH BOSS/SECR

N/A CALLBACK CONF

PAGE PAGE PAGE

FUNC/DND MUTE MUTE/DND

MSG MESSAGE MSG

SPK SPEAKER SPK

HOLD HOLD HOLD

VOLUME VOLUME (-)/(+) TIMER/AUTO ANS

4 - 3

4Programming 1999.9.15 12:42 PM 페이지7

4Programming 1999.9.15 12:42 PM 페이지8

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

2. PROGRAMMING PROCEDURES

2.1 PROGRAM LIST IN NUMERICAL ORDER

00: STATION LOCK 45: TRUNK GROUP

01: CHANGE STATION PASSCODE 46: ASSIGN DISA LINE

10: SET ANSWER MODE 50: SYSTEM TIMERS

11: CALL FORWARD 51: TONE/RING CADENCE

12: STATION ON/OFF 52: SYSTEM WIDE COUNTER

13: SET RING FREQUENCY 53: TRUNK WIDE TIMERS

14: STATION NAMES 54: MAKE/BREAK RATIO

15: DATE DISPLAY 55: CURRENT DATE AND TIME

16: KEY EXTENDER 56: ASSIGN AUTO NIGHT TIME

17: STATION SPEED-DIAL 57: CALL COST

20: OPEN PROGRAMMING 60: TOLL DENY TABLE/APPLY

21: CHANGE PASSCODE 61: TOLL ALLOW TABLE/APPLY

22: CUSTOMER ON/OFF 62: PBX ACCESS CODE

23: PAGE ZONE 63: AUTHORIZATION TABLE

24: ASSIGN BARGE-IN 64: OVERRIDE TABLE

25: HOT/WARM LINE 65: ASSIGN WILD CHARACTER

26: ALARM REMINDER 66: SYSTEM SPD-DIAL TOLL RESTRICTION

27: VACANT MESSAGE 67: ASSIGN SYSTEM SPEED-DIAL

28: CALL DISC RESTRICTION

30: STATION TOLL CLASS 70: DIAL NUMBERING PLAN

31: EXT/TRK USE 71: SYSTEM KEY PROGRAMMING

32: INTERCOM USE 72: STATION KEY PROGRAMMING

33: ASSIGN DOOR RING 73: KEY TEST

34: ASSIGN PICKUP GROUP

35: ASSIGN STATION GROUP 80: SYSTEM I/O PARAMETERS

36: ASSIGN BOSS/SECRETARY 81: SMDR OPTIONS

37: ASSIGN ADD-ON MODULE 83: CALL TRAFFIC

38: SLT DIALING TYPE

39: DATA LINE 90: CUSTOMER USE MMC

91: SYSTEM VERSION

40: C.O./PBX LINE 92: PORT STATUS

41: TRUNK DIALING TYPE 93: LANGUAGE SELECTION

42: TRUNK ON/OFF 94: HALT PROCESS

43: ASSIGN TRUNK RING 95: SYSTEM RESTART

44: TRUNK NAMES

4 - 4

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

2.2 PROGRAM LIST IN ALPHABETICAL ORDER

ALARM REMINDER 26 LANGUAGE SELECTION 93

ASSIGN ADD-ON MODULE 37 MAKE/BREAK RATIO 54

ASSIGN AUTO NIGHT TIME 56 OPEN PROGRAMMING 20

ASSIGN BARGE-IN 24 OVERRIDE TABLE 64

ASSIGN BOSS/SECRETARY 36 PAGE ZONE 23

ASSIGN DISA LINE 46 PBX ACCESS CODE 62

ASSIGN DOOR RING 33 PORT STATUS 92

ASSIGN PICKUP GROUP 34 SET ANSWER MODE 10

ASSIGN STATION GROUP 35 SET RING FREQUENCY 13

ASSIGN SYSTEM SPEED-DIAL 67 SLT DIALING TYPE 38

ASSIGN TRUNK RING 43 SMDR OPTIONS 81

ASSIGN WILD CHARACTER 65 STATION KEY PROGRAMMING 72

AUTHORIZATION TABLE 63 STATION LOCK 00

C.O./PBX LINE 40 STATION NAMES 14

CALL COST 57 STATION ON/OFF 12

CALL DISC 28 STATION SPEED-DIAL 17

CALL FORWARD 11 STATION TOLL CLASS 30

CALL TRAFFIC 83 SYSTEM I/O PARAMETERS 80

CHANGE PASSCODE 21 SYSTEM KEY PROGRAMMING 71

CHANGE STATION PASSCODE 01 SYSTEM RESTART 95

CURRENT DATE AND TIME 55 SYSTEM SPD-DIAL TOLL RESTRICTION 66

CUSTOMER ON/OFF 22 SYSTEM TIMERS 50

CUSTOMER USE MMC 90 SYSTEM VERSION 91

DATA LINE 39 SYSTEM WIDE COUNTER 52

DATE DISPLAY 15 TOLL ALLOW TABLE/APPLY 61

DIAL NUMBERING PLAN 70 TOLL DENY TABLE/APPLY 60

EXT/TRK USE 31 TONE/RING CADENCE 51

HALT PROCESS 94 TRUNK DIALING TYPE 41

HOT/WARM LINE 25 TRUNK GROUP 45

INTERCOM USE 32 TRUNK NAMES 44

KEY EXTENDER 16 TRUNK ON/OFF 42

KEY TEST 73 TRUNK WIDE TIMERS 53

VACANT MESSAGE 27

4 - 5

4Programming 1999.9.15 12:42 PM 페이지9

4Programming 1999.9.15 12:42 PM 페이지10

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

2.3 PROGRAM PROCEDURES

The following instructions for each MMC assume that you have already opened

programming.

To open SYSTEM (CUSTOMER) PROGRAMMING:

Technician Passcode

(default:4321)

OR

Customer Passcode

(default:1234)

When finished programming MMCs 00 through 95 and have other programming

to do, press [SPEAKER] to exit the MMC and stay in the programming mode.

Then perform one of the following operations:

1) Dial another MMC code directly and continue programming.

2) Press [VOLUME](+) and (-) keys to scroll through all MMC codes. When the

desired MMC code is reached, press [SPEAKER] and continue programming.

Pressing [ T R A N S F E R ] will always save changes and exit the programming

mode.

4 - 6

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 00 STATION LOCK

Use this MMC to lock or unlock stations in order to control others using your

station.

UNLOCK Normal status

LOCKED1 Prohibit another user from making outside call.

LOCKED2 Prohibit another user from dialing or receiving any calls.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 00

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to make selections

OR

Using KEYPAD, dial

0 for UNLOCKED

1 for LOCKED1

or 2 for LOCKED2

4. Press [TRANSFER] to save and exit

DEFAULT DATA

UNLOCKED

RELATED MMC

MMC 01 CHANGE USER PASSCODE

4Programming 1999.9.15 12:42 PM 페이지11

4Programming 1999.9.15 12:42 PM 페이지12

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 01 CHANGE STATION PASSCODE

This MMC is used to reset any keyset's passcode to its default value of '1234',and cannot

display station passcodes.

Keyset users can set or change their individual passcodes, which are used to lock or

unlock the keyset and to access the WALKING CLASS of service and DISA calls.

NOTE : Users must enter unique passcodes for using the STATION LOCK, DISA, and

WALKING CLASS of service. The default passcode does not apply.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 01

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [HOLD] to reset the selected station's

passcode to default data '1234'

If you forget passcode, use this MMC

4. Press [TRANSFER] to save and exit

DEFAULT DATA

1234

RELATED MMC

MMC 00 STATION LOCK

MMC 46 ASSIGN DISA LINE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 10 SET ANSWER MODE

This MMC is used to change the answer mode of any station to one of the following

options:

1 RING The keyset will ring. Calls are answered by pressing [SPEAKER],

or by lifting the handset.

2 AUTO ANSWER After a short attention tone, the key set will automatically answer

calls via speakerphone. When a C.O. line is transferred to a

keyset in Auto Answer Mode, the keyset will ring until pressing

[SPEAKER], or lifting the handset.

3 VOICE ANNOUNCE The keyset will not ring. After a short attention tone, caller can

make an announcement but [SPEAKER] button or handset must

be used to respond to the caller.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 10

2. Using [VOLUME (-) or (+)], select a station (e. g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to make selection

OR

Using KEYPAD, dial

1 for RING

2 for AUTO ANSWER

or 3 for VOICE ANNOUNCE (e.g. 2)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

RING

RELATED MMC

NONE

4Programming 1999.9.15 12:42 PM 페이지13

4Programming 1999.9.15 12:42 PM 페이지14

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 11 CALL FORWARD

This MMC is used to program the call forwarding destination for each station and to set

the time for FORWARD NO ANSWER.

Each station can forward calls under the following condition.

FORWARD ALL All calls are forwarded to destination station

FORWARD BUSY If the station is busy, calls are forwarded to destination

station.

FORWARD NO ANSWER If the station doesn't answer within the 'no answer' time,

calls are forwarded to destination.

NO ANSWER TIME Used to set 'no answer' time. This time is also used for

External Call Forward.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 11

2. Using [VOLUME (-) or (+)], select station (e. g. 202)

3. Press [REDIAL] or [FLASH] to select the forwarding

method described above

(e.g. FORWARD NO ANSWER)

4. Enter the destination station To clear the data,

press [HOLD]

If your selection is NO ANSWER TIME,

enter a 3 digit time in seconds

5. Press [TRANSFER] to save and exit

DEFAULT DATA

FORWARD TYPE : NONE

NO ANSWER TIME : 015 SEC

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 12 STATION ON/OFF

This MMC allows the keyset user to set the following features:

AUTO HOLD Places an existing C.O. call on hold if another trunk key (C.O.

button) is pressed during that call.

AUTO TIMER Automatically starts stopwatch timer during a C.O. call.

HEADSET USE When ON, this feature disables the hook switch, allowing a

headset user to answer calls by pressing [SPEAKER]

HOT KEYPAD When ON, this feature allows the user to dial directory numbers

without having to first lift the handset or press the [SPEAKER] button.

KEY TONE When ON, this feature allows the user to hear a slight tone when

pressing keypad numbers on their set.

RING PREFERENCE When OFF, requires the user to press the fast flashing button to

answer a ringing call after lifting the handset.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 12

2. Using [VOLUME (-) or (+)], select a station (e. g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [REDIAL] or [FLASH] to select the keyset features

described above (e.g. HEADSET USE)

4. Press [MUTE] or [MESSAGE] to make a selection

OR

Using KEYPAD, dial

0 for OFF

or 1 for ON (e.g. 1)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

AUTO HOLD : OFF

AUTO TIMER : ON

HEADSET : OFF

HOT KEYPAD : ON

KEY TONE : ON

RING PREFERENCE : ON

RELATED MMC

NONE

4Programming 1999.9.15 12:42 PM 페이지15

4Programming 1999.9.15 12:42 PM 페이지16

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 13 SET RING FREQUENCY

This MMC is used to select the ring frequency at each keyset. There are four types of ring

frequency available at each keyset. A sample of the selection can be heard when a dial

key pad is pressed.

PPROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 13

Display shows current ring frequency

2. Using [REDIAL] or [FLASH], select the station you

want (e.g. 202)

To select all stations, press [REDIAL] first

3. Press [MUTE] or [MESSAGE] to make selection.

A sample of selected frequency will be heard

OR

Using keypad, dial

1 for FREQUENCY 1

2 for FREQUENCY 2

3 for FREQUENCY 3

4 for FREQUENCY 4 (e.g. 2)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

FREQUENCY 1

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 14 STATION NAMES

This MMC is used to enter a name of up to twelve (12) characters to identify an individual

station.

Names are entered via the keypad. Each press of a key will select a character.

Pressing a different key will advance the cursor to the next position.

For example if the station name is "SAM SMITH", press the number "7" four times to get

the letter "S". The characters programmed by each dial pad are listed below:

Dial 1 2 3 4 5 6 7 8 9 0 #

C o u n t

1 Q A D G J M P T W : ?

2 Z B E H K N R U X . & [

3

C F I L O S V Y ! $ ]

4 1 2 3 4 5 6 7 8 9 0 #

NOTE : When the character you want appears on the same dial pad key as the previous

character, press [FLASH] to move the cursor to right.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 14

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Referring to the above list, the enter station name.

Use [FLASH] to advance cursor to the right

(up to 12 digits)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

Model name

RELATED MMC

NONE

4Programming 1999.9.15 12:42 PM 페이지17

4Programming 1999.9.15 12:42 PM 페이지18

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 15 DATA DISPLAY

This MMC is used to change date display mode of each stations. Following date display

mode are available.

NOTE: AS-30S and SKP-816 model keysets display Western format only.

1 24 WESTERN WED 21 JUN 17:37

2 12 WESTERN WED 21 JUN 05:37

3 24 EASTERN 06/21 WED 17:37

4 12 EASTERN 06/21 WED 05:37

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 15

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to make selection

OR

Using the KEYPAD, dial

1 for 24 WESTERN

2 for 12 WESTERN

3 for 24 EASTERN

or 4 for 12 EASTERN (e.g. 3)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

12 WESTERN

RELATED MMC

MMC 55 CURRENT DATE AND TIME

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 16 KEY EXTENDER

This MMC is used to view the programmable keys assigned to a keyset station.

It also allows the system administrator to assign key extenders to some keys to make a

feature key more specific. The feature keys accept extenders are:

FEATURE KEY EXTENDER

FWE External Call Forward(00~99)

SPEED Dial (00~99)

VAC Vacant messages (01~20)

PAG Page (0~5,)

DOR Door & Door Lock control (1~4)

EXC Boss and Secretary (1~2)

DPC Direct Pickup (station / trunk-line number)

GPC Group Pickup (0~9)

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 16

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

3. Press [REDIAL] or [FLASH] to select a feature key

button (e.g. 22)

OR

Press the button you want to extend if it is already

programmed.

4. Dial the extender according to the above table.

A previous extender will be overwritten

To clear the extended key, press [HOLD]

5. Press [TRANSFER] to save and exit

DEFAULT DATA

Key extender is set to STATION KEY PROGRAMMING (MMC 72) data.

RELATED MMC

MMC 71 SYSTEM KEY PROGRAMMING

MMC 72 STATION KEY PROGRAMMING

4Programming 1999.9.15 12:42 PM 페이지19

4Programming 1999.9.15 12:42 PM 페이지20

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 17 STATION SPEED-DIAL

This MMC is used to program the personal dial memory assigned to a station.

Each station may have up to 20 memory locations, numbered 00 to 19. Each dial number

consists of a trunk or trunk group access code followed by a separator ( : ) and up to 30

digits to be dialed. If you dial a valid trunk or trunk group access number, it will

automatically insert the separator.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 17

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

3. Press [REDIAL] or [FLASH] to select the entry.

OR

Dial the entry number (e.g.17)

If the data exceeds 13 digits, press [SPEED] to verify

the undisplayed data.

Display entry moves left 1 digit at a time

4. Enter station Number, Telephone number, or trunk

access code (e.g. 9), followed by the number to be

dialed (e.g. 4558971)

OR

Press [HOLD] to clear an entry

To make a digit invisible, press [MUTE] + digit + [MUTE].

(e.g. 9 + 455 [MUTE] 8 [MUTE] 971)

The digit will display as ' '

5. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE.

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 20 OPEN PROGRAMMING

This MMC is used to open or close Customer or Technician level programming.

If programming is not opened and an attempt is made to access a system MMC, the error

message [NOT PERMIT] will be displayed. A four-digit Customer passcode is required to

access Customer level programming allocated in MMC 90 (Customer MMC Number). Or

a four-digit Technician level passcode is required to open all the MMCs.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 20

2. Enter passcode

Default passcodes:

1234 for customer level programming

4321 for technician level programming

3. Press [MUTE] or [MESSAGE] to select DISABLE or

ENABLE

OR

Dial 0 to select DISABLE

or 1 for ENABLE

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DISABLE

RELATED MMC

CUSTOMER PROGRAMMING: Refer to MMC 90

TECHNICIAN LEVEL PROGRAMMING : ALL MMCs

4Programming 1999.9.15 12:42 PM 페이지21

4Programming 1999.9.15 12:42 PM 페이지22

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 21 CHANGE PASSCODE

Use this MMC to change the passcode allowing access to MMC 20 'Open Programming'.

NOTE: The passcode is four digits long. A digit may be 0 to 9.

The current (old) passcode is required for this MMC.

NOTE: Press [HOLD] to reset passcode to default value '1234'.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 21

2. Enter new passcode via KEYPAD(maximum four digits)

To change customer passcode, first enable the customer

program To change technician passcode, you first

enable your technician program

3. Display shows

Enter new passcode via KEYPAD

4. If reentered passcode is valid, display will show

"SUCCESS"

OR

If invalid, display will show "ERROR"

5. Press [TRANSFER] to save and exit

DEFAULT DATA

Customer passcode : 1234

Technician passcode : 4321

RELATED MMC

MMC 20 OPEN PROGRAMMING

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 22 CUSTOMER ON/OFF

This MMC is used to allow the system administrator to set any of the following keyset

features:

BGM When ON, allows the user to hear background music.

DND When ON, allows the user to set the Do Not Disturb feature.

DOOR When ON, allows the user to open the door

HUNT When ON, an intercom call will be forwarded to the next station of

station group to which the station belongs.

MIKE When ON, the station can activate the speakerphone.

PAGE USE When ON, the station can page.

PAGE RECEIVE When ON, the station will receive the paging announcements.

SMDR When OFF, information related to the station will not print on the

SMDR report.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 22

2. Using [VOLUME (-) or (+)], select a station

To select all stations, press [VOLUME (-)] first

3. Press [REDIAL] or [FLASH] to select keyset features

listed above

4. Press [MUTE] or [MESSAGE] to select data

OR

Using KEYPAD, dial

0 for OFF

or 1 for ON

5. Press [TRANSFER] to save and exit

DEFAULT DATA

BGM : ON

DND : ON

DOOR : ON

HUNT : OFF

MIKE : ON

PAGE USE : ON

PAGE RECEIVE : ON

SMDR : ON

RELATED MMC

HUNT : MMC 35 ASSIGN STATION GROUP

PAGE USE, PAGE RECEIVE : MMC 23 PAGE ZONE

SMDR : MMC 81 SMDR OPTION

4Programming 1999.9.15 12:42 PM 페이지23

4Programming 1999.9.15 12:42 PM 페이지24

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 23 PAGE ZONE

This MMC is used to assign a keyset to one (or none) of the four internal paging zones.

NOTE: Number 5 is external paging and ' ' assigns to all internal and external paging

zones.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 23

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to select

OR

Using KEYPAD, dial

0 for NO ZONE

1 for ZONE 1

2 for ZONE 2

3 for ZONE 3

or 4 for ZONE 4 (e.g. ZONE 1)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NO ZONE

RELATED MMC

MMC 22 CUSTOMER ON/OFF

PAGE USE

PAGE RECEIVE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 24 ASSIGN BARGE-IN

This MMC is used to set the type of barge-in permitted at a particular station.

After the barge-in type is set, the barge-in class can be set. The barge-in class allows or

disallows the user to barge-in on another station.

OPTION BARGE-IN TYPE DESCRIPTION

0 NO BARGE-IN Barge-in feature is unavailable regardless of a

station's barge-in status.

1 WITH TONE Barge-in will produce an intrusion tone and

display at the barged-in on station.

2 WITHOUT TONE Barge-in is allowed. There is no barge-in tone

and no display at the barged-in station, and the

barge-in station will be muted.

OPTION BARGE-IN CLASS DESCRIPTION

00 NN You cannot barge-in. / Nobody can barge-in on you.

01 NY You cannot barge-in. / Others can barge-in on you.

10 YN You can barge-in. / Nobody can barge-in on you.

11 YY You can barge-in. / Others can barge-in on you.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 24

2. Pressing [MUTE] or [MESSAGE] to select barge-in type

OR

Using KEYPAD, dial

0 for NO BARGE IN

1 for WITH TONE

or 2 for WITHOUT TONE

3. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

4. Using KEYPAD, dial

00 for NN

01 for NY

10 for YN

or 11 for YY

You can select barge-in closs (NN, NY, YN, YY)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

BARGE-IN TYPE : NO BARGE IN

BARGE-IN CLASS : NN

RELATED MMC

NONE

4Programming 1999.9.15 12:42 PM 페이지25

4Programming 1999.9.15 12:42 PM 페이지26

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 25 HOT/WARM LINE

This MMC is used to assign a hot line/prime line destination to a station.

The destination may be any of the following:

Station Number

Station Group Number

Trunk Number

Trunk Group Number

Speed-Dial location (00 to 99)

The Warm Line Delay Time is also assigned by this MMC.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 25

2. Using KEYPAD, select the destination (e.g. 233)

3. Enter a single digit for the Warm Line Delay Time

(0 - 9 Sec)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DESTINATION : NONE

WARM LINE DELAY TIME : 0 SEC

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 26 ALARM REMINDER

This MMC allows the system administrator or technician to set or change the alarm

clock/appointment reminder feature for any station. Three alarms may be set for each

station, and each alarm may be defined as a "DAY" alarm or as a "DAILY" alarm. The

DAY alarm is automatically canceled after it rings, while the DAILY alarm rings every day

at the same time.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 26

2. Use [VOLUME (-) or (+)], select a station (e.g. 202)

3. Press [REDIAL] or [FLASH] to select an alarm

number (1~3).

4. Dial the alarm time. The time is entered in 24 hour

format (0000 is 12:00 midnight)

To clear alarm data, press [HOLD]

5. Press [MUTE] or [MESSAGE] to select an alarm mode

6. Press [TRANSFER] to save and exit

DEFAULT DATA

ALARM MODE : DAY MODE

ALARM1 : HHMM DAY

ALARM2 : HHMM DAY

ALARM3 : HHMM DAY

RELATED MMC

MMC 55 CURRENT DATE AND TIME

4Programming 1999.9.15 12:42 PM 페이지27

4Programming 1999.9.15 12:42 PM 페이지28

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 27 VACANT MESSAGE

The system provides up to 20 vacant messages that can be selected by any display

keyset user. Messages 01 through 10 are pre-programmed, as shown below. Messages

11 through 20 may be customized via this MMC. The selected message will appeared in

the display of any calling station.

NO. MESSAGE

01 IN A MEETING

02 OUT ON A CALL

03 OUT TO LUNCH

04 LEAVE A MESSAGE

05 PAGE ME

06 OUT OF TOWN

07 IN TOMORROW

08 RETURN AFTERNOON

09 ON VACATION

10 GONE HOME

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 27

2. Use [VOLUME (-) or (+)] to select the desired message

number (11-20)

3. Enter the message text

Refer to MMC 14

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

MMC 14 STATION NAMES

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 28 CALL DISC

Used to assign the incoming and outgoing call disconnection per station.

There are four different option.

0 No Disconnection

1 Out Only

2 In Only

3 Both

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 28

2. Using [VOLUME (-) or (+)], select the station you want

(e.g. 202)

If you want to select all station, press [VOLUME (-)] first.

3. Press [MUTE] or [MASSAGE] in several times,

you can make selection

OR

Using KEYPAD, dial

0 for No Disconnection

1 for Out Only

2 for In Only

or 3 for both(e.g., 3)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NO DISC

RELATED MMC

MMC 50 SYSTEM TIMERS

TRK DISC

MMC 42 TRUNK ON/OFF

TRK DISC

4Programming 1999.9.15 12:42 PM 페이지29

4Programming 1999.9.15 12:43 PM 페이지30

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 30 STATION TOLL CLASS

This MMC is used to assign any of the 6 different day and/or night class of service to each

station, as per the table below:

DIAL DIGIT TOLL CLASS DESCRIPTIONS

1 A No restriction

2 B Follow allow/deny table for each class

3 C Follow allow/deny table for each class

4 D Follow allow/deny table for each class

5 E Follow allow/deny table for each class

6 F Intercom call only

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 30

2. Using [VOLUME (-) or (+)], select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Dial 1~6 (e.g. 2 3) (two digits, the first for Day and the

second for Night class), to select A~F class as per table

above. Display shows A~F class

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DAY CLASS : A

NIGHT CLASS : A

RELATED MMC

MMC 60 TOLL DENY TABLE/APPLY

MMC 61 TOLL ALLOW TABLE/APPLY

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 31 EXT/TRK USE

This MMC is used to allow trunks the ability to answer incoming calls, to dial out, or to do

both, on a per-station basis. Those abilities are displayed as Y or N for each action

(e.g. NY: disallow dialing out and allow answering incoming calls).

DIAL DIGIT TRK USE DESCRIPTION

00 NN You cannot either dial and answer

01 NY You cannot dial but can answer

10 YN You can dial but cannot answer

11 YY You can both dial and answer

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 31

2. Using [VOLUME (-) or (+)], Select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Select trunk number by pressing [REDIAL] or [FLASH]

repeatedly

To select all trunks, press [REDIAL] first

4. You can select NN, NY, YN or YY stations (e.g., NY)

Using KEYPAD,

0 for deny the action

1 for allow the action

(Two digits must be dialed. First digit for dialing out,

and second for answering incoming calls.)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

ALL TRUNK : YY

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지31

4Programming 1999.9.15 12:43 PM 페이지32

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 32 INTERCOM USE

This MMC is used to allow/disallow station intercom calls.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 32

2. Use [VOLUME (-) or (+)], to select a station (e.g. 202)

To select all stations, press [VOLUME (-)] first

3. Press [REDIAL] or [FLASH] to select call station

(e.g. ALL)

To select all stations, press [REDIAL] first

4. Press [MUTE] or [MESSAGE] to select the

allow/disallow option (e.g. disallow all intercom calls)

OR

Using KEYPAD, dial

0(N) for disallow intercom call

1(Y) for allow intercom call

If you set N, intercom calls are not possible,

calling the operator is possible

5. Press [TRANSFER] to save and exit.

DEFAULT DATA

CALL ALL : Y

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 33 ASSIGN DOOR RING

This MMC is used to designate which devices (station or station group) will ring when a

door box button is pressed.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 33

Display shows designated stations or station

groups for DOOR1 (day and night)

2. Press [VOLUME (-) or (+)] to select DOOR 1 or

DOOR 2

3. Enter new DAY/NIGHT selection via dial keypad

(e.g. 501 for day, and 201 for night)

4. Press [TRANSFER] to save and exit.

DEFAULT DATA

DOOR1: DAY: 500 NIGHT: 500

DOOR2: DAY: 500 NIGHT: 500

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지33

4Programming 1999.9.15 12:43 PM 페이지34

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 34 ASSIGN PICKUP GROUP

This MMC is used to allow the assignment of stations to call pickup groups.

There may be a maximum 10 pickup groups (0~9). An unlimited number of members can

belong to each group. Stations can be in only one pickup group at any given time.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 34

Display shows the first member of pickup group 0

2. Using [VOLUME (-) or (+)], select a pickup group

number (e.g. GPC1)

3. Press [REDIAL] or [FLASH] to scroll through the

members of the selected pickup group

4. Dial station number

If dialed number is the member of another pickup

group, the station number will removed from the

previous group automatically.

Dialed number overwrites the previous number.

5. Press [TRANSFER] to save and exit

DEFAULT DATA

[GPC0] : All stations

[GPC1][GPC9] : NONE

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 35 ASSIGN STATION GROUP

This MMC is used to assign members of a station group. There are several options that

can be selected for ringing, overflow, group transfer and overflow destination, and group

type. There may be a maximum twenty (20) groups.

OPTIONS DISPLAY RANGE

Ring mode RING

Overflow time OVER 000 250 sec

Group transfer time TRSF 000 250 sec

Overflow port NEXT

Group types TYPE

RING MODES DESCRIPTION

1 SEQUENTIAL The first idle station listed in the group will ring. If the first is busy,

the next idle station will ring.

2 DISTRIBUTE The first call will ring the first station listed in the group.

The next call will ring the next station listed in the group.

3 CONDITION All the stations but non-busy stations listed in the group will ring.

4 UNCONDITION All the stations listed in the group will ring. Busy stations will

receive off-hook ring.

GROUP TYPES

1 NORMAL GROUP

2 VMAA GROUP

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 35

Display shows ring mode of Operator group 500.

2. Using [VOLUME (-) or (+)], select a station group

number (500519).

3. Press [REDIAL] or [FLASH] to select options

(RING, OVER, TRSF, NEXT, TYPE, MEMBER)

4a. Press [MUTE] or [MESSAGE] to select ring mode

OR

Dial

1 for SEQUENTIAL

2 for DISTRIBUTE

3 for CONDITION

or 4 for UNCONDITION

4b. To change the OVERFLOW TIME, enter 3 digits of

OVERFLOW TIME

4c. To change the GROUP TRANSFER TIME, dial 3 digits

of GROUP TRANSFER TIME

4Programming 1999.9.15 12:43 PM 페이지35

4Programming 1999.9.15 12:43 PM 페이지36

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 35

4d. To assign the overflow port, enter the station or station

group number.

4e. Press [MUTE] or [MESSAGE] to select the station

group type

OR

Using KEYPAD,

1 for NORMAL GROUP

2 for VMAA GROUP

4f. To assign amember to the station group, enter the

station number.

If dialed number is the member of another station group,

the station number will removed from the previous group

automatically.

Dialed number overwrites the previous number.

5. Press [TRANSFER] to save and exit

DEFAULT DATA

RING : DIST

OVERFLOW : 030 SEC

TRANSFER TIME : 045 SEC

TYPE : NORMAL GROUP

MEMBER : 201

GROUP : 500

OTHER GROUP : NONE

RELATED MMC

MMC 22 CUSTOMER ON/OFF

HUNT

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 36 ASSIGN BOSS/SECRETARY

This MMC is used to assign BOSS keysets to SECRETARY keysets. One SECRETARY

station may include two (2) BOSS stations.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 36

2. Using [VOLUME (-) or (+)], select the SECRETARY

station (e.g. 202)

Display shows the BOSS stations

3. Enter the BOSS stations

(e.g. BOSS1: 220, BOSS2: 230)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

BOSS1: NONE BOSS2: NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지37

4Programming 1999.9.15 12:43 PM 페이지38

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 37 ASSIGN ADD-ON MODULE

This MMC is used to assign an add-on module (AOM) to a station.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 37

Display shows the first AOM port

If there is no AOM port, display shows:

2. Press [VOLUME (-) or (+)], to select the AOM port

To clear any previous entry, press [HOLD]

3. Enter master station number

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 38 SLT DIALING TYPE

This MMC is used to define the dial type of phone connected to each SLT port.

Keysets are not affected by this MMC.

There are two dialing types:

DIALING TYPES

1 DTMF Dual Tone Multi-Frequency (Touch Tone)

2 PULSE Dial Pulse (rotary)

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 38

Display shows the SLT port (e.g. 217)

If there is no SLT port, display shows

2. Using [VOLUME (-) or (+)], select the SLT port number

To select all stations, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to select the SLT type.

OR

Using KEYPAD, dial

1 for DTMF

or 2 for PULSE

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DTMF

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지39

4Programming 1999.9.15 12:43 PM 페이지40

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 39 DATA LINE

Used to assign SLT ports to be used for data transmission.

VOICE - The station will be used for voice communication. All intrusion and

warning tones will be heard during conversation.

DATA - The station will be used for data communication. No intrusion or warning

tones will occur during data transmission.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 39

2. Display shows.(e.g. 209 is SLT port)

3. Using [VOLUME (-) or (+)], select the SLT port number.

To select all SLT ports, press [VOLUME (-)] first

4. Press [MUTE] or [MESSAGE] to select VOICE or DATA

The port is set to DATA line.

OR

Dial

1 for VOICE

or 2 for DATA

5. Press [TRANSFER] to save and exit

DEFAULT DATA

VOICE line

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 40 C.O./PBX LINE

This MMC is used to select the mode of the C.O. line. If the PBX mode is chosen, the

PBX access code can be recognized allowing more complete toll restrictions.

This mode is assigned on a per-trunk basis.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 40

2. Using [VOLUME (+) or (-)], select the trunk number

(e.g. 702)

To select all trunk lines, press [VOLUME (-)] first

3. Pressing [MUTE] or [MESSAGE], you can set the

trunk to C.O. or PBX line

OR

Using KEYPAD, dial

1 for C.O line

or 2 for PBX line

4. Press [TRANSFER] to save and exit

DEFAULT DATA

C.O. LINE

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지41

4Programming 1999.9.15 12:43 PM 페이지42

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 41 TRUNK DIALING TYPE

This MMC is used to set the dial type of each C.O. line.

There are two options:

DTMF : Dual Tone Multi Frequency (Touch Tone)

PULSE : Pulse dial (rotary).

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 41

2. Using [VOLUME (-) or (+)], select the trunk number

To select all trunk lines, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to select the trunk dial type

OR

Using KEYPAD, dial

1 for DTMF

or 2 for PULSE

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DTMF

RELATED MMC

MMC 53 TRUNK WIDE TIMER

MMC 54 MAKE/BREAK RATIO

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 42 TRUNK ON/OFF

This MMC is used to assign trunk options on a per-trunk basis.

OPTION DESCRIPTION

1A2 EMULATION Trunk override call

TRUNK FORWARD Allow trunk to be forwarded

RING OVER PAGE Allow ring over external page

TOLL CHECK FREE C.O. lines to follow or bypass toll restriction

VOICE MSG Voice announcement on DISA line

TRK DISC Allows trunk to be discnnected

PROCEDURE LCD DISPALY

1. Press [TRANSFER] and dial 42

2. Using [VOLUME (-) or (+)], select trunk number

To select all trunks, press [VOLUME(-)] first

3. Using [REDIAL] or [FLASH], select an option

described above

4. Press [MUTE] or [MESSAGE] to select ON or OFF.

OR

Using the KEYPAD, dial

0 for OFF

or 1 for ON

5. Press [TRANSFER] to save and exit

DEFAULT DATA

1A2 EMULATION : OFF TRUNK FORWARD : OFF

RING OVER PAGE : OFF TOLL CHECK FREE : OFF

VOICE MSG : OFF TRK DISC : OFF

RELATED MMC

TRUNK FORWARD : MMC 11 CALL FORWARD

VOICE MSG : MMC 46 ASSIGN DISA LINE

TRK DISC : MMC 50 SYSTEM TIMER(TRK DISC)

MMC 28 CALL DISC

4Programming 1999.9.15 12:43 PM 페이지43

4Programming 1999.9.15 12:43 PM 페이지44

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 43 ASSIGN TRUNK RING

A trunk may have a maximum 16 members(station or station group) assigned to ring.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 43

2. Using [VOLUME (-) or (+)], select the trunk you want

(e.g., 703)

3. Press [REDIAL] or [FLASH], select the options

(RING MODES, DAY MEMBERS or NIGHT

MEMBERS) (e.g., RING MODES)

4a. Press [MUTE] or [MESSAGE], to select ring mode

OR

Dial 1 for SEQUENTIAL

2 for DISTRIBUTE

3 for CONDITION

or 4 for UNCONDITION

(e.g., UNCONDITION)

4b. Dial the station or station group number that will be

ringing to(e.g., 500 for the first memver of Day mode)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

All trunks Day1 :500

Night1 :500

RELATED MMC

MMC 35 ASSIGN STATION GROUP

MMC 56 ASSIGN AUTO NIGHT TIME

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 44 TRUNK NAMES

This MMC is used to assign a name of up to twelve (12) characters to identify a particular

trunk.

Names are written using the keypad. Each press of a key will select a character.

Pressing a different key moves the cursor to the next position.

Dial 1 2 3 4 5 6 7 8 9 0 #

C o u n t

1 Q A D G J M P T W : ?

2 Z B E H K N R U X . & [

3

C F I L O S V Y ! $ ]

4 1 2 3 4 5 6 7 8 9 0 #

NOTE : When the next character appears on the same dial pad key as the current

character, press [FLASH] to move the cursor to the right, or to enter a space.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 44

2. Press [VOLUME (-) or (+)] to select the trunk to name

3. Enter the trunk name(refer to above chart)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지45

4Programming 1999.9.15 12:43 PM 페이지46

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 45 TRUNK GROUP

This MMC is used to set the free trunk selection type to a specific trunk, trunk group, or to

several trunk groups.

There are eleven (11) trunk groups: 9 and 80 through 89, and three types of selecting a

free trunk line in the group.

MODE DESCRIPTION

DISTRIBUTE Searches the trunk group in circular order. Each time the group is

accessed, the next available trunk in the group is selected.

High to Low Searches the trunk group last to first trunk in the group. If a trunk

is busy, the previous available trunk in the group is selected.

Low to High Searches the trunk group. If the first trunk in the group is busy,

the next iavailable trunk in the group is selected.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 45

Display shows the first free trunk selection type

2. Using [MUTE] or [MESSAGE], select the free trunk

selection mode

OR

Using KEYPAD, dial

1 for DISTRIBUTE

2 for High to Low

or 3 for Low to High.

3. Using [VOLUME (-) or (+)], select the trunk group

4. Press [REDIAL] or [FLASH] to scroll through the group

If dialed number is the member of another trunk group,

the trunk number will removed from the previous group

automatically. Dialed number overwrites the previous number.

5. Enter a valid trunk number

6. Press [TRANSFER] to save and exit

DEFAULT DATA

GROUP 9 : All trunk lines

GROUP 80~89 : NONE

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 46 ASSIGN DISA LINE

This MMC is used to allow the system the ability to have Direct Inward System Access

(DISA). There are four 4 DISA. If a trunk is set to DISA, the voice announcement feature

may be used when the VOICE MSG option is enabled in MMC 42 TRUNK ON/OFF.

OPTIONS DESCRIPTION

0 NO DISA LINE No DISA service

1 DISA IN NIGHT MODE In night mode, DISA is available

2 DISA IN DAY MODE In day mode, DISA is available

3 DISA BOTH NIGHT AND DAY In day and night mode, DISA is available

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 46

Display shows

2. Using [VOLUME (-) or (+)], select the trunk you want

(e.g. 702)

To select all trunks, press [VOLUME (-)] first

3. Press [MUTE] or [MESSAGE] to select

OR

Using KEYPAD, dial

0 for NO DISA LINE

1 for DISA IN NIGHT MODE

2 for DISA IN DAY MODE

3 for DISA BOTH NIGHT AND DAY

(e.g. 1)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

All trunks : NO DISA

RELATED MMC

MMC 42 TRUNK ON/OFF VOICE MSG

4Programming 1999.9.15 12:43 PM 페이지47

4Programming 1999.9.15 12:43 PM 페이지48

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 50 SYSTEM TIMERS

This MMC is used to adjust individual timers as necessary. All available timers are

described in the TABLE OF TIMERS AND VALUES.

NOTE: Seconds are shown as 'SEC', milliseconds as 'MS', and minutes as 'MIN'.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 50

2. Press [VOLUME (-) or (+)] to select a timer

(e.g. ALM R DUR)

3. Enter new value using KEYPAD

4. Press [TRANSFER] to save and exit

DEFAULT DATA

See TABLE OF TIMERS AND VALUES

RELATED MMC

NONE

TABLE OF TIMERS AND VALUES

DISPLAY DESCRIPTION DEFAULT RANGE

ALM R INT controls the time length between ring attempts 025SEC 250SEC

(Alarm ring at a station when alarm reminder is set.

interval)

ALM R DUR controls the length of ring cycle duration when 010SEC 1~250SEC

(Alarm ring alarm reminder is set at a station.

duration)

ARDL INT controls the time between attempts after Auto 045SEC 1~250SEC

(Auto Redial Redial is set 'ON' at a station.

interval)

ARDL RELS controls the duration of a Ring No Answer 045SEC 1~250SEC

(Auto Redial condition on an auto-redial number dialed

release time) before auto redial is canceled.

CBACK NOA controls the time before the callback is canceled 030SEC 1~250SEC

(Callback no when a callback detects Ring No Answer

answer time)

CO CO DIS monitors the duration of an unsupervised 010MIN 1~250MIN

(CO to CO conference, external call forward, or DISA call.

disconnect upon expiring, both trunks are disconnected.

time)

DISA F DG controls how long the system will wait for 025SEC 1~250SEC

dialing to begin the DISA incoming call.

DISA I DG controls the grace period between dialing valid 025SEC 1~250SEC

digits before dropping the call to DISA user.

DISA RING controls no answer time for DISA internal calling. 030SEC 1~250SEC

DOOR RELS controls the duration of time before the door 1500MS 100~

(Door release lock relay deactivates. 2500MS

time)

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 50

DISPLAY DESCRIPTION D E F A U L T RANGE

DOR R OFF controls the duration of ringing at the door 030SEC 1~250SEC

(Door Ring ring destination before canceling

OFF time)

FIRST DGT controls how long the system will wait for 025SEC 1~250SEC

(First Digit dialing to begin before dropping the dial tone

wait time) and initiating an error tone.

HOOK OFF controls the time before dial tone is sent to a 0200MS 100~

(Hook OFF single-line station. 2500MS

time)

INTER DGT controls the grace period between dialing 025SEC 1~250SEC

(Inter Digit valid digits before dropping the call and

duration) returning the user back to an error tone.

MMC OUT controls the grace period between programming 030SEC 1 0 ~ 2 5 0 S E C

(MMC actions while in a programming session, before

session time) returning system to secure programming status.

OFF R INT controls the duration of time between ring 015SEC 1~250SEC

(Off hook bursts to a user who has a camped-on call.

Ring Interval)

PAGE MAX controls the allowed duration of a page 020SEC 1~250SEC

(Page duration) announcement.

RCAL DISC this is the time an attendant recall will 002MIN 1~250MIN

(Recall ring before being disconnected.

Disconnect

time)

RCAL RING this is the length of time a transfer recall 015SEC 0~250SEC

(Recall Ring will ring at a station before recalling the

length) operator

RCAL WAIT after a transferred call is recalling at the transferring 015SEC 0~250SEC

(Recall station and the station is busy, this timer will expire

Waiting time) and transfer the call to the operator.

This only applies to trunk calls.

RCAL HOLD determines the time calls can be left on hold 045SEC 0~250SEC

(Recall Hold before recalling back to the holding station.

time)

RCAL TRSF determines the time transferred calls ring 045SEC 0~250SEC

(Recall before recalling.

Transfer time)

SLT F MIN monitors the duration of a hookswitch flash to ensure that 0350MS 100~

(minimum SLT the flash is valid and not a line transient or accidental 2500MS

Flash time) hookswitch bounce. It is the minimum time of single-line station.

SLT F MAX maximum time of hookswitch flash of a 0800MS 100~

(maximum SLT single-line station. 2500MS

flash time)

SMDR PULS this grace period timer starts SMDR recording 030SEC 1~250SEC

(SMDR start for pulse (rotary) dialing and controls the

time for rotary LCD duration timer on the keysets.

dialing)

SMDR DTMF this grace period timers starts SMDR recording 015SEC 1~250SEC

(SMDR start for DTMF (Touch Tone) dialing and controls

time for touchtone the LCD duration timer on the keysets.

dialing)

TRK DISC controls the duration of an outside call 030MIN 1~250MIN

4Programming 1999.9.15 12:43 PM 페이지49

4Programming 1999.9.15 12:43 PM 페이지50

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 51 TONE/RING CADENCE

This MMC is used to customize the tone cadence on a system-wide basis to any one of

the eight available selections.

Call Technical Support before changing any cadences, as some systems may require

default settings.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 51

Display shows

2. Press [VOLUME (-) or (+)] to select a tone

3. Press [MUTE] or [MESSAGE] to set dial tone to

continuous or interrupted tone

Interrupt tone default data is: 1000 0250 1000 0250 ms

4. Dial new interrupt value for interrupt time,

(ON/OFF/ON/OFF) in 50 ms steps.

Each field is 3 digits (UNIT: 10 ms)

(e.g. 100/030/100/030 = 1000 ms [100× 10]

'ON' and 300 ms [030× 10] 'OFF' time)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

TONE NAME DISPLAY DATA

DIAL TONE (DT) CONTINUOUS TONE

RING BACK TONE (RBT) 1000 2000 1000 2000 ms

BUSY TONE (BST) 0500 0500 0500 0500 ms

TRSF TONE (TT) 0200 0200 0200 0200 ms

ERROR TONE (ERT) 0500 0250 0500 0250 ms

CO LINE RING (COR) 1000 3000 1000 3000 ms

STATION RING (STR) 0400 0200 0400 3000 ms

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 52 SYSTEM WIDE COUNTER

This MMC is used to set the values of the system counters.

The counters and descriptions are listed below:

OPTIONS DESCRIPTION

ALM COUNTER This is the number of times (1 to 99) that an alarm

(ALARM REMINDER reminder will ring a station before canceling.

COUNTER)

ARDL COUNTER This is the number of times (1 to 99) the system will redial

(AUTO REDIAL COUNTER) an outside number after the auto redial feature has been

activated.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 52

Display shows:

2. Press [VOLUME (-) or (+)] to select a counter

3. Use keypad to enter new data as a two-digit number

(e.g. 5 = 05)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

ALM COUNTER : 3

ARDL COUNTER : 10

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지51

4Programming 1999.9.15 12:43 PM 페이지52

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 53 TRUNK WIDE TIMER

This MMC is used to changed trunk timer values. It is not advisable to change these

values, with exception of trunk flash time, without assistance from Technical Support.

The available options are and listed below:

DISPLAY DESCRIPTION RANGE

CLEARING The interval for reuse of trunk after disconnecting a call. 0~25sec

(clearing time)

CO SUPV C.O. checking 00~9000

(CO supervision time) msec

F DGT DLY After seizing a trunk line, system sends the first digit 1 0 0 ~ 2 5 0 0

(first digit delay time) after this time. ms

FLASH PBX The duration of a flash when connected to a C.O. 1 0 0 ~ 2 5 0 0

(PBX flash time) ms

MFS ON TM The duration of DTMF Sender 'ON' status when 1 0 0 ~ 2 5 0 0

(MF sender on time) sending DTMF signal. ms

MF OFF TM The interval of DTMF Sender 'OFF' when system 1 0 0 ~ 2 5 0 0

(MF sender off time) sends DTMF signal. ms

MPD DETCT The minimum duration of MPD signal when the 40~500

(MPD detect time) signal is incoming. msec

NEW CALL The duration of a flash sent to the central office to 100~9900

(New Call time) disconnect the line. ms

NO RING if an incoming call is detected and is disconnected without 1~25sec

(no ring time) call processing, the system and releases the C.O line.

PAUSE TM This is a dialing pause duration timer. A pause is an 1~25sec

(pause time) instruction for the system to wait.

RNG DETCT Must be set shorter than the 'ON' cycle of a C.O. ring to prevent 100~2500

(ring detect time) transient noise on the C.O. line from triggering a false ring. ms

NOTE : Seconds shown as 'sec', milliseconds as 'ms', and minutes as 'mi'.

PROCEDURE LCD DISPLAY

1. Press [TRSF/ALM] and dial 53

Display shows

2. Press [VOLUME (-) o r( + ) ] to select a timer (e.g. CO SUPV)

3. Dial new time data(e.g. 0500)

4. Press [TRSF/ALM] to save and exit

DEFAULT DATA

CLEARING : 00 SEC CO SUPV : 0000 MSEC

F DGT DLY : 1000 MSEC FLASH PBX : 0600 MSEC

MFS ON TM : 0100 MSEC MF OFF TM : 0100 MSEC

MPD DETCT : 0060 MSEC NEW CALL : 2000 MS

NO RING : 05 SEC PAUSE TM : 03 SEC

RNG DETCT : 0200 MSEC

RELATED MMC NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 54 MAKE/BREAK RATIO

This MMC is used to allow the ability to change the duration of the make/break time of

pulse (rotary) dial trunks.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 54

2. Enter the MAKE/BREAK ratio on the KEYPAD

(e.g. MAKE:40 BREAK:60)

3. Press [TRANSFER] to save and exit

DEFAULT DATA

MAKE : 33

BREAK : 66

RELATED MMC

MMC 41 TRUNK DIALING TYPE

MMC 55 CURRENT DATA AND TIME

This MMC is used to set the system date and time on the system-wide clock.

YY Year 00~99 (e.g. 1995 = 95)

MM Month 01~12

DD Date 01~31

W Day 0~6 (0:SUN 1:MON 2:TUE 3:WED

4:THU 5:FRI 6:SAT)

HH Hour 00~23

MM Minute 00~59

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 55

Display shows

2. Enter current date and time using above table

display = 1995. 7. 5. Wednesday, 11:35

3. Press [TRANSFER] to save and exit

DEFAULT DATA

SAT 01 JAN 12:00

RELATED MMC

MMC 15 DATE DISPLAY

4Programming 1999.9.15 12:43 PM 페이지53

4Programming 1999.9.15 12:43 PM 페이지54

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 56 ASSIGN AUTO NIGHT TIME

This MMC is used to automatically place the system in Night mode. A Night key is not

needed, as the system switches automatically, but it is helpful to have a dedicated button

so the status can be changed manually. 'D' in the display is the time the system will

switch from Night to Day service and 'N' is the time the system will switch from Day to

Night service. There are three types of automatic Night timetables (WEEK, SATURDAY,

SUNDAY), each composed of two time settings.

Table type Description

WEEK Monday through Friday

SATURDAY Saturday

SUNDAY Sunday

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 56

Display shows

2. Press [VOLUME (-) or (+)] to select a timetable

There are six tables available (WEEK1, WEEK2, SAT.1,

SAT.2, SUN.1, SUN.2)

To switch to Night mode twice a day, you must enter both

times in related tables. (e.g. WEEK1 and WEEK2; SAT.1

and SAT.2)

If it is not, the system will switch to the night mode once

a day.

3. Enter the Day mode start time, then the Night mode start time.

Eight digits must be entered. If there are less than eight

digits, data will not change.

3a. To switch twice a day, you must enter data in both

related tables (e.g. WEEK1 and WEEK2)

A N D

4. Press [TRANSFER] to save and exit

DEFAULT DATA

DAY : 0000

NIGHT : 0000

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 57 CALL COST

This MMC is used to program the unit cost of the metering pulse generated by the Central

Office. If the MPD card is installed, it will detect the metering pulse provided by Central

Exchange and determine the call cost by the number of metering pulses and unit cost

programmed via this MMC. The unit cost is a four (4)digit number, and is measured in the

minimum money denomination in the country of use.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 57

Display shows

2. Enter the 4-digit unit cost.

If you don't enter 4 digits, the existing data will not be

changed.

3. Press [TRANSFER] to save and exit

DEFAULT DATA

UNIT COST : 0000

(The range of the CALL COST is 0001 ~ 9999)

RELATED MMC

NONE

MMC 60 TOLL DENY TABLE/APPLY

This MMC enables you to define which leading digit(s) in a dialing plan are to be restricted and

which class(es) should be applied in this toll deny table. Each entry can define up to 11 digits.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 60

2. Press [MUTE] or [MESSAGE] select the search class

(search class = NEW, ALL, B,C,D,E)

3. Press [VOLUME (-) or (+)], to find the desired entry or

an empty entry

4. Enter the dial number to be restricted and press [ C A L L B A C K ]

to assign the toll restriction apply class And dial four(4) digits,

0 for NO 1 for YES

5. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

MMC 30 STATION TOLL CLASS

MMC 61 TOLL ALLOW TABLE/APPLY

MMC 65 ASSIGN WILD CHARACTER

4Programming 1999.9.15 12:43 PM 페이지55

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 61 TOLL ALLOW TABLE/APPLY

This MMC enables you to define which leading digit(s) in a dialing plan are to be allowed

and which class(es) should be applied in this allow table.

Each entry can define up to 11 digits.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 61

2. Press [MUTE] or [MESSAGE] select search class

3. Pressing [VOLUME (-) or (+)], you can find the desired

entry or empty entry

4. Enter the dial number to be allowed and press

[ C A L L B A C K ] to assign the toll class And dial four(4) digits,

0 for NO

1 for YES

5. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

MMC 30 STATION TOLL CLASS

MMC 60 TOLL DENY TABLE/APPLY

MMC 65 ASSIGN WILD CHARACTER

MMC 62 PBX ACCESS CODE

This MMC is used to identify PBX access codes for toll restriction purposes. When a PBX line is

accessed, the dial tone originates in the PBX and extention numbers on that switch can be dialed.

To get an outside line, an access code must be dialed. If this access code appears in this list, it is

ignored and the toll restrition plan examines the digits following the PBX access code which has

five entries numbered 1 through 5. There is a maximum of four digits for each entry.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 62

2. Press [VOLUME (-) or (+)] to select the entry

3. Enter new PBX access code(e.g. 9) (maximum 4 digits)

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지56

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 63 AUTHORIZATION TABLE

This MMC is used to list all allowable authorization codes. An authorization code must be four

digits long. There are 50 codes allowed in this table. Duplications or number conflicts are not

permitted. Each authorization code has an associated dialing class of service. When the code is

entered, the dialing class of service is changed to that of the authorization code.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 63

2. Enter two digits (01~50), or press [VOLUME (-) or (+)]

to select the entry

3. Enter four digit code and dialing class (e.g. 1207 and 1)

There are five dialing class

1 : A CLASS

2 : B CLASS

3 : C CLASS

4 : D CLASS

5 : E CLASS

4. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

MMC 46 ASSIGN DISA LINE

4Programming 1999.9.15 12:43 PM 페이지57

4Programming 1999.9.15 12:43 PM 페이지58

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 64 OVERRIDE TABLE

This MMC is used to enter up to five exceptions to toll restriction. These exceptions can

be accessed by any class in both Day and Night modes, and are useful to allow access to

emergency numbers. Caution should be used regarding the entries of this table because

they will not be blocked for outgoing calls.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 64

2. Press [VOLUME (-) or (+)] to select the urgent code

number that you want

3. Enter the number to allow(e.g. 911)

4. Press [TRANSFER] to store and exit

DEFAULT DATA

NONE

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 65 ASSIGN WILD CHARACTER

Provides flexibility to toll restriction when a specific numbering plan is desired. There are

only three entry tables, but more than one digit can be assigned per table if necessary.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 65

2. Press [VOLUME (-) or (+)] to select the wild character

(X,Y or Z)

3. Enter 0 in the desired digit position. Twelve (12) digits

must be entered. If there are less than twelve digits,

data will not be changed

4. Press [TRANSFER] to save and exit

DEFAULT DATA

1 2 3 4 5 6 7 8 9 0 #

X : 1 1 1 1 1 1 1 1 1 1 1 1

Y : 1 1 1 1 1 1 1 1 1 1 1 1

Z : 1 1 1 1 1 1 1 1 1 1 1 1

RELATED MMC

MMC 60 TOLL DENY TABLE/APPLY

MMC 61 TOLL ALLOW TABLE/APPLY

4Programming 1999.9.15 12:43 PM 페이지59

4Programming 1999.9.15 12:43 PM 페이지60

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 66 SYSTEM SPD-DIAL TOLL RESTRICTION

Enables you to define whether the system allows or denies long distance numbers in

system Speed-Dialing to override toll restriction.

BYPASS TOLL Any station can use system speed dial numbers without

restriction, regardless of class

FOLLOW TOLL The system checks all the system Speed-Dialings according

to the station class and deny/allow table.

PROCEDURE LCD DISPALY

1. Press [TRANSFER] and dial 66

2. Press [MUTE] or [MESSAGE] to select data

OR

Dial 1 for BYPASS TOLL

or 2 for FOLLOW TOLL

3. Press [TRANSFER] to save and exit

DEFAULT DATA

BYPASS TOLL RESTRICTION

RELATED MMC

MMC 30 STATION TOLL CLASS

MMC 60 TOLL DENY TABLE/APPLY

MMC 61 TOLL ALLOW TABLE/APPLY

MMC 67 ASSIGN SYSTEM SPEED DIAL

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 67 ASSIGN SYSTEM SPEED-DIAL

This MMC is used to store up to eighty (80) system Speed-Dial numbers. The system

Speed-Dial number is composed of 2 digits (20 to 99) and a maximum 30-digit telephone

number can be stored at each Speed-Dial number. Eighty (80) system Speed-Dial

numbers are available to every station and the toll restriction is determined by MMC 66. A

Speed-Dial number consists of an access code and the telephone number to be dialed.

The access code can be any trunk group, individual trunk, station group, or individual

station. Dialing a valid trunk, trunk group, station or station group access number

automatically inserts the separator character (:).

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 67

2. Using [VOLUME (-) or (+)], select the entry

OR

Dial the entry number (20~99)

3. Enter the speed dial number of up to 30 digits.

4. Enter trunk access code (e.g. 9) followed by the number

to be dialed (e.g. 1234567)

5. Press [VOLUME (-) or (+)] to enter another speed dial

number and return to step 3

6. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:43 PM 페이지61

4Programming 1999.9.15 12:44 PM 페이지62

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 70 DIAL NUMBERING PLAN

This MMC provides the access codes and dialing plan needed for operation of features

and programs. The system comes with a wide range of acceptable numbering plans set

as default, and the option to customize the dialing plan. There is also a confirm message

provided due to the chance of duplicating an access or feature code.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 70

2. By pressing [MUTE] or [MESSAGE], select the

desired numbering plan group (STATION, STATION

GRP, TRUNK, TRUNK GRP or FEATURE)

3. Search the desired numbering plan entry by pressing

[VOLUME (-) or (+)]

4. Enter digits via the dial keypad (Max 3digits)

5. Press [VOLUME (-) or (+)] to enter change and

continue to make changes

OR

Press [MUTE] or [MESSAGE] to enter change and

continue to selecting numbering plan groups in step 2

If confirm message appears indicating duplication of

access code, dial

0 for no change

1 for change

6. Press [TRANSFER] to save and exit

DEFAULT DATA

ACC : 47 : ACCOUNT CODE

ALM : 58 : ALARM

AMD : 68 : ANSWER MODE

ATH : 65 : AUTHORIZATION CODE

BRG : 40 : BARGE-IN

CBK : 44 : CALL BACK

CMP : 45 : CAMP-ON

CNF : 46 : CONFERENCE

COS : 59 : CLASS OF SERVICE

CPS : 54 : CHANGE PASSCODE

DND : 64 : DO NOT DISTURB

DOR : 13 : DOOR

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 70

DPC : 10 : DIRECT PICKUP

EXC : 12 : EXECUTIVE / SECRETARY

FAT : 14 : FORCED AUTO ANSWER

FLS : 49 : FLASH

FWA : 61 : CALL FORWARD ALL

FWB : 62 : CALL FORWARD BUSY

FWC : 60 : CALL FORWARD CANCEL

FWN : 63 : CALL FORWARD NO ANSWER

GPC : 66 : GROUP PICK UP

GPS : : SELF GROUP PICK UP

HED : 69 : HEADSET

HLD : 11 : HOLD

IOG : 53 : IN / OUT GROUP

LNR : 19 : LAST NUMBER REDIAL

MPG : 56 : MEET ME PAGE

MSA : 43 : MESSAGE ANSWER

MSC : 42 : MESSAGE CLEAR

MSL : 41 : MESSAGE LEFT

OPR : 0 : OPERATOR

PAG : 55 : PAGE

REC : 18 :DISA VOICE RECORDING

SDI : 15 : SPEED DIAL INSERTION

SGR : 500-519 : STATION GROUP

SNR : 17 : SAVED NUMBER REDIAL

SPD : 16 : SPEED

STN : 2XX : STATION NUMBER

TRK : 7XX : TRUNK NUMBER

TGR : 9, 80~89 : TRUNK GROUP

UPC : 67 : UNIVERSAL NIGHT ANSWER

VAC : 48 : VACANT MESSAGE

RELATED MMC

ALL PROGRAMS AND FEATURES

4Programming 1999.9.15 12:44 PM 페이지63

4Programming 1999.9.15 12:44 PM 페이지64

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 71 SYSTEM KEY PROGRAMMING

This MMC allows for the customizing of programmable keys system-wide.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 71

2. Using [VOLUME (-) or (+)], select the type of keyset

There are 7 keyset types: NX 24, NX 12, NX 6,

SKP 816, AS 30, AS 12S, NX AOM.

3. Press the desired key

OR

Press [ R E D I A L ]or [ F L A S H ] to select desired key. (e.g. 13)

4. Enter the key programming via keypad.

Trunk number, Trunk Group number, Station number,

Station Group number, or feature number can be

programmed into the keys.

If you want to program a feature key, enter before ther

feature key ID (e.g. NIT : *26). Press [MUTE] or

[MESSAGE] to scroll the feature Programmable key

assignments are listed below. To change another key, return to step 3.

5. Press [TRANSFER] to save and exit.

DEFAULT DATA

NX-24E/NX-24B

19: 207 20: 208 21: 209 22: 210 23: 211 24: 212

13: 201 14: 202 15: 203 16: 204 17: 205 18: 206

07: 707 08: 708 09: NONE 10: NONE 11: NONE 12: NONE

01: 701 02: 702 03: 703 04: 704 05: 705 06: 706

NX-12E/NX-12B

07: 201 08: 202 09: 203 10: 204 11: 205 12: 206

01: 701 02: 702 03: 703 04: 704 05: 705 06: 706

NX-6B

01: 701 02: 702 03: 703 04: 704 05: 705 06: 706

AS-30

01: 701 02: 702 03: 703 04: 704 05: 705 06: 706

07: 707 08: 708 09: 709 10: 710 11: 711 12: 712

13: 201 14: 202 15: 203 16: 204 17: 205 18: 206

19: 207 20: 208 21: 209 22: 210 23: 211 24: 212

25: 213 26: 214 27: 215 28: 216 29: 217 30: 218

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 71

SKP-816

09: 201 17: 209 01: 701 02: 702 03: 703 04: 704

10: 202 18: 210 05: 705 06: 706 07: 707 08: 708

11: 203 19: 211

12: 204 20: 212

13: 205 21: 213

14: 206 22: 214

15: 207 23: 215

16: 208 24: 216

NX-AOM

01: NONE 13: NONE

02: NONE 14: NONE

03: NONE 15: NONE

04: NONE 16: NONE

05: NONE 17: NONE

06: NONE 18: NONE

07: NONE 19: NONE

08: NONE 20: NONE

09: NONE 21: NONE

10: NONE 22: NONE

11: NONE 23: NONE

12: NONE 24: NONE

Programmable Key Assignment

00 : ACC Account code 18 : GPC Group Pickup

01 : ALM Set Alarm 19 : HED Headset mode

02 : AMD Answer Mode 20 : IOG Group In/Out

03 : ARD Auto Redial 21 : LNR Last Number Redial

04 : BRG Barge-In 22 : LSN Group Listening

05 : CBK Callback 23 : MPG Meet Me Page

06 : CMP Camp-on 24 : MSG Message

07 : CNF Conference 25 : MUT Mute

08 : DND Do Not Disturb 26 : NIT Night mode

09 : DOR Door 27 : OPR Operator group

10 : DPC Direct Pickup 28 : PAG Page

11 : EXC Boss/Secretary 29 : PSE Pause Dialing

12 : FAT Forced Auto Answer 30 : SNR Saved Number Redial

13 : FLS Flash 31 : SPD Speed Dialing

14 : FWA Call Forward All 32 : TMR Timer

15 : FWB Call Forward Busy 33 : TRN Transfer

16 : FWE External Call Forward 34 : UPC UNA Pickup

17 : FWN Call Forward No answer 35 : VAC Vacant Message

NOTE : The SPD, VAC, PAG, DOR, EXC, DPC, GPC keys can be assigned with

extenders. Refer to MMC 16 KEY EXTENDER.

RELATED MMC

MMC 16 KEY EXTENDER

MMC 72 STATION KEY PROGRAMMING

4Programming 1999.9.15 12:44 PM 페이지65

4Programming 1999.9.15 12:44 PM 페이지66

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 72 STATION KEY PROGRAMMING

This program allows customizing programmable keys on specific electonic keysets on the

system. The program also provides a tool for duplicating data to other keysets to have the

same key format structure. Copy source and target sets must be same type keyset.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 72

2. If you want to copy from another station key

assignment, enter the station number

OR

Press [VOLUME (-) or (+)] to select the station

3. Press the desired key

OR

Press [REDIAL] or [FLASH] to select desired key

4. Press dial pad key number to make selection.

If you want to change another key, return to step 3

5. Press [TRANSFER] to save and exit

DEFAULT DATA

Same as MMC 71

RELATED MMC

MMC 16 KEY EXTENDER

MMC 71 SYSTEM KEY PROGRAMMING

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 73 KEY TEST

This program allows you to check whether each key works properly.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 73

All LEDs light and station rings. Display sets show

the full matrix pattern for 16 characters.

All tri-color LEDs light amber

2. Press each function button and dial pad key to test its

operation. Display sets will show the corresponding

key name. Buttons with LEDs will turn OFF and stay

OFF when pressed

3. Lift the handset to end testing

DEFAULT DATA

NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:44 PM 페이지67

4Programming 1999.9.15 12:44 PM 페이지68

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 80 SYSTEM I/O PARAMETERS

This MMC provides a means of setting parameters for the serial I/O ports to work with SMDR and

Remote MMC. Programming is accomplished easily with the tables below to customize either I/O port.

PARAMETER OPTIONS

TYPE OF SERVICE SMDR, REMOTE, TRAFFIC

REMOTE STN REMOTE only

BAUD RATE 300, 600, 1200, 2400, 4800, 9600 BPS

CHARACTER LENGTH 7 BIT, 8 BIT

PARITY NONE, EVEN, ODD

STOP BIT 1

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 80

Display Shows

2. Press [VOLUME (-) or (+)] to select the serial port

(COM1, COM2) COM1 and COM2 may be found on

SMDR/R-MMC card. COM1 is SMDR and COM2 is

R-MMC. COM1 is used for SMDR or TRAFFIC port and

COM 2 is used for Remote Programming.

3. Press [REDIAL] or [FLASH] to select the parameters

4. Press [MUTE] or [MESSAGE] to select data

5. Press [TRANSFER] to save and exit

DEFAULT DATA

COM1 : 9600 8 NONE

COM2 : 9600 8 NONE

COM1 : XON OFF : ON

COM2 : XON OFF : ON

SMDR : COM1

TRAFFIC : COM1

REMOTE : COM2 STN : NONE

NOTE: “XON OFF” means whether the system checks the CTS pin of the serial

port or not ‘REMOTE STN’ means the port displaying the Remote MMC procedure.

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 81 SMDR OPTIONS

This MMC allows the system administrator to select information to be printed on the SMDR report.

OPTIONS DESCRIPTIONS

PAGE HEADER This option determines whether a page header will print at the top

of each page. Normally turned off if SMDR is sent to a call

accounting machine.

LINE PER PAGE This option selects the length of each page to determine where to print the

SMDR header. The number of lines may be in the range 10 through 99.

INCOMING CALL This option determines whether or not incoming calls will print on SMDR.

AUTHORIZE CODE This option determines whether or not the table of authorization

codes will print on SMDR.

LESS START TIME This option determines whether or not valid calls will include the

minimum call time in total call duration.

ALARM This option determines whether or not stations receiving an alarm

reminder call will print on SMDR.

COMPANY NAME This option allows the system administator to enter a 16 character

name which will appear in the SMDR header.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 81

2. Press [VOLUME (-) or (+)] to select the parameter

3. Press [MUTE] or [MESSAGE] to select data

OR

Using KEYPAD, dial

0 for NO

1 for YES

In case of LINE PER PAGE, enter the line number (17~99)

4. In case of COMPANY NAME, refer to MMC 14

(STATION NAME)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

PAGE HEADER : YES LINE PER PAGE : 66

INCOMING CALL : NO AUTHORIZE CODE : YES

LESS START TIME : NO ALARM : NO

COMPANY NAME : NONE

RELATED MMC

MMC 80 IO PARAMETER

4Programming 1999.9.15 12:44 PM 페이지69

4Programming 1999.9.15 12:44 PM 페이지70

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 83 CALL TRAFFIC REPORT

This MMC is used to print a traffic report and select options. Four types of printing are

available, each with has two options. These are listed below:

NO. TYPE DESCRIPTION

0 NO No print

1 NOW Printed on demand

2 DAILY Printed at the end of day automatically (PM 12:00)

3 WEEKLY Printed at the end of week automatically(PM 12:00 on Saturday)

NO. OPTIONS DESCRIPTION

0 CLEAR A report is printed and all totals are reset to 0

1 SAVE A report is printed and all totals are saved

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 83

2. Press [MUTE] or [MESSAGE] to select type

OR

Using KEYPAD, dial

0 for NO

1 for NOW

2 for DAILY

or 3 for WEEKLY

3. Press [VOLUME] and dial 0 for CLEAR, or 1 for SAVE

You have to select one of the types in step 2 and also

one selection in step 3 to print the traffic report

4. Press [TRANSFER] to save and exit

DEFAULT DATA

PRINT : NO

DATA : SAVE

RELATED MMC

MMC 80 IO PARAMETER

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 90 CUSTOMER USE MMC

Allows the station user access to certain MMCs. For example, it is advised that the user

have access to MMC11 Call Forward, but not MMC60 Toll Deny.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 90.

2. Press [VOLUME (-) o r ( + ) ] to select the MMC you want.

OR

Using KEYPAD, enter the desired MMC number.

3. Press [MUTE] or [MESSAGE] to make selection.

NO : Customer cannot access the MMC.

YES : Customer can access the MMC.

4. Press [TRANSFER] to save and exit.

DEFAULT DATA

00:STN LOCK :YES 41:TRK DIAL :NO

01:STN CODE :YES 42:TRK MISC :NO

10:ANS MODE :YES 43:TRK RING :NO

11:CALL FWD :YES 44:TRK NAME :NO

12:STN MISC :YES 45:TRK GRP :NO

13:RING FREQ :YES 46:DISA LINE :NO

14:STN NAME :YES 50:SYS TIME :NO

15:DATE FORM :YES 51:TONE CADE :NO

16:KEY EXTEN :YES 52:SYS CNTR :NO

17:STN SPD :YES 53:TRK TIME :NO

20:PGM MODE :NO 54:MAKE RATE :NO

21:PGM CODE :YES 55:DATE TIME :YES

22:CUS MISC :YES 56:NITE TIME :YES

23:PAGE ZONE :NO 57:CALL COST :NO

24:BARGE IN :NO 60:TOLL DENY :NO

25:HOT WARM :YES 61:TOLL ALOW :NO

26:ALM CLK :YES 62:PBX CODE :NO

27:VAC MSG :YES 63:AUTH CODE :NO

28:CALL DISC :NO 64:URGENT CD :NO

30:STN COS :NO 65:WILD CHAR :NO

31:TRK USE :NO 66:SPD TOLL :NO

32:INTERCOM :NO 67:SYS SPD :YES

33:DOOR RING :NO 70:NUM PLAN :NO

34:PICK GRP :NO 71:SYS KEY :NO

35:STN GRP :NO 72:STN KEY :NO

36:BOSS SECR :YES 73:KEY TEST :NO

37:SET AOM :NO 80:IO PARA :NO

38:SLT TYPE :NO 81:SMDR OPT :NO

39:DATA LINE :NO 83:TRFC RPT :YES

40:PBX LINE :NO

RELATED MMC

NONE

4Programming 1999.9.15 12:44 PM 페이지71

4Programming 1999.9.15 12:44 PM 페이지72

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 91 SYSTEM VERSION

This MMC provides display of the current software version of the KSU and the KEYSET,

and the date the product was made. This is a READ ONLY MMC.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 91

2. Press [VOLUME (-) or (+)] to select a display

3. Press [TRANSFER] to and exit.

DEFAULT DATA

RELATED MMC

NONE

MMC 92 PORT STATUS

This MMC displays the sixteen(16) port attributes:

IDLE, BUSY, CALLBACK, DOOR RING, TRK RING, STN RING, GRP RING, RCL RING, PROGRAM,

ON T HOLD, ON S HOLD, ON E HOLD, IS PAGED, IS SEIZED, WRAP UP, OFF HOOK.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 92

2. Press [VOLUME (-) or (+)] and to see the port status.

3. To clear the port status, press [HOLD]

4. Press [TRANSFER] to save and exit.

DEFAULT DATA

IDLE

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 93 LANGUAGE SELECTION

Used to select one of three (3) languages to display in keyset LCDs.

Choose an entry number from the table below:

ENTRY NUMBER LANGUAGE

1 ENGLISH

2 SPANISH

3 PORTUGUESE

NOTE : English is displayed while in MMC mode.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 93

Display shows...

2. Press [MUTE] or [MESSAGE] to select a language.

OR

Using KEYPAD, dial

1 for ENGLISH

2 for SPANISH

or 3 for PORTUGUESE

3. Press [TRANSFER] to save and exit.

DEFAULT DATA

ENGLISH

RELATED MMC

NONE

4Programming 1999.9.15 12:44 PM 페이지73

4Programming 1999.9.15 12:44 PM 페이지74

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 94 HALT PROCESS

Use only in the event that all data processing must be stopped.

The four-digit Technician Passcode is required to access this MMC. This MMC will not

interfere with any call in progress, but attempting a new call will result in a busy tone.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 94

2. Enter Technician passcode.

3. Press [MUTE] or [MESSAGE] to select data.

OR

Using KEYPAD, dial

0 for PROCESSING

1 for HALT

4. Press [TRANSFER] to save and exit.

DEFAULT DATA

PROCESSING

RELATED MMC

NONE

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION

MMC 95 SYSTEM RESTART

Provides two methods of restarting the system.

OPTIONS DESCRIPTION

RESET SYSTEM Restart the system only.

CLEAR MEMORY Restart the system and clear all memory and set all

functions to their default values.

Extreme care should be taken when using this MMC. If the system is restarted, all

voice/data connections are dropped. Clearing memory will delete all customer data and

system returns to default status.

PROCEDURE LCD DISPLAY

1. Press [TRANSFER] and dial 95

2. Enter the technician passcode.

3. Press [VOLUME (-) or (+)] to select the option.

OR

Using KEYPAD, dial

0 for NO

or 1 for YES.

If case of CLEAR MEMORY, dial 0 for NO or 1

for YES to remind you of your choice.

DEFAULT DATA

NONE

RELATED MMC

NONE

4Programming 1999.9.15 12:44 PM 페이지75

4Programming 1999.9.15 12:44 PM 페이지76

NX-SERIESHYBRID KEY SYSTEM PROGRAMMING SECTION