Samsung NX-308: INSTALLATION SECTION
INSTALLATION SECTION: Samsung NX-308
INSTALLATION
SECTION
2INSTALL 1999.9.15 12:45 PM 페이지1
2INSTALL 1999.9.15 12:45 PM 페이지2
2INSTALL 1999.9.15 12:45 PM 페이지4
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
4 MDF CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
4.1 Clip type MDF Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
4.2 Using to Cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
5. CONNECTING TELEPHONE LINES . . . . . . . . . . . . . . . . . . . . . 2-20
5.1 SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
5.2 LOOP START LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
6. CONNECTING STATION EQUIPMENT . . . . . . . . . . . . . . . . . . 2-20
6.1 CONNECTING KEYSET / AOM . . . . . . . . . . . . . . . . . . . . . . . . 2-20
6.1.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
6.1.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
6.1.3 NX-1232 Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
6.2 CONNECTING Single-Line Tel. . . . . . . . . . . . . . . . . . . . . . . . . 2-21
6.2.1 NX-308 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
6.2.2 NX-820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
6.2.3 NX-1232 - Related Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
7. CONNECTING OPTIONAL EQUIPMENT . . . . . . . . . . . . . . . . 2-27
7.1 EXTERNAL MUSIC SOURCE . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
7.2 EXTERNAL PAGING FOR STANDARD . . . . . . . . . . . . . . . . . 2-27
7.3 DOORPHONE AND DOOR LOCK RELEASE . . . . . . . . . . . . 2-28
7.4 SMDR / REMOTE PROGRAMMING . . . . . . . . . . . . . . . . . . . . 2-29
7.5 POWER FAILURE TRANSFER . . . . . . . . . . . . . . . . . . . . . . . . 2-31
7.5.1 NX-308 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
7.5.2 NX-820 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
7.5.3 NX-1232 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
7.6 EXTERNAL BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
8. BEFORE POWER UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
9 INSTALLING TO KEYSET . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
9-1 CONNECTING TO LINE CORD . . . . . . . . . . . . . . . . . . . . . . . .2-33
9-2 WALL-MOUNTING A KEYSET . . . . . . . . . . . . . . . . . . . . . . . . .2-33
9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET .2-34
2INSTALL 1999.9.15 12:45 PM 페이지6
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
FIGURE 2-1 MOUNTING THE KSU
2.3 AC Power Selection ( See FIGURE 2-2 )
Before pluging in the KSU, set the AC power selection connector.
The Power board of each system has three power connectors. One is for 0V
(Ground) and the rest are for 110V/220V selection. The KSU has two lines; one
black and the other sky-blue (or white); with a pink power connection jack.
Verify the AC voltage and connect the sky-blue (or white) line to the 0V connector,
and black to the AC power connector.
Connect the BLACK wire to
110VAC or 220VAC power(LIVE).
Connect the S K Y - B L U E ( o r
w h i t e )wire to 0V (NEUTRAL)
Connect the GREEN-YELLOW (or
green) line to FRAME GROUND
FIGURE 2-2 AC POWER SELECTION
2 - 2
2INSTALL 1999.9.15 12:45 PM 페이지8
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
3. INSTALLATION EXPANSION CARDS & OPTION
BOARDS
Unpack and inspect each card before installing. Check for signs of physical damage.
If any damage is detected, do not attempt to install.
3.1 NX-2TRK Card ( See FIGURE 3 - 1 )
Insert the NX-2TRK Card into any expansion slot. Push firmly to ensure that it is
fully inserted into the backplane connector.
3.2 NX-4TRK Card ( See FIGURE 3 - 1 )
Insert the NX-4TRK Card into any expansion slot. Push firmly to ensure that it is
fully inserted into the backplane connector.
3.3 NX-4KLI Card ( See FIGURE 3 - 2 )
Insert the NX-4KLI Card into any expansion slot. Push firmly to ensure that it is
fully inserted into the backplane connector.
FIGURE 3-1 NX-2/4 TRK CARD FIGURE 3-2 NX-4KLI CARD
3.4 NX-4SLI Card ( See FIGURE 3 - 3)
Insert the NX-4SLI Card into any expansion slot. Push firmly to ensure that it is
fully inserted into the backplane connector.
3.5 NX-4OPX Card ( See FIGURE 3 - 4 )
Insert the NX-4OPX Card into any expansion slot. Push firmly to ensure that it is
fully inserted into the backplane connector.
2 - 4
2INSTALL 1999.9.15 12:45 PM 페이지10
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
3.8 NX-SMDR/R-MMC Board ( See FIGURE 3 - 7 )
Install the NX-SMDR/R-MMC board on the bottom of the base board.
3.9 NX-DPH/PAGING Board ( See FIGURE 3 - 8 )
Install the NX-DPH/PAGING board on the middle of the base board.
FIGURE 3-7 NX-SMDR/R-MMC BOARD FIGURE 3-8 NX-DPH/PAGING BOARD
3.10 NX-MPD Board ( See FIGURE 3 - 9 )
Install the NX-MPD board on the bottom of the base board.
3.11 NX-PRS Board ( See FIGURE 3 - 10 )
Install the NX-PRS board on the bottom of the base board.
FIGURE 3-9 NX-MPD BOARD FIGURE 3-10 NX-PRS BOARD
2 - 6
2INSTALL 1999.9.15 12:45 PM 페이지12
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
3.13.2 NX-820 SYSTEM ( See FIGURE 3-13)
NX-820 system can have up to three expansion cards under the base
board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS
option boards are installed on the surface of Base board.
NX-MPD or NX-PRS Board.
NX-820 system has two
NX-DPH/PAGING Board
connectors.
SUPPORT
NX-SMDR/R-MMC
Board
NX-820 Base Board
MDF Cards
Three Expansion Cards in any slot. Push
firmly to ensure that it is fully inserted into the
back plane connector on the connection
b o a r d .
FIGURE 3-13 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-820
3.13.3 NX-1232 SYSTEM ( See FIGURE 3-14 )
NX-1232 system can have up to three expansion cards under the base
board. And NX-SMDR/R-MMC, NX-DPH/PAGING, NX-MPD and NX-PRS
option boards are installed on the surface of Base board.
NX-MPD or NX-PRS Board.
NX-1232 system has four
NX-DPH/PAGING Board
connectors.
SUPPORT
NX-SMDR/R-MMC
Board
NX-1232 Base Board
Three Expansion Cards in any slot. Push
MDF Cards
firmly to ensure that it is fully inserted into the
back plane connector on the connection
b o a r d .
FIGURE 3-14 INSTALLING EXPANSION CARD & OPTION B’D FOR NX-1232
2 - 8
2INSTALL 1999.9.15 12:45 PM 페이지14
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
50 PIN CHAMP
CONNECTOR
P1
PIN NO. COLOR MDFA-C FUNCTION
1 BL-W R1 1 C.O.1 TIP
26 W-BL R2 1 RING
2 O-W R1 2 C.O.2 TIP
27 W-O R2 2 RING
3 GN-W R1 3 C.O.3 TIP
28 W-GN R2 3 RING
4 BR-W R1 4
RESERVED
29 W-BR R2 4
5 S-W
X NC
30 W-S
6 BL-R R1 5 STN1 L1
31 R-BL R2 5 L2
7 O-R R1 6 STN1 D+
32 R-O R2 6 D-
8 GR-R R1 7 STN2 L1
33 R-GR R2 7 L2
9 BR-R R1 8 STN2 D+
34 R-BR R2 8 D-
10 S-R R1 9 STN3 L1
35 R-S R2 9 L2
11 BL-BK R1 10 STN3 D+
36 BK-BL R2 10 D-
12 O-BK R1 11 STN4 L1
37 BK-O R2 11 L2
13 GR-BK R1 12 STN4 D+
38 BK-GR R2 12 D-
14 BR-BK R1 13 STN5 L1
39 BK-BR R2 13 L2
15 S-BK R1 14 STN5 D+
40 BK-S R2 14 D-
16 BL-Y R1 15 STN6 L1
41 Y-BL R2 15 L2
17 S-Y R1 16 STN6 D+
42 Y-S R2 16 D-
18 GR-Y R1 17 STN7 L1
43 Y-GR R2 17 L2
19 BR-Y R1 18 STN7 D+
44 Y-BR R2 18 D-
20 S-Y R1 19 STN8 L1
45 Y-S R2 19 L2
21 BL-VL R1 20 STN8 D+
46 VL-BL R2 20 D-
22 O-VL
X NC
47 VL-O
23 GR-VL
X NC
48 VL-GR
24 BR-VL
X NC
49 VL-BR
25 S-VL
X NC
50 VL-S
FIGURE 4-1 MDFA-C CONNECTIONS FOR NX-308
2 - 10
2INSTALL 1999.9.15 12:45 PM 페이지16
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
50 PIN CHAMP
CONNECTOR
P1
CLIP
PIN NO. COLOR MDFB-C FUNCTION
1 BL-W R1 1 C.O.1 TIP CLIP 1
26 W-BL R2 1 RING
2 O-W R1 2 C.O.2 TIP
27 W-O R2 2 RING
3 GN-W R1 3 C.O.3 TIP
28 W-GN R2 3 RING
4 BR-W R1 4 C.O.4 TIP
29 W-BR R2 4 RING
5 S-W
X NC
30 W-S
6 BL-R R1 1 STN1 L1
31 R-BL R2 1 L2 CLIP 2
7 O-R R1 2 STN1 D+
32 R-O R2 2 D-
8 GR-R R1 3 STN2 L1
33 R-GR R2 3 L2
9 BR-R R1 4 STN2 D+
34 R-BR R2 4 D-
10 S-R R1 5 STN3 L1
35 R-S R2 5 L2
11 BL-BK R1 6 STN3 D+
36 BK-BL R2 6 D-
12 O-BK R1 7 STN4 L1
37 BK-O R2 7 L2
13 GR-BK R1 8 STN4 D+
38 BK-GR R2 8 D-
14 BR-BK R1 9 STN5 L1
39 BK-BR R2 9 L2
15 S-BK R1 10 STN5 D+
40 BK-S R2 10 D-
16 BL-Y R1 11 STN6 L1
41 Y-BL R2 11 L2
17 S-Y R1 12 STN6 D+
42 Y-S R2 12 D-
18 GR-Y R1 13 STN7 L1
43 Y-GR R2 13 L2
19 BR-Y R1 14 STN7 D+
44 Y-BR R2 14 D-
20 S-Y R1 15 STN8 L1
45 Y-S R2 15 L2
21 BL-VL R1 16 STN8 D+
46 VL-BL R2 16 D-
22 O-VL R1 17 STN9 L1
47 VL-O R2 17 L2
23 GR-VL R1 18 STN10 L1
48 VL-GR R2 18 L2
24 BR-VL R1 19 STN11 L1
49 VL-BR R2 19 L2
25 S-VL R1 20 STN12 L1
50 VL-S R2 20 L2
FIGURE 4-3 MDFB-C CONNECTIONS FOR NX-820
2 - 12
2INSTALL 1999.9.15 12:45 PM 페이지18
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
50 PIN CHAMP
CONNECTOR
P1 P2
PIN NO. COLOR CLIP 1 FUNCTION CLIP 2 FUNCTION
1 BL-W R1 1 C.O.1 TIP R1 1 STN5 L1
26 W-BL R2 1 RING R2 1 L2
2 O-W R1 2 C.O.2 TIP R1 2 STN5 D+
27 W-O R2 2 RING R2 2 D-
3 GN-W R1 3 C.O.3 TIP R1 3 STN6 L1
28 W-GN R2 3 RING R2 3 L2
4 BR-W R1 4 C.O.4 TIP R1 4 STN6 D+
29 W-BR R2 4 RING R2 4 D-
5 S-W R1 5 C.O.5 TIP R1 5 STN7 L1
30 W-S R2 5 RING R2 5 L2
6 BL-R R1 6 C.O.6 TIP R1 6 STN7 D+
31 R-BL R2 6 RING R2 6 D-
7 O-R R1 7 C.O.7 TIP R1 7 STN8 L1
32 R-O R2 7 RING R2 7 L2
8 GR-R R1 8 C.O.8 TIP R1 8 STN8 D+
33 R-GR R2 8 RING R2 8 D-
9 BR-R R1 9
R1 9
NC
NC
34 R-BR R2 9 R2 9
10 S-R R1 10
R1 10
NC
NC
35 R-S R2 10 R2 10
11 BL-BK R1 11
R1 11
NC
NC
36 BK-BL R2 11 R2 11
12 O-BK R1 12
R1 12
NC
NC
37 BK-O R2 12 R2 12
13 GR-BK R1 13 STN1 L1 R1 13 STN9 L1
38 BK-GR R2 13 L2 R2 13 L2
14 BR-BK R1 14 STN1 D+ R1 14 STN10 L1
39 BK-BR R2 14 D- R2 14 L2
15 S-BK R1 15 STN2 L1 R1 15 STN11 L1
40 BK-S R2 15 L2 R2 15 L2
16 BL-Y R1 16 STN2 D+ R1 16 STN12 L1
41 Y-BL R2 16 D- R2 16 L2
17 S-Y R1 17 STN3 L1 R1 17 STN13 L1
42 Y-S R2 17 L2 R2 17 L2
18 GR-Y R1 18 STN3 D+ R1 18 STN14 L1
43 Y-GR R2 18 D- R2 18 L2
19 BR-Y R1 19 STN4 L1 R1 19 STN15 L1
44 Y-BR R2 19 L2 R2 19 L2
20 S-Y R1 20 STN4 D+ R1 20 STN16 L1
45 Y-S R2 20 D- R2 20 L2
21 BL-VL
X NC X NC
46 VL-BL
22 O-VL
X
”
X
”
47 VL-O
23 GR-VL
X
”
X
”
48 VL-GR
24 BR-VL
X
”
X
”
49 VL-BR
25 S-VL
X
”
X
”
50 VL-S
FIGURE 4-5 MDFC-C CONNECTIONS FOR NX-1232
2 - 14
2INSTALL 1999.9.15 12:45 PM 페이지20
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
50 PIN CHAMP
CONNECTOR
2 TRK 4TRK 4KLI 4 SLI 8 KLI 8 SLI 4 OPX
PIN NO. COLOR M D F D - M FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION FUNCTION
1 BL-W R1 1 C.O.1 TIP C.O.1 TIP STN1 L1 STN1 L1 STN1 L1 STN1 L1 STN1 L1
26 W-BL R2 1 R I N G RING L2 L2 L2 L2 L2
2 O-W R1 2
STN1 D+
STN1 D+
R E S E R V E D R E S E R V E D
R E S E R V E D
R E S E R V E D R E S E R V E D
27 W-O R2 2 D- D-
3 GN-W R1 3 C.O.2 TIP C.O.2 TIP STN2 L1 STN2 L1 STN2 L1 STN2 L1 STN2 L1
28 W-GN R2 3 RING RING L2 L2 L2 L2 L2
4 BR-W R1 4
STN2 D+
STN2 D+
R E S E R V E D R E S E R V E D
R E S E R V E D
R E S E R V E D R E S E R V E D
29 W-BR R2 4 D- D-
5 S-W R1 5
C.O.3 TIP STN3 L1 STN3 L1 STN3 L1 STN3 L1 STN3 L1
”
30 W-S R2 5 RING L2 L2 L2 L2 L2
6 BL-R R1 6
STN3 D+
STN3 D+
”
R E S E R V E D
R E S E R V E D
R E S E R V E D R E S E R V E D
31 R-BL R2 6 D- D-
7 O-R R1 7
C.O.4 TIP STN4 L1 STN4 L1 STN4 L1 STN4 L1 STN4 L1
”
32 R-O R2 7 RING L2 L2 L2 L2 L2
8 GR-R R1 8
STN4 D+
STN4 D+
”
R E S E R V E D
R E S E R V E D
R E S E R V E D R E S E R V E D
33 R-GR R2 8 D- D-
9 BR-R R1 9
STN5 L1 STN5 L1
” ”
R E S E R V E D
”
”
34 R-BR R2 9 L2 L2
10 S-R R1 10
STN5 D+
” ” ” ”
R E S E R V E D
”
35 R-S R2 10 D-
11 BL-BK R1 11
STN6 L1 STN6 L1
” ” ” ”
”
36 BK-BL R2 11 L2 L2
12 O-BK R1 12
STN6 D+
” ” ” ”
R E S E R V E D
”
37 BK-O R2 12 D-
13 GR-BK R1 13
STN7 L1 STN7 L1
” ” ” ”
”
38 BK-GR R2 13 L2 L2
14 BR-BK R1 14
STN7 D+
” ” ” ”
R E S E R V E D
”
39 BK-BR R2 14 D-
15 S-BK R1 15
STN8 L1 STN8 L1
” ” ” ”
”
40 BK-S R2 15 L2 L2
16 BL-Y R1 16
STN8 D+
” ” ” ”
R E S E R V E D
”
41 Y-BL R2 16 D-
17 S-Y
X NC NC NC NC NC NC NC
42 Y-S
18 GR-Y
X
” ” ” ” ” ” ”
43 Y-GR
19 BR-Y
X
” ” ” ” ” ” ”
44 Y-BR
20 S-Y
X
” ” ” ” ” ” ”
45 Y-S
21 BL-VL
X
” ” ” ” ” ” ”
46 VL-BL
22 O-VL
X
” ” ” ” ” ” ”
47 VL-O
23 GR-VL
X
” ” ” ” ” ” ”
48 VL-GR
24 BR-VL
X
” ” ” ” ” ” ”
49 VL-BR
25 S-VL
X
” ” ” ” ” ” ”
50 VL-S
FIGURE 4-7 MDFD-C CONNECTIONS(EXPANSION CARD)
2 - 16
2INSTALL 1999.9.15 12:45 PM 페이지22
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
MDF Pin No. Champ Pin No. MDF Pin No. Champ Pin No. MDF Pin No. Champ Pin No.
1 26 21 36 41 46
2 1 22 11 42 21
3 27 23 37 43 47
4 2 24 12 44 22
5 28 25 38 45 48
6 3 26 13 46 23
7 29 27 39 47 49
8 4 28 14 48 24
9 30 29 40 49 50
10 5 30 15 50 25
11 31 31 41 51 RESERVED
12 6 32 16 52 RESERVED
13 32 33 42 53 RESERVED
14 7 34 17 54 RESERVED
15 33 35 43 55 RESERVED
16 8 36 18 56 RESERVED
17 34 37 44 57 RESERVED
18 9 38 19 58 RESERVED
19 35 39 45 59 RESERVED
20 10 40 20 60 RESERVED
FIGURE 4-9 OPTIONAL MDF
2 - 18
2INSTALL 1999.9.15 12:45 PM 페이지24
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
5. CONNECTING TELEPHONE LINES
5.1 SAFETY PRECAUTIONS
To limit the risk of personal injury, always follow these precautions before
connecting to TELCO circuits:
● Never install telephone wiring during a lightning storm.
● Never install telephone jacks in a wet location unless the jack is specifically
designed for wet locations.
● Never touch uninsulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
● Use caution when installing or modifying telephone lines.
5.2 LOOP START LINES
● Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each
loop start C.O. line to the trunk port.
● Refer to FIGURE 4-1 through 4-7 and 4-8.
6. CONNECTING STATION EQUIPMENT
Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each
keyset/AOM or single-line telephone to the keyset port or SLI port of your choice.
6.1 CONNECTING KEYSET / AOM (FIGURE 6-1)
The NX-308 system has seven hybrid ports and the NX-1232 system has eight
hybrid ports.Either a keyset or a single-line telephone may be connected to a
hybrid port. Before connecting station equipment to a hybrid port, the switches on
the Base Board must be set to keyset or SLT.
Each switch is composed of four sections, set to ON/ON/OFF/OFF to connect a
keyset to the hybrid port.
ON
❶ ❷ ❸ ❹
Each numbered switch has four
sections: ❶ ❷ ❸ ❹ .
To connect a keyset to a hybrid port,
they are set to ON/ ON/ OFF/ OFF.
OFF
6.1.1 NX-308 - Related Switch Location (FIGURE 6-3)
To connect a keyset or AOM to station #2 to #8 of basic KSU, the related
DIP switches should be set as follows: (Station #1 is a keyset-only station.)
2 - 20
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
6.2.1 NX-308 - Related Switch Location (FIGURE 6-3)
To connect the single line telephone to the any station from #2 to #8 of basic
KSU, the related DIP switches should be set as follows.
Station No. Releated DIP Switches Setting
❶ ❷ ❸ ❹
STN 2 SW 1 OFF OFF ON ON
STN 3 SW 2 OFF OFF ON ON
STN 4 SW 3 OFF OFF ON ON
S
STN 5 SW 4 OFF OFF ON ON
STN 6 SW 5 OFF OFF ON ON
STN 7 SW 6 OFF OFF ON ON
STN 8 SW 7 OFF OFF ON ON
6.2.2 NX-820
To connect a single-line telephone to the from #5 to #12 of basic KSU.
6.2.3 NX-1232 - Related Switch Location (FIGURE 6-5)
To connect a single line telephone to any station from #1 to #16 of basic KSU.
Station No. Releated DIP Switches Setting
❶ ❷ ❸ ❹
STN 1 SW 8 OFF OFF ON ON
STN 2 SW 7 OFF OFF ON ON
STN 3 SW 6 OFF OFF ON ON
STN 4 SW 5 OFF OFF ON ON
S
STN 5 SW 4 OFF OFF ON ON
STN 6 SW 3 OFF OFF ON ON
STN 7 SW 2 OFF OFF ON ON
STN 8 SW 1 OFF OFF ON ON
2 - 22
2INSTALL 1999.9.15 12:45 PM 페이지26
2INSTALL 1999.9.15 12:45 PM 페이지28
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
Music Source Selection
shunt pin
PFT selection
switch
Hybrid station selection
switches
Memory Back-up
enable shunt pin
Hybrid Station Configuration
KTS : SLT :
FIGURE 6-3 NX-308 KSU SWITCH LOCATIONS
2 - 24
2INSTALL 1999.9.15 12:45 PM 페이지30
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
Music Source Selection
shunt pin
Memory Back-up
enable shunt pin
Hybrid station selection
switches
Hybrid Station Configuration
KTS : SLT :
FIGURE 6-5 NX-1232 KSU SWITCH LOCATIONS
2 - 26
2INSTALL 1999.9.15 12:45 PM 페이지32
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
7.3 DOORPHONE AND DOOR LOCK RELEASE (See FIGURE 7-3)
System users have the capability of communicating with an optional door phone
when the N X - D P H / P A G I N G board is installed. A maximum of two door phones
may be installed per system.
To connect the door phone, plug a two-pair modular cable into the connector on
the KSU marked DOOR1 or DOOR2.
To connect the customer-provided electric door lock unit for control of the door
lock release mechanism, plug a one-pair modular cable into the connector on the
KSU marked LOCKER1 or LOCKER2.
FIGURE 7-3 CONNECTING DOOR PHONE & DOOR LOCK RELEASE
2 - 28
2INSTALL 1999.9.15 12:45 PM 페이지34
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
R-MMC PC
(9 PIN) (9 PIN)
RXD 2 2 RXD
TXD 3 3 TXD
DTR 4 4 DTR
SGND 5 5 SGND
CTS 8
NOTE : If the CTS pin is not connected, the system cannot check the printer
(MODEM) status (power ON/OFF, paper empty, etc.)
FIGURE 7-4 SMDR & REMOTE PROGRAMMING CONNECTIONS
2 - 30
2INSTALL 1999.9.15 12:45 PM 페이지36
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
FIGURE 7-5 CONNECTING EXTERNAL BATTERY
8. BEFORE POWER UP
During initial installation, it is best to verify proper system operation before plugging in
any amphenol-type cables to the MDF. If you have already plugged the cables in,
unplug them. Verify that the AC voltage at the dedicated electric outlet is correct.
Make sure the AC power switch is in the OFF position and memory back-up switch is
ON. Plug the KSU power cord into the dedicated polarized AC outlet. Turn the AC
power switch to the ON position, and verify the status of the "POWER", "MONITOR",
and "IDLE" LEDs on the cover of the KSU. A steady "POWER" LED indicates the
presence of power, and a blinking "MONITOR" LED indicates that the main
processor is functioning. A steady "IDLE" LED indicates that no one is using the
system. If the "POWER" LED fails to illuminate, unplug the system, remove the power
supply, and check the AC fuse located on the bottom.
If the fuse is good but the "POWER" LED does not illuminate, you must correct the
problem before continuing., Turn off the power switch., Unplug all expansion cards
except Base board. Turn the system on. Check the "POWER" LED again. If the
problem is corrected, you have a defective card. Test and remove the faulty card
before continuing.
If the LED still does not light, unplug the KSU and change power supplies or Base
board. This in all probability will solve the problem. If it does not, contact Samsung
Technical Support.
2 - 32
2INSTALL 1999.9.15 12:45 PM 페이지38
NX-SERIESHYBRID KEY SYSTEM INSTALLATION SECTION
9-3 HOW TO REMOVE THE HANDSET CORD FROM THE HANDSET
Driver
Insert the sharp-edged one
(ex:driver, pincette,...) into the
slight gap of handset.
Line holder
Slightly push the driver, and lift
up the line holder from handset.
Now, you have removed the line holder, and can see the modular
jack of the handset cord.
2 - 34