Samsung NX-308: INSTALLATION SECTION

INSTALLATION SECTION: Samsung NX-308

INSTALLATION

SECTION

2INSTALL 1999.9.15 12:45 PM 페이지1

2INSTALL 1999.9.15 12:45 PM 페이지2

2INSTALL 1999.9.15 12:45 PM 페이지4

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

4 MDF CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9

4.1 Clip type MDF Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19

4.2 Using to Cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19

5. CONNECTING TELEPHONE LINES . . . . . . . . . . . . . . . . . . . . . 2-20

5.1 SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20

5.2 LOOP START LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20

6. CONNECTING STATION EQUIPMENT . . . . . . . . . . . . . . . . . . 2-20

6.1 CONNECTING KEYSET / AOM . . . . . . . . . . . . . . . . . . . . . . . . 2-20

6.1.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20

6.1.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

6.1.3 NX-1232 Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

6.2 CONNECTING Single-Line Tel. . . . . . . . . . . . . . . . . . . . . . . . . 2-21

6.2.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

6.2.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

6.2.3 NX-1232 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

7. CONNECTING OPTIONAL EQUIPMENT . . . . . . . . . . . . . . . . 2-27

7.1 EXTERNAL MUSIC SOURCE . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

7.2 EXTERNAL PAGING FOR STANDARD . . . . . . . . . . . . . . . . . 2-27

7.3 DOORPHONE AND DOOR LOCK RELEASE . . . . . . . . . . . . 2-28

7.4 SMDR / REMOTE PROGRAMMING . . . . . . . . . . . . . . . . . . . . 2-29

7.5 POWER FAILURE TRANSFER . . . . . . . . . . . . . . . . . . . . . . . . 2-31

7.5.1 NX-308 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

7.5.2 NX-820 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

7.5.3 NX-1232 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

7.6 EXTERNAL BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

8. BEFORE POWER UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32

9 INSTALLING TO KEYSET . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33

9-1 CONNECTING TO LINE CORD . . . . . . . . . . . . . . . . . . . . . . . .2-33

9-2 WALL-MOUNTING A KEYSET . . . . . . . . . . . . . . . . . . . . . . . . .2-33

9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET .2-34

2INSTALL 1999.9.15 12:45 PM 페이지6

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

FIGURE 2-1 MOUNTING THE KSU

2.3 AC Power Selection ( See FIGURE 2-2 )

Before pluging in the KSU, set the AC power selection connector.

The Power board of each system has three power connectors. One is for 0V

(Ground) and the rest are for 110V/220V selection. The KSU has two lines; one

black and the other sky-blue (or white); with a pink power connection jack.

Verify the AC voltage and connect the sky-blue (or white) line to the 0V connector,

and black to the AC power connector.

Connect the BLACK wire to

110VAC or 220VAC power(LIVE).

Connect the S K Y - B L U E ( o r

w h i t e )wire to 0V (NEUTRAL)

Connect the GREEN-YELLOW (or

green) line to FRAME GROUND

FIGURE 2-2 AC POWER SELECTION

2 - 2

2INSTALL 1999.9.15 12:45 PM 페이지8

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

3. INSTALLATION EXPANSION CARDS & OPTION

BOARDS

Unpack and inspect each card before installing. Check for signs of physical damage.

If any damage is detected, do not attempt to install.

3.1 NX-2TRK Card ( See FIGURE 3 - 1 )

Insert the NX-2TRK Card into any expansion slot. Push firmly to ensure that it is

fully inserted into the backplane connector.

3.2 NX-4TRK Card ( See FIGURE 3 - 1 )

Insert the NX-4TRK Card into any expansion slot. Push firmly to ensure that it is

fully inserted into the backplane connector.

3.3 NX-4KLI Card ( See FIGURE 3 - 2 )

Insert the NX-4KLI Card into any expansion slot. Push firmly to ensure that it is

fully inserted into the backplane connector.

FIGURE 3-1 NX-2/4 TRK CARD FIGURE 3-2 NX-4KLI CARD

3.4 NX-4SLI Card ( See FIGURE 3 - 3)

Insert the NX-4SLI Card into any expansion slot. Push firmly to ensure that it is

fully inserted into the backplane connector.

3.5 NX-4OPX Card ( See FIGURE 3 - 4 )

Insert the NX-4OPX Card into any expansion slot. Push firmly to ensure that it is

fully inserted into the backplane connector.

2 - 4

2INSTALL 1999.9.15 12:45 PM 페이지10

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

3.8 NX-SMDR/R-MMC Board ( See FIGURE 3 - 7 )

Install the NX-SMDR/R-MMC board on the bottom of the base board.

3.9 NX-DPH/PAGING Board ( See FIGURE 3 - 8 )

Install the NX-DPH/PAGING board on the middle of the base board.

FIGURE 3-7 NX-SMDR/R-MMC BOARD FIGURE 3-8 NX-DPH/PAGING BOARD

3.10 NX-MPD Board ( See FIGURE 3 - 9 )

Install the NX-MPD board on the bottom of the base board.

3.11 NX-PRS Board ( See FIGURE 3 - 10 )

Install the NX-PRS board on the bottom of the base board.

FIGURE 3-9 NX-MPD BOARD FIGURE 3-10 NX-PRS BOARD

2 - 6

2INSTALL 1999.9.15 12:45 PM 페이지12

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

3.13.2 NX-820 SYSTEM ( See FIGURE 3-13)

NX-820 system can have up to three expansion cards under the base

board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS

option boards are installed on the surface of Base board.

NX-MPD or NX-PRS Board.

NX-820 system has two

NX-DPH/PAGING Board

connectors.

SUPPORT

NX-SMDR/R-MMC

Board

NX-820 Base Board

MDF Cards

Three Expansion Cards in any slot. Push

firmly to ensure that it is fully inserted into the

back plane connector on the connection

b o a r d .

FIGURE 3-13 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-820

3.13.3 NX-1232 SYSTEM ( See FIGURE 3-14 )

NX-1232 system can have up to three expansion cards under the base

board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS

option boards are installed on the surface of Base board.

NX-MPD or NX-PRS Board.

NX-1232 system has four

NX-DPH/PAGING Board

connectors.

SUPPORT

NX-SMDR/R-MMC

Board

NX-1232 Base Board

Three Expansion Cards in any slot. Push

MDF Cards

firmly to ensure that it is fully inserted into the

back plane connector on the connection

b o a r d .

FIGURE 3-14 INSTALLING EXPANSION CARD & OPTION BD FOR NX-1232

2 - 8

2INSTALL 1999.9.15 12:45 PM 페이지14

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

P1

PIN NO. COLOR MDFA-C FUNCTION

1 BL-W R1 1 C.O.1 TIP

26 W-BL R2 1 RING

2 O-W R1 2 C.O.2 TIP

27 W-O R2 2 RING

3 GN-W R1 3 C.O.3 TIP

28 W-GN R2 3 RING

4 BR-W R1 4

RESERVED

29 W-BR R2 4

5 S-W

X NC

30 W-S

6 BL-R R1 5 STN1 L1

31 R-BL R2 5 L2

7 O-R R1 6 STN1 D+

32 R-O R2 6 D-

8 GR-R R1 7 STN2 L1

33 R-GR R2 7 L2

9 BR-R R1 8 STN2 D+

34 R-BR R2 8 D-

10 S-R R1 9 STN3 L1

35 R-S R2 9 L2

11 BL-BK R1 10 STN3 D+

36 BK-BL R2 10 D-

12 O-BK R1 11 STN4 L1

37 BK-O R2 11 L2

13 GR-BK R1 12 STN4 D+

38 BK-GR R2 12 D-

14 BR-BK R1 13 STN5 L1

39 BK-BR R2 13 L2

15 S-BK R1 14 STN5 D+

40 BK-S R2 14 D-

16 BL-Y R1 15 STN6 L1

41 Y-BL R2 15 L2

17 S-Y R1 16 STN6 D+

42 Y-S R2 16 D-

18 GR-Y R1 17 STN7 L1

43 Y-GR R2 17 L2

19 BR-Y R1 18 STN7 D+

44 Y-BR R2 18 D-

20 S-Y R1 19 STN8 L1

45 Y-S R2 19 L2

21 BL-VL R1 20 STN8 D+

46 VL-BL R2 20 D-

22 O-VL

X NC

47 VL-O

23 GR-VL

X NC

48 VL-GR

24 BR-VL

X NC

49 VL-BR

25 S-VL

X NC

50 VL-S

FIGURE 4-1 MDFA-C CONNECTIONS FOR NX-308

2 - 10

2INSTALL 1999.9.15 12:45 PM 페이지16

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

P1

CLIP

PIN NO. COLOR MDFB-C FUNCTION

1 BL-W R1 1 C.O.1 TIP CLIP 1

26 W-BL R2 1 RING

2 O-W R1 2 C.O.2 TIP

27 W-O R2 2 RING

3 GN-W R1 3 C.O.3 TIP

28 W-GN R2 3 RING

4 BR-W R1 4 C.O.4 TIP

29 W-BR R2 4 RING

5 S-W

X NC

30 W-S

6 BL-R R1 1 STN1 L1

31 R-BL R2 1 L2 CLIP 2

7 O-R R1 2 STN1 D+

32 R-O R2 2 D-

8 GR-R R1 3 STN2 L1

33 R-GR R2 3 L2

9 BR-R R1 4 STN2 D+

34 R-BR R2 4 D-

10 S-R R1 5 STN3 L1

35 R-S R2 5 L2

11 BL-BK R1 6 STN3 D+

36 BK-BL R2 6 D-

12 O-BK R1 7 STN4 L1

37 BK-O R2 7 L2

13 GR-BK R1 8 STN4 D+

38 BK-GR R2 8 D-

14 BR-BK R1 9 STN5 L1

39 BK-BR R2 9 L2

15 S-BK R1 10 STN5 D+

40 BK-S R2 10 D-

16 BL-Y R1 11 STN6 L1

41 Y-BL R2 11 L2

17 S-Y R1 12 STN6 D+

42 Y-S R2 12 D-

18 GR-Y R1 13 STN7 L1

43 Y-GR R2 13 L2

19 BR-Y R1 14 STN7 D+

44 Y-BR R2 14 D-

20 S-Y R1 15 STN8 L1

45 Y-S R2 15 L2

21 BL-VL R1 16 STN8 D+

46 VL-BL R2 16 D-

22 O-VL R1 17 STN9 L1

47 VL-O R2 17 L2

23 GR-VL R1 18 STN10 L1

48 VL-GR R2 18 L2

24 BR-VL R1 19 STN11 L1

49 VL-BR R2 19 L2

25 S-VL R1 20 STN12 L1

50 VL-S R2 20 L2

FIGURE 4-3 MDFB-C CONNECTIONS FOR NX-820

2 - 12

2INSTALL 1999.9.15 12:45 PM 페이지18

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

P1 P2

PIN NO. COLOR CLIP 1 FUNCTION CLIP 2 FUNCTION

1 BL-W R1 1 C.O.1 TIP R1 1 STN5 L1

26 W-BL R2 1 RING R2 1 L2

2 O-W R1 2 C.O.2 TIP R1 2 STN5 D+

27 W-O R2 2 RING R2 2 D-

3 GN-W R1 3 C.O.3 TIP R1 3 STN6 L1

28 W-GN R2 3 RING R2 3 L2

4 BR-W R1 4 C.O.4 TIP R1 4 STN6 D+

29 W-BR R2 4 RING R2 4 D-

5 S-W R1 5 C.O.5 TIP R1 5 STN7 L1

30 W-S R2 5 RING R2 5 L2

6 BL-R R1 6 C.O.6 TIP R1 6 STN7 D+

31 R-BL R2 6 RING R2 6 D-

7 O-R R1 7 C.O.7 TIP R1 7 STN8 L1

32 R-O R2 7 RING R2 7 L2

8 GR-R R1 8 C.O.8 TIP R1 8 STN8 D+

33 R-GR R2 8 RING R2 8 D-

9 BR-R R1 9

R1 9

NC

NC

34 R-BR R2 9 R2 9

10 S-R R1 10

R1 10

NC

NC

35 R-S R2 10 R2 10

11 BL-BK R1 11

R1 11

NC

NC

36 BK-BL R2 11 R2 11

12 O-BK R1 12

R1 12

NC

NC

37 BK-O R2 12 R2 12

13 GR-BK R1 13 STN1 L1 R1 13 STN9 L1

38 BK-GR R2 13 L2 R2 13 L2

14 BR-BK R1 14 STN1 D+ R1 14 STN10 L1

39 BK-BR R2 14 D- R2 14 L2

15 S-BK R1 15 STN2 L1 R1 15 STN11 L1

40 BK-S R2 15 L2 R2 15 L2

16 BL-Y R1 16 STN2 D+ R1 16 STN12 L1

41 Y-BL R2 16 D- R2 16 L2

17 S-Y R1 17 STN3 L1 R1 17 STN13 L1

42 Y-S R2 17 L2 R2 17 L2

18 GR-Y R1 18 STN3 D+ R1 18 STN14 L1

43 Y-GR R2 18 D- R2 18 L2

19 BR-Y R1 19 STN4 L1 R1 19 STN15 L1

44 Y-BR R2 19 L2 R2 19 L2

20 S-Y R1 20 STN4 D+ R1 20 STN16 L1

45 Y-S R2 20 D- R2 20 L2

21 BL-VL

X NC X NC

46 VL-BL

22 O-VL

X

X

47 VL-O

23 GR-VL

X

X

48 VL-GR

24 BR-VL

X

X

49 VL-BR

25 S-VL

X

X

50 VL-S

FIGURE 4-5 MDFC-C CONNECTIONS FOR NX-1232

2 - 14

2INSTALL 1999.9.15 12:45 PM 페이지20

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

50 PIN CHAMP

CONNECTOR

2 TRK 4TRK 4KLI 4 SLI 8 KLI 8 SLI 4 OPX

PIN NO. COLOR M D F D - M FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION

1 BL-W R1 1 C.O.1 TIP C.O.1 TIP STN1 L1 STN1 L1 STN1 L1 STN1 L1 STN1 L1

26 W-BL R2 1 R I N G RING L2 L2 L2 L2 L2

2 O-W R1 2

STN1 D+

STN1 D+

R E S E R V E D R E S E R V E D

R E S E R V E D

R E S E R V E D R E S E R V E D

27 W-O R2 2 D- D-

3 GN-W R1 3 C.O.2 TIP C.O.2 TIP STN2 L1 STN2 L1 STN2 L1 STN2 L1 STN2 L1

28 W-GN R2 3 RING RING L2 L2 L2 L2 L2

4 BR-W R1 4

STN2 D+

STN2 D+

R E S E R V E D R E S E R V E D

R E S E R V E D

R E S E R V E D R E S E R V E D

29 W-BR R2 4 D- D-

5 S-W R1 5

C.O.3 TIP STN3 L1 STN3 L1 STN3 L1 STN3 L1 STN3 L1

30 W-S R2 5 RING L2 L2 L2 L2 L2

6 BL-R R1 6

STN3 D+

STN3 D+

R E S E R V E D

R E S E R V E D

R E S E R V E D R E S E R V E D

31 R-BL R2 6 D- D-

7 O-R R1 7

C.O.4 TIP STN4 L1 STN4 L1 STN4 L1 STN4 L1 STN4 L1

32 R-O R2 7 RING L2 L2 L2 L2 L2

8 GR-R R1 8

STN4 D+

STN4 D+

R E S E R V E D

R E S E R V E D

R E S E R V E D R E S E R V E D

33 R-GR R2 8 D- D-

9 BR-R R1 9

STN5 L1 STN5 L1

R E S E R V E D

34 R-BR R2 9 L2 L2

10 S-R R1 10

STN5 D+

R E S E R V E D

35 R-S R2 10 D-

11 BL-BK R1 11

STN6 L1 STN6 L1

36 BK-BL R2 11 L2 L2

12 O-BK R1 12

STN6 D+

R E S E R V E D

37 BK-O R2 12 D-

13 GR-BK R1 13

STN7 L1 STN7 L1

38 BK-GR R2 13 L2 L2

14 BR-BK R1 14

STN7 D+

R E S E R V E D

39 BK-BR R2 14 D-

15 S-BK R1 15

STN8 L1 STN8 L1

40 BK-S R2 15 L2 L2

16 BL-Y R1 16

STN8 D+

R E S E R V E D

41 Y-BL R2 16 D-

17 S-Y

X NC NC NC NC NC NC NC

42 Y-S

18 GR-Y

X

43 Y-GR

19 BR-Y

X

44 Y-BR

20 S-Y

X

45 Y-S

21 BL-VL

X

46 VL-BL

22 O-VL

X

47 VL-O

23 GR-VL

X

48 VL-GR

24 BR-VL

X

49 VL-BR

25 S-VL

X

50 VL-S

FIGURE 4-7 MDFD-C CONNECTIONS(EXPANSION CARD)

2 - 16

2INSTALL 1999.9.15 12:45 PM 페이지22

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

MDF Pin No. Champ Pin No. MDF Pin No. Champ Pin No. MDF Pin No. Champ Pin No.

1 26 21 36 41 46

2 1 22 11 42 21

3 27 23 37 43 47

4 2 24 12 44 22

5 28 25 38 45 48

6 3 26 13 46 23

7 29 27 39 47 49

8 4 28 14 48 24

9 30 29 40 49 50

10 5 30 15 50 25

11 31 31 41 51 RESERVED

12 6 32 16 52 RESERVED

13 32 33 42 53 RESERVED

14 7 34 17 54 RESERVED

15 33 35 43 55 RESERVED

16 8 36 18 56 RESERVED

17 34 37 44 57 RESERVED

18 9 38 19 58 RESERVED

19 35 39 45 59 RESERVED

20 10 40 20 60 RESERVED

FIGURE 4-9 OPTIONAL MDF

2 - 18

2INSTALL 1999.9.15 12:45 PM 페이지24

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

5. CONNECTING TELEPHONE LINES

5.1 SAFETY PRECAUTIONS

To limit the risk of personal injury, always follow these precautions before

connecting to TELCO circuits:

Never install telephone wiring during a lightning storm.

Never install telephone jacks in a wet location unless the jack is specifically

designed for wet locations.

Never touch uninsulated telephone wires or terminals unless the telephone line

has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

5.2 LOOP START LINES

Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each

loop start C.O. line to the trunk port.

Refer to FIGURE 4-1 through 4-7 and 4-8.

6. CONNECTING STATION EQUIPMENT

Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each

keyset/AOM or single-line telephone to the keyset port or SLI port of your choice.

6.1 CONNECTING KEYSET / AOM (FIGURE 6-1)

The NX-308 system has seven hybrid ports and the NX-1232 system has eight

hybrid ports.Either a keyset or a single-line telephone may be connected to a

hybrid port. Before connecting station equipment to a hybrid port, the switches on

the Base Board must be set to keyset or SLT.

Each switch is composed of four sections, set to ON/ON/OFF/OFF to connect a

keyset to the hybrid port.

ON

Each numbered switch has four

sections: .

To connect a keyset to a hybrid port,

they are set to ON/ ON/ OFF/ OFF.

OFF

6.1.1 NX-308 - Related Switch Location (FIGURE 6-3)

To connect a keyset or AOM to station #2 to #8 of basic KSU, the related

DIP switches should be set as follows: (Station #1 is a keyset-only station.)

2 - 20

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

6.2.1 NX-308 - Related Switch Location (FIGURE 6-3)

To connect the single line telephone to the any station from #2 to #8 of basic

KSU, the related DIP switches should be set as follows.

Station No. Releated DIP Switches Setting

STN 2 SW 1 OFF OFF ON ON

STN 3 SW 2 OFF OFF ON ON

STN 4 SW 3 OFF OFF ON ON

S

STN 5 SW 4 OFF OFF ON ON

STN 6 SW 5 OFF OFF ON ON

STN 7 SW 6 OFF OFF ON ON

STN 8 SW 7 OFF OFF ON ON

6.2.2 NX-820

To connect a single-line telephone to the from #5 to #12 of basic KSU.

6.2.3 NX-1232 - Related Switch Location (FIGURE 6-5)

To connect a single line telephone to any station from #1 to #16 of basic KSU.

Station No. Releated DIP Switches Setting

STN 1 SW 8 OFF OFF ON ON

STN 2 SW 7 OFF OFF ON ON

STN 3 SW 6 OFF OFF ON ON

STN 4 SW 5 OFF OFF ON ON

S

STN 5 SW 4 OFF OFF ON ON

STN 6 SW 3 OFF OFF ON ON

STN 7 SW 2 OFF OFF ON ON

STN 8 SW 1 OFF OFF ON ON

2 - 22

2INSTALL 1999.9.15 12:45 PM 페이지26

2INSTALL 1999.9.15 12:45 PM 페이지28

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

Music Source Selection

shunt pin

PFT selection

switch

Hybrid station selection

switches

Memory Back-up

enable shunt pin

󱅎

Hybrid Station Configuration

KTS : SLT :

FIGURE 6-3 NX-308 KSU SWITCH LOCATIONS

2 - 24

2INSTALL 1999.9.15 12:45 PM 페이지30

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

Music Source Selection

shunt pin

Memory Back-up

enable shunt pin

Hybrid station selection

switches

󱅎 Hybrid Station Configuration

KTS : SLT :

FIGURE 6-5 NX-1232 KSU SWITCH LOCATIONS

2 - 26

2INSTALL 1999.9.15 12:45 PM 페이지32

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

7.3 DOORPHONE AND DOOR LOCK RELEASE (See FIGURE 7-3)

System users have the capability of communicating with an optional door phone

when the N X - D P H / P A G I N G board is installed. A maximum of two door phones

may be installed per system.

To connect the door phone, plug a two-pair modular cable into the connector on

the KSU marked DOOR1 or DOOR2.

To connect the customer-provided electric door lock unit for control of the door

lock release mechanism, plug a one-pair modular cable into the connector on the

KSU marked LOCKER1 or LOCKER2.

FIGURE 7-3 CONNECTING DOOR PHONE & DOOR LOCK RELEASE

2 - 28

2INSTALL 1999.9.15 12:45 PM 페이지34

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

R-MMC PC

(9 PIN) (9 PIN)

RXD 2 2 RXD

TXD 3 3 TXD

DTR 4 4 DTR

SGND 5 5 SGND

CTS 8

NOTE : If the CTS pin is not connected, the system cannot check the printer

(MODEM) status (power ON/OFF, paper empty, etc.)

FIGURE 7-4 SMDR & REMOTE PROGRAMMING CONNECTIONS

2 - 30

2INSTALL 1999.9.15 12:45 PM 페이지36

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

FIGURE 7-5 CONNECTING EXTERNAL BATTERY

8. BEFORE POWER UP

During initial installation, it is best to verify proper system operation before plugging in

any amphenol-type cables to the MDF. If you have already plugged the cables in,

unplug them. Verify that the AC voltage at the dedicated electric outlet is correct.

Make sure the AC power switch is in the OFF position and memory back-up switch is

ON. Plug the KSU power cord into the dedicated polarized AC outlet. Turn the AC

power switch to the ON position, and verify the status of the "POWER", "MONITOR",

and "IDLE" LEDs on the cover of the KSU. A steady "POWER" LED indicates the

presence of power, and a blinking "MONITOR" LED indicates that the main

processor is functioning. A steady "IDLE" LED indicates that no one is using the

system. If the "POWER" LED fails to illuminate, unplug the system, remove the power

supply, and check the AC fuse located on the bottom.

If the fuse is good but the "POWER" LED does not illuminate, you must correct the

problem before continuing., Turn off the power switch., Unplug all expansion cards

except Base board. Turn the system on. Check the "POWER" LED again. If the

problem is corrected, you have a defective card. Test and remove the faulty card

before continuing.

If the LED still does not light, unplug the KSU and change power supplies or Base

board. This in all probability will solve the problem. If it does not, contact Samsung

Technical Support.

2 - 32

2INSTALL 1999.9.15 12:45 PM 페이지38

NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION

9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET

Driver

Insert the sharp-edged one

(ex:driver, pincette,...) into the

slight gap of handset.

Line holder

Slightly push the driver, and lift

up the line holder from handset.

󱅎 Now, you have removed the line holder, and can see the modular

jack of the handset cord.

2 - 34