LG ARNU07GQAA2: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру LG ARNU07GQAA2

ČEŠTINA
ENGLISH ITALIANO
LIMBA ROMÂNĂ
БЪЛГАРСKN
ESPAÑOL
FRANÇAIS
SRPSKI HRVATSKI
DEUTSCH
SVENDKA
ΕΛΛΗΝΙΚΆ
РУССКИЙ ЯЗЫК
PORTUGUESE
OWNER’S MANUAL
AIR CONDITIONER
ҚAЗАҚ TIЛI
NEDERLANDS
Please read this manual carefully before operating
your set and retain it for future reference.
POLSKI
TYPE : CONSOLE
MAGYAR
www.lg.com
P/NO : MFL67605114

Console
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Safety Precautions.................3
Model #
Serial #
You can find them on a label on the side of each unit.
Prior to Operation ..................7
Dealer's Name
Date Purchased
n Staple your receipt to this page in the event you need
Operating Instructions...........8
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Maintenance and Service ....11
Inside you will find many helpful hints on how to use and
Before you Call for Service
maintain your air conditioner properly. Just a little pre-
............................................13
ventive care on your part can save you a great deal of
time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young chil-
dren or invalids without supervision.
• Young children should be supervised to ensure that they
do not play with the air conditioner.
• When the power cord is to be replaced, replacement work
shall be performed by authorized personnel only using
only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Indoor Unit

Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
Ownerʼs Manual 3
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
ENGLISH
n Installation
Do not use a defective or
For electrical work, contact
Always ground the product.
underrated circuit breaker.
the dealer, seller, a qualified
Use this appliance on a ded-
electrician, or an Authorized
icated circuit.
Service Center.
• There is risk of fire or electric
• Do not disassemble or repair
• There is risk of fire or electric
shock.
the product. There is risk of fire
shock.
or electric shock.
Install the panel and the
Always install a dedicated
Use the correctly rated
cover of control box se-
circuit and breaker.
breaker or fuse.
curely.
• There is risk of fire or electric
• Improper wiring or installation
• There is risk of fire or electric
shock.
may cause fire or electric shock
shock.
Do not modify or extend the
Do not install, remove, or
Be cautious when unpack-
power cable.
re-install the unit by your-
ing and installing the prod-
self (customer).
uct.
• There is risk of fire or electric
• There is risk of fire, electric
• Sharp edges could cause injury.
shock.
shock, explosion, or injury.
Be especially careful of the
case edges and the fins on the
condenser and evaporator.
For installation, always contact
Do not install the product on
Be sure the installation area
the dealer or an Authorized
a defective installation stand.
does not deteriorate with age.
Service Center.
• There is risk of fire, electric
• It may cause injury, accident, or
• If the base collapses, the air
shock, explosion, or injury.
damage to the product.
conditioner could fall with it,
causing property damage, prod-
uct failure, and personal injury.

Safety Precautions
n Operation
Do not let the air conditioner run for a
Take care to ensure that power
Do not place anything on
long time when the humidity is very high
cable could not be pulled out
the power cable.
and a door or a window is left open
.
or damaged during operation.
• Moisture may condense and
• There is risk of fire or electric
• There is risk of fire or electric
wet or damage furniture.
shock.
shock.
Do not plug or unplug the
Do not touch(operate) the
Do not place a heater or
power supply plug during
product with wet hands.
other appliances near the
operation.
power cable.
• There is risk of fire or electric
• There is risk of fire or electrical
• There is risk of fire and electric
shock.
shock.
shock.
Do not allow water to run
Do not store or use flammable
Do not use the product in a
into electric parts.
gas or combustibles near the
tightly closed space for a
product.
long time.
• It may cause There is risk of
• There is risk of fire or failure of
• Oxygen deficiency could occur.
fire, failure of the product, or
product.
electric shock.
When flammable gas leaks,
If strange sounds, or small or
Stop operation and close the window
turn off the gas and open a
smoke comes from product. Turn
in storm or hurricane. If possible, re-
window for ventilation be-
the breaker off or disconnect the
move the product from the window
fore turn the product on.
power supply cable.
before the hurricane arrives.
• Do not use the telephone or
• There is risk of electric shock or
• There is risk of property dam-
turn switches on or off.
fire.
age, failure of product, or elec-
There is risk of explosion or fire
tric shock.
Do not open the inlet grill of the
When the product is soaked
Be cautious that water
product during operation.
(flooded or submerged),
could not enter the product.
(Do not touch the electrostatic
contact an Authorized Serv-
filter, if the unit is so equipped.)
ice Center.
• There is risk of physical injury,
• There is risk of fire or electric
• There is risk of fire, electric
electric shock, or product fail-
shock.
shock, or product damage.
ure.
Ventilate the product from time to time
Turn the main power off when cleaning or
when operating it together with a stove, etc.
maintaining the product.
• There is risk of fire or electric shock.
• There is risk of electric shock.
When the product is not be used for a long
Take care to ensure that nobody could step
time, disconnect the power supply plug or
on or fall onto the outdoor unit.
turn off the breaker.
• There is risk of product damage or failure, or unin-
• This could result in personal injury and product
tended operation.
damage.
4 Indoor Unit

Safety Precautions
n Installation
Ownerʼs Manual 5
CAUTION
ENGLISH
Always check for gas (refriger-
Install the drain hose to ensure
Keep level even when in-
ant) leakage after installation or
that water is drained away
stalling the product.
repair of product.
properly.
• Low refrigerant levels may
• A bad connection may cause
• To avoid vibration or water leak-
cause failure of product.
water leakage.
age.
Do not install the product where the
Use two or more people to lift
Do not install the product
noise or hot air from the outdoor unit
and transport the product.
where it will be exposed to
could damage the neighborhoods.
sea wind (salt spray) directly.
• It may cause a problem for your
• Avoid personal injury.
•
It may cause corrosion on the prod-
neighbors.
uct. Corrosion, particularly on the
condenser and evaporator fins,
could cause product malfunction or
inefficient operation
.
n Operation
Do not expose the skin di-
Do not use the product for special
Do not block the inlet or
rectly to cool air for long pe-
purposes, such as preserving
outlet of air flow.
riods of time.
foods, works of art, etc. It is a
(Don't sit in the draft.)
consumer air conditioner, not a
precision refrigeration system.
• This could harm to your health.
• There is risk of damage or loss
• It may cause product failure.
of property.
Use a soft cloth to clean. Do
Do not touch the metal parts of
Do not step on or put anyt-
not use harsh detergents,
the product when removing the
ing on the product. (outdoor
solvents, etc.
air filter. They are very sharp!
units)
• There is risk of fire, electric
• There is risk of personal injury.
• There is risk of personal injury
shock, or damage to the plastic
and failure of product.
parts of the product.
Always insert the filter se-
Do not insert hands or other
Do not drink the water
curely. Clean the filter every
objects through the air inlet
drained from the product.
two weeks or more often if
or outlet while the product
necessary.
is operated.
• A dirty filter reduces the efficiency
• There are sharp and moving parts
• It is not sanitary and could cause
of the air conditioner and could
that could cause personal injury.
serious health issues.
cause product malfunction or
damage. (Grill Type)

Safety Precautions
Use a firm stool or ladder
Replace the all batteries in the
Do not recharge or disas-
when cleaning or maintain-
remote control with new ones
semble the batteries. Do not
ing the product.
of the same type. Do not mix
dispose of batteries in a
old and new batteries or differ-
fire.
ent types of batteries.
• Be careful and avoid personal
• There is risk of fire or explosion
• They may burn or explode.
injury.
If the liquid from the batteries gets onto
If you eat the liquid from the batteries,
your skin or clothes, wash it well with clean
brush your teeth and see doctor. Do not use
water. Do not use the remote if the batteries
the remote if the batteries have leaked.
have leaked.
• The chemicals in batteries could cause burns or
• The chemicals in batteries could cause burns or
other health hazards.
other health hazards.
6 Indoor Unit

Prior to operation
ENGLISH
Prior to Operation
Preparing for Operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision de-
vices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and Maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unitʼs power is acciden-
tally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
Ownerʼs Manual 7

Operating Instructions
Operating Instructions
Name and Function of Wired Remote Controller(Accessory)
8 Indoor Unit
1
10
9
2
8
3
7
4
11
12
5
13
6
14
15
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
PQRCVSLO
1. Operation indication screen
2. Set temperature button
3. Fan speed button
4. ON/OFF button
5. Opration mode selection button
6. Wireless remote controller receiver
• Some products don't receive the wireless
signals.
7. Air flow button
8. Subfunction button
9. Function setting button
10. Ventilation button
11. Reservation
12. Up,down,left,right button
• To check the indoor temperature,
press button.
13. Room temperature button
14. Setting/Cancel button
15. Exit button
h Some functions may not be operated and displayed depending on the product type.

Operating Instructions
Name and Function of Wireless Remote Controller(Accessory)
Ownerʼs Manual 9
8
1
9
2
10
11
3
12
4
13
14
5
6
15
7
16
PQWRCDF0 (Heat pump)
PQWRHDF0 (Cooling only)
Operation Mode
Cooling mode
Auto mode or auto changeover
Dehumidification mode
Heating mode
Fan mode
•
Cooling model( ), Heat pump model( )
ENGLISH
1. Plasma button (Optional).
Used to start or stop the Ion generator.
2. Jet cool button
Speed cooling operates super high fan speed.
3. Operation mode selection button
Used to select the operation mode.
4. Used to set auto clean, smart clean, floor
heating and Upper vane control on respec-
tive key stroke.
5. Used to adjust LCD luminosity also for ad-
th
justing the upper vane angle followed by 4
number key
6. Smart clean button(optional)
Used to start or stop smart clean.
7. Clean button
Used to clear all timer.
8. Room temperature setting button
Used to select the room temperature.
9. On/Off button
Used to turn on/off the unit.
10. Indoor fan speed selection button
Used to select fan speed in four steps low,
medium, high and chaos.
11. Auto swing button
Used to stop or start louver movement and set
the desired up/down airflow direction.
12. Horizontal airflow direction control
button(optional)
Used to set the desired horizontal airflow direc-
tion.
13. Timer and time setting button
Used to set the time of starting or stopping and
sleeping operation.
14. Room temperature checking button
Used to check the room temperature.
15. °C/°F switch button
Used to switch temperature reading from Cel-
sius to Fahrenheit.
16. Reset button
Used to reset the remote controller.

Operating Instructions
10 Indoor Unit
ON/OFF
button
Forced Operation
Operation procedures when the remote control can't be
used.
Press the tact switch (forced operation) for 2 seconds.
If you want to stop operation, press again the tact switch.
In case the power comes on again after power failure on
the forced operation mode, the operating conditions are
automatically set as follows:
During forced operation, the initial mode continues.
Heat pump model
Cooling model
Room temperature
≥
Room temperature
<
set temperature -2°C
set temperature -2°C
Operating mode Cooling Cooling Heating
Indoor fan Speed High Set available Set available
Setting temperature 22°C Set available Set available
Auto Restart Function
In case the power comes on again after a power failure, auto restarting operation is the function to operate proce-
dures automatically to the previous operating conditions.
Tips for Filter Sign LED (Grille Type)
1. Filter sign lamp (LED) is on.
2. If LED indicating filter sign lamp is on, clean the filter.
3. After cleaning the filter, press the timer button and
◀
button of wired remote controller at the same time for 3 sec-
onds. Then filter sign LED is off.

Maintenance and Service
ENGLISH
Maintenance and Service
CAUTION
Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and
unplug the power cord.
Cleaning of Panel and filters
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.
CAUTION
Never use any of these
• Water hotter than 40°C. It may cause deformation and discoloration.
• Volatile substances. They may damage the surface of the air conditioner.
Air Filters
The air filters behind the front panel / grill should be checked and cleaned once in
every 2 weeks or more often if necessary. To remove the filters see the self explanatory
diagrams below. Clean the filters with a vacuum cleaner or warm soapy water.
If dirt is not easily removed, wash with a solution of detergent in luke warm water.
Dry well in shade after washing and reinstall the filters back in place.
Allergy Filter
Remove the Allergy Filter behind the air filter and expose them in
direct sunlight for 2 hours.
And then insert these filters into original position.
Removal of Grille
1. Open the front grille by pulling forward
2. Then pull out the link of grille from groove in front panel.
3. Then pull out 2 hinges of grille from grooves in front panel.
Removal of Filters
1. Pull down the filter tab slightly to
remove the air filter.
2. Hold the tabs of the frame, and
remove the claws in 4 places.
Ownerʼs Manual 11

Maintenance and Service
12 Indoor Unit
CAUTION
CAUTION
When the air conditioner is not going to be used for a long time.
When it is not going to be used for
When the air conditioner is to be used again.
a long time.
Operate the air conditioner at the follow-
Clean the air filter and install it in the
ing settings for 2 to 3 hours.
indoor unit.
• Type of operation: Fan operation mode.
• This will dry out the internal mechanisms.
Turn off the breaker.
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Turn off the breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Check that the ground wire is con-
nected correctly. It may be connect to
the indoor unit side.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the electricity
used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room. Keep blinds or curtains
Keep the room temperature
closed.
uniform.
This is not good for the health
Do not let direct sunshine
Adjust the vertical and hori-
and wastes electricity.
enter the room when the air
zontal airflow direction to en-
conditioner is in operation.
sure a uniform temperature in
the room.
Make sure that the doors
Clean the air filter regularly. Ventilate the room occasion-
and windows are shut tight.
ally.
Avoid opening doors and
Blockages in the air filter re-
Since windows are kept
windows as much as possible
duce the airflow and lower
closed, it is a good idea to
to keep the cool air in the
cooling and dehumidifying ef-
open them and ventilate the
room.
fects. Clean at least once
room now and then.
every two weeks.

Maintenance and Service
Before you call for service...
Ownerʼs Manual 13
?
ENGLISH
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
The air conditioner
The room has a pe-
It seems that con-
Air conditioner does
does not operate.
culiar odor.
densation is leaking
not operate for about
from the air condi-
3 minutes when
tioner.
restart.
• Have you made a
• Check that this is not
• Condensation occurs
• This is the protector
mistake in timer op-
a damp smell exuded
when the airflow from
of the mechanism.
eration?
by the walls, carpet,
the air conditioner
• Wait about three
• Has the fuse blown
furniture or cloth
cools the warm room
minutes and opera-
or has the circuit
items in the room.
air.
tion will begin.
breaker been
tripped?
Does not cool or heat
The air conditioner
Crack sound is
Remote control dis-
effectively.
operation is noisy.
heard.
play is faint, or no
display at all.
• Is the air filter dirty?
• For a noise that
• This sound is gener-
• Are the batteries de-
See air filter cleaning
sounds like water
ated by the expansion/
pleted?
instructions.
flowing.
constriction of the front
• Are the batteries in-
• The room may have
- This is the sound of
panel, etc. due to
serted in the opposite
been very hot when
freon flowing inside
changes of tempera-
(+) and (-) directions?
the room air condi-
the air conditioner
ture.
tioner was first turned
unit.
on. Allow time for it to
• For a noise that
Filter sign lamp
cool down.
sounds like the com-
(LED) is ON.
• Has the temperature
pressed air releasing
(Grill Type)
been set incorrectly?
into atmosphere.
• Are the indoor unit's
- This is the sound of
air inlet or outlet vents
the dehumidifying
• Cleaning the filter,
obstructed?
water being
press the Timer but-
processed inside the
ton and ◀ button of
air conditioning unit.
wired remote con-
troller at the same
time for 3 sec.
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to ex-
cess water.

14 Indoor Unit