LG ARNU76GB8Z2: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру LG ARNU76GB8Z2

ČEŠTINA
ENGLISH
LIMBA ROMÂNĂ
ITALIANO
БЪЛГАРСKN
ESPAÑOL
FRANÇAIS
SRPSKI HRVATSKI
DEUTSCH
SVENDKA
ΕΛΛΗΝΙΚΆ
РУССКИЙ ЯЗЫК
PORTUGUESE
OWNER’S MANUAL
AIR CONDITIONER
NEDERLANDS
Please read this manual carefully before operating
your set and retain it for future reference.
POLSKI
TYPE: Multi V FRESH AIR INTAKE UNIT
MAGYAR
www.lg.com
P/NO : MFL67605115

Fresh Air Intake Unit Ownerʼs Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Safety Precautions.................3
Model #
Prior to Operation ..................6
Serial #
You can find them on a label on the side of each unit.
Operating Instructions...........7
Dealer's Name
Name and Function of Remote
Date Purchased
Controller ..............................7
n Staple your receipt to this page in the event you need
to prove date of purchase or to issue warranty.
Operation Details ...................9
READ THIS MANUAL
Operation Range ..................9
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
Maintenance and Service ....10
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Before you Call for
Troubleshooting Tips first, you may not need to call
Service................................12
for service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Fresh Air Intake Unit

Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
Ownerʼs Manual 3
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
n Installation
Do not use a defective or
For electrical work, contact the
Always ground the product.
underrated circuit breaker. Use
dealer, seller, a qualified
this appliance on a dedicated
electrician, or an Authorized
circuit.
Service Center.
• There is risk of fire or electric
• Do not disassemble or repair the
• There is risk of fire or electric
shock.
product. There is risk of fire or
shock.
electric shock.
Install the panel and the cover
Always install a dedicated
Use the correctly rated breaker
of control box securely.
circuit and breaker.
or fuse.
• There is risk of fire or electric
• Improper wiring or installation
• There is risk of fire or electric
shock.
may cause fire or electric shock
shock.
Do not modify or extend the
Do not install, remove, or re-
Be cautious when unpacking
power cable.
install the unit by yourself
and installing the product.
(customer).
• There is risk of fire or electric
• There is risk of fire, electric shock,
• Sharp edges could cause injury.
shock.
explosion, or injury.
Be especially careful of the case
edges and the fins on the
condenser and evaporator.
For installation, always contact
Do not install the product on a
Be sure the installation area
the dealer or an Authorized
defective installation stand.
does not deteriorate with age.
Service Center.
• There is risk of fire, electric shock,
• It may cause injury, accident, or
• If the base collapses, the air
explosion, or injury.
damage to the product.
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.

Safety Precautions
n Operation
Do not let the air conditioner
Take care to ensure that power
Do not place anything on the
run for a long time when the
cable could not be pulled out or
power cable.
humidity is very high and a
damaged during operation.
door or a window is left open.
• Moisture may condense and wet
• There is risk of fire or electric
• There is risk of fire or electric
or damage furniture.
shock.
shock.
Do not plug or unplug the
Do not touch(operate) the
Do not place a heater or other
power supply plug during
product with wet hands.
appliances near the power
operation.
cable.
• There is risk of fire or electric
• There is risk of fire or electrical
• There is risk of fire and electric
shock.
shock.
shock.
Do not allow water to run into
Do not store or use flammable
Do not use the product in a
electric parts.
gas or combustibles near the
tightly closed space for a long
product.
time.
• It may cause There is risk of fire,
• There is risk of fire or failure of
• Oxygen deficiency could occur.
failure of the product, or electric
product.
shock.
When flammable gas leaks,
If strange sounds, or small or
Stop operation and close the
turn off the gas and open a
smoke comes from product.
window in storm or hurricane.
window for ventilation before
Turn the breaker off or
If possible, remove the product
turn the product on.
disconnect the power supply
from the window before the
cable.
hurricane arrives.
• Do not use the telephone or turn
• There is risk of electric shock or
• There is risk of property damage,
switches on or off.
fire.
failure of product, or electric
There is risk of explosion or fire
shock.
Do not open the inlet grill of the
When the product is soaked
Be cautious that water could
product during operation.
(flooded or submerged),
not enter the product.
(Do not touch the electrostatic
contact an Authorized Service
filter, if the unit is so equipped.)
Center.
• There is risk of physical injury,
• There is risk of fire or electric
• There is risk of fire, electric shock,
electric shock, or product failure.
shock.
or product damage.
Ventilate the product from time to time when
Turn the main power off when cleaning or
operating it together with a stove, etc.
maintaining the product.
• There is risk of fire or electric shock.
• There is risk of electric shock.
When the product is not be used for a long time,
Take care to ensure that nobody could step on or
disconnect the power supply plug or turn off the
fall onto the outdoor unit.
breaker.
• There is risk of product damage or failure, or
• This could result in personal injury and product
unintended operation.
damage.
4 Fresh Air Intake Unit

Safety Precautions
ENGLISH
n Installation
Ownerʼs Manual 5
CAUTION
Always check for gas (refrigerant)
Install the drain hose to ensure
Keep level even when installing
leakage after installation or repair
that water is drained away
the product.
of product.
properly.
• Low refrigerant levels may
• A bad connection may cause
• To avoid vibration or water
cause failure of product.
water leakage.
leakage.
Do not install the product where the noise
Use two or more people to lift and
Do not install the product where
or hot air from the outdoor unit could
transport the product.
it will be exposed to sea wind
damage the neighborhoods.
(salt spray) directly.
• It may cause a problem for your
• Avoid personal injury.
•
It may cause corrosion on the product.
neighbors.
Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation
.
n Operation
Do not expose the skin directly
Do not use the product for special
Do not block the inlet or outlet
to cool air for long periods of
purposes, such as preserving foods,
of air flow.
time. (Don't sit in the draft.)
works of art, etc. It is a consumer air
conditioner, not a precision
refrigeration system.
• This could harm to your health.
• There is risk of damage or loss
• It may cause product failure.
of property.
Use a soft cloth to clean. Do
Do not touch the metal parts of the
Do not step on or put anyting
not use harsh detergents,
product when removing the air
on the product. (outdoor units)
solvents, etc.
filter. They are very sharp!
• There is risk of fire, electric
• There is risk of personal injury.
• There is risk of personal injury
shock, or damage to the plastic
and failure of product.
parts of the product.
Always insert the filter securely.
Do not insert hands or other objects
Do not drink the water drained
Clean the filter every two weeks
through the air inlet or outlet while the
from the product.
or more often if necessary.
product is operated.
• A dirty filter reduces the efficiency of
• There are sharp and moving parts
• It is not sanitary and could cause
the air conditioner and could cause
that could cause personal injury.
serious health issues.
product malfunction or damage.
Use a firm stool or ladder when
Replace the all batteries in the
Do not recharge or
cleaning or maintaining the
remote control with new ones of
disassemble the batteries.
product.
the same type. Do not mix old and
Do not dispose of batteries in a
new batteries or different types of
fire.
batteries.
• Be careful and avoid personal
• There is risk of fire or explosion
• They may burn or explode.
injury.
If the liquid from the batteries gets onto your skin
If you eat the liquid from the batteries, brush your
or clothes, wash it well with clean water. Do not
teeth and see doctor. Do not use the remote if the
use the remote if the batteries have leaked.
batteries have leaked.
• The chemicals in batteries could cause burns or
• The chemicals in batteries could cause burns or
other health hazards.
other health hazards.

Prior to Operation
Prior to Operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision
devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unitʼs power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
6 Fresh Air Intake Unit

Operating Instructions
ENGLISH
Ownerʼs Manual 7
1
10
9
2
8
3
7
4
11
12
5
13
6
14
15
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
Operating Instructions
Name and function of wired remote controller(Accessory)
1. Operation indication screen
2. Set temperature button
•
It will set not room temperature but outlet air temperature.
3. Fan speed button
• Fan Speed have 3 Steps.
• Middle and Low step is same
4. ON/OFF button
5. Opration mode selection button
6. Wireless remote controller receiver
• Some products don't receive the wireless signals.
7. Air flow button
8. Subfunction button
9. Function setting button
10. Ventilation button
11. Reservation
12. Up,down,left,right button
• To check the indoor temperature, press button.
13. Room temperature button
• Displays only the room temperature of the remote
controller perception.
• There is no control of room temperature.
• In case of fresh air intake unit, displays only the
temperature around remote controller.
14. Setting/Cancel button
15. Exit button
※ Some functions may not be operated and displayed depending on the product type.
※ It will display strange value to the room temperature if wired remote controller is not connected.
Model : PQRCVSL0 (Black Color)
PQRCVSL0QW (White Color)

Operating Instructions
Name and function of wired remote controller(Accessory)
8 Fresh Air Intake Unit
8
1
9
2
10
11
3
12
4
13
14
5
6
15
7
16
PQWRCDF0 (Cooling only)
PQWRHDF0 (Heat pump)
Operation Mode
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
•
Cooling Model( ), Heat Pump Model( )
1. Plasma button (optional)
Used to start or stop the plasma-purification
function.
2. Jet cool button
Speed cooling operates super high fan speed.
3. Operation mode selection button
Used to select the operation mode.
4. Function setting button
Used to set or clear auto clean or smart clean.
5. LCD luminosity button (optional)
Used to adjust LCD luminosity
6. Smart clean button (optional)
Used to start or stop smart clean.
7. Clear all button
Used to clear all timer.
8. Room temperature setting button
Used to select the setting outlet temperature
9. ON/OFF button
Used to turn off/on the unit.
10. Indoor fan speed selection button
Fan speed in all step is same
11. Auto swing button
Used to stop or start louver movement and set the
desired up/down airflow direction.
12. Horizontal airflow direction control button
(optional)
Used to set the desired horizontal airflow direction.
13. Timer and time setting button
Used to set the time of starting or stopping and
sleeping operation.
14. Room temperature checking button
• Used to check the room temperature.
• Displays only the room temperature of the remote
controller perception.
There is no control of room temperature.
15. ˚C/˚F switch button
Used to switch temperature reading from Celsius to
Fahrenheit.
16. Reset button
Used to reset the remote controller.

Operation Details
ENGLISH
Operation Details
Operation range
FAU will operate in the below range. Hot outdoor temperature (over 43℃) or cold outdoor temperature (under -
5℃) will make customer feel uncomfortable because FAU outlet temperature might be not enough controlled in
that region. * FAU : Fresh Air Intake Unit
Usage Limitations
Ownerʼs Manual 9
Outdoor Air Temperature (Toa) ℃
43℃ (1)19°C15°C5°C-5°C
Cooling mode
Fan operation (thermo off)
Cooling
Cooling
Fan operation
Fan stop
6°C 18°C
Heating mode
Heating
Fan operation (thermo off)
Fan operation
Heating
16°C
Automatic mode
Heating
Cooling
Cooling
Heating
18°C
16°C
(1)Normal model : 43°C
Tropical model : 48°C
-5°C 19°C 43℃ (2)(33.5°)15°C
(2)Normal model : 43°C
Tropical model : 48°C

Maintenance and Service
Grille, Case, and Remote Controller
o Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
Power supply must be disconnected before
cleaning the indoor unit.
10 Fresh Air Intake Unit
NOTICE
CAUTION: Before performing any maintenance, turn off the main power to
the system.
1. Remove the Air filter.
n
Take hold of the tab and pull slightly forward
Air filter
to remove the filter.
The air filters behind the front grille should be checked and
cleaned once every 2 weeks or more often if neccessary.
CAUTION:
When the air filter is
to be removed, do not touch the
metal parts of the indoor unit.
It may cause an injury.
2. Clean dirt from the air filter using a vacuum
cleaner or washing with water.
n
If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
n
If hot water (50°C or more) is used, it may
n Never use any of the followings:
be deformed.
• Water hotter than 40°C.
Could cause deformation
3. After washing with water, dry well in
and/or discoloration.
the shade.
• Volatile substances.
n
Do not expose the air filter to direct
Could damage the
sunlight or heat from a fire when drying it.
surfaces of the air
conditioner.
4. Install the air filter.
Air outlet vent
Air filter
S
I
N
N
E
R
Maintenance and Service

Maintenance and Service
ENGLISH
When the air conditioner is not going to be used for a long time.
When it is not going to be used for
When the air conditioner is used again.
a long time.
Operate the air conditioner at the
Clean the air filter and install it in the
following settings for 2 to 3 hours.
indoor unit.
• Type of operation: Fan operation mode.
• This will dry out the internal mechanisms.
Turn off the breaker.
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Turn off the breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Check that the ground wire is
connected correctly. It may be
connected to the indoor unit side.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the electricity
used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room.
Keep blinds or curtains
Keep the room temperature
closed.
uniform.
This is not good for the health
Do not let direct sunshine
Adjust the vertical and
and wastes electricity.
enter the room when the air
horizontal airflow direction to
conditioner is in operation.
ensure a uniform temperature
in the room.
Make sure that the doors
Clean the air filter regularly.
Ventilate the room
and windows are shut tight.
occasionally.
Avoid opening doors and
Blockages in the air filter
Since windows are kept
windows as much as possible
reduce the airflow and lower
closed, it is a good idea to
to keep the cool air in the
cooling and dehumidifying
open them and ventilate the
room.
effects. Clean at least once
room now and then.
every two weeks.
Ownerʼs Manual 11

Maintenance and Service
Before you call for service...
12 Fresh Air Intake Unit
?
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persists,
please contact your dealer.
The air conditioner
The room has a
It seems that
Air conditioner does
does not operate.
peculiar odor.
condensation is
not operate for about
leaking from the air
3 minutes when
conditioner.
restart.
• Have you made a
• Check that this is not
• Condensation occurs
• This is the protector
mistake in timer
a damp smell exuded
when the airflow from
of the mechanism.
operation?
by the walls, carpet,
the air conditioner
• Wait about three
• Has the fuse blown
furniture or cloth
cools the warm room
minutes and
or has the circuit
items in the room.
air.
operation will begin.
breaker been
tripped?
Does not cool or heat
The air conditioner
Crack sound is
Remote control
effectively.
operation is noisy.
heard.
display is faint, or no
display at all.
• Is the air filter dirty?
• For a noise that
• This sound is generated
• Are the batteries
See air filter cleaning
sounds like water
by the expansion/
depleted?
instructions.
flowing.
constriction of the front
• Are the batteries
• The room may have
-This is the sound of
panel, etc. due to
inserted in the
been very hot when
freon flowing inside
changes of
opposite (+) and (-)
the room air
the air conditioner
temperature.
directions?
conditioner was first
unit.
turned on. Allow time
• For a noise that
for it to cool down.
sounds like the
• Has the temperature
compressed air
been set incorrectly?
releasing into
• Are the indoor unit's
atmosphere.
air inlet or outlet vents
-This is the sound of
• Cleaning the filter,
obstructed?
the dehumidifying
press the Timer button
water being
and ◀ button of wired
processed inside the
remote controller at
air conditioning unit.
the same time for 3
sec.
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to
excess water.
NOTICE
Filter sign lamp
(LED) is ON.