Siemens IC60: Telephone connection

Telephone connection: Siemens IC60

background image

Siemens Building Technologies

Fire Safety & Security Products 

01.2008

t

 the keypad will start beeping to indicate 

that learn mode has been activated. 

2. 

Press the ARM button 

 on the remote 

control 

t

 it will send a transmission signal. The 

panel will confirm if a user is found with 

the message “Found”. 

3. 

Press 

 to confirm. 

4. 

Repeat the actions 1 - 3 to follow up for all  

5 buttons (use the navigation button   to 

switch to the next user number). 

For remote control 2 take user numbers 26 - 

30 etc. 

Telephone connection

To transmit events, the system needs to be  

connected to a telephone line. Follow steps  

8 - 9 to program the telephone numbers. 

If no telephone line is connected, the dialer 

must be turned off: 

1. 

Press 

175

1

t

 the display shows: 

“Dialer A Option 12----7-“. 

2. 

Press 

1

t

 the display shows: “-2----7-“. 

3. 

To check: press 

Ctrl

 simultaneously  

t

  the display changes to clear text mode 

and shows “Enable Dialer No”. 

4. 

Press 

 to go back and continue

with

step 10

“Testing Installation”. 

Telephone numbers

The telephone numbers (max. 8) which are  

dialed in case of an event can be up to  

16 digits long. Default setting: Telephone 

number 8 is the call back number of the  

Control Monitoring Station (CMS). 

1. 

Telephone number 1: 

press 

181

1

“tel.number”

2. 

Choose a reporting format for this number. 

a)

 Number related to a phone:  

press 

182

1

2

  

t

 an alarm signal will be sent out to this 

number when an event occurs. 

b)

 Call goes out to a CMS station: 

CID format: press 

182

1

1

SIA format: press 

182

1

10

3. 

Repeat actions 1 - 2 to follow up for  

telephone numbers 2 - 8 (use the naviga-

tion button   to switch to the next tele-

phone number). 

There are 11 different reporting formats that 

can be selected for each telephone number. 

The formats are listed in the Installer Manual. 

Identification code

When connected to a monitoring station you 

can program an individually identification 

code: 

Area A: press 

62

1

”code”

(4 digit code 0-F). 

Testing Installation

To test the strength of the signal received on 

the panel: press 

200

14

Any time a signal is detected, the keypad 

beeps and displays the received signal 

strength in % for 30 sec. 

To test all detectors on their function and  

transmission range, change to walk test 

mode. 

In the walk test mode the panel will not 

send out any alarms and the working 

range will be less than in the normal op-

erating mode - EN50131 requirement. 

1. 

Start walk test: press 

200

6

t

 the keypad will start beeping to indicate 

that walk test mode has been activated. 

2. 

Activate the installed detectors with a  

magnet  

t

 it will send a transmission signal (for more 

details see Installation Instruction of the 

detector). The panel will give a notification 

signal each time a detector signal is re-

ceived and will show the detector number 

on the display. 

3. 

To end this mode: press 

.  

t

 this will take you back to the normal mode. 

4. 

To check out all received signals in event 

log: press

5. 

To clear events in the log: press 

 or  

enter the installer code (see User Manual 

3.15.3). 

The programming is finished now and the  

system ready to operate.  

Don’t forget to reconnect the internal siren!