LG ARNU09GB3G2.ENWALEU: инструкция
Раздел: Бытовая, кухонная техника, электроника и оборудование
Тип: Кондиционер
Инструкция к Кондиционеру LG ARNU09GB3G2.ENWALEU

ČEŠTINA
ENGLISH ITALIANO
LIMBA ROMÂNĂ
БЪЛГАРСKN
ESPAÑOL FRANÇAIS
SRPSKI HRVATSKI
DEUTSCH
SVENDKA
ΕΛΛΗΝΙΚΆ
РУССКИЙ ЯЗЫК
PORTUGUESE
OWNER’S MANUAL
NEDERLANDS
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
POLSKI
TYPE : BUILT - IN DUCT - LOW STATIC
MAGYAR
www.lg.com
P/NO : MFL67605108

Ceiling Concealed Duct – Low Static Type Indoor Unit Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Safety Precautions.................3
Model #
Prior to Operation ..................6
Serial #
You can find them on a label on the side of each unit.
Operating Instructions...........7
Dealer's Name
Name and function of wired
Date Purchased
remote controller(Accessory)
...7
■ Staple your receipt to this page in the event you need
to prove date of purchase or to issue warranty.
Maintenance and Service ......9
Before you Call for
READ THIS MANUAL
Service................................11
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Indoor Unit

Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
Owner’s Manual 3
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
■ Installation
Do not use a defective or
For electrical work, contact the
Always ground the product.
underrated circuit breaker. Use
dealer, seller, a qualified
this appliance on a dedicated
electrician, or an Authorized
circuit.
Service Center.
• There is risk of fire or electric
• Do not disassemble or repair the
• There is risk of fire or electric
shock.
product. There is risk of fire or
shock.
electric shock.
Install the panel and the cover
Always install a dedicated
Use the correctly rated breaker
of control box securely.
circuit and breaker.
or fuse.
• There is risk of fire or electric
• Improper wiring or installation
• There is risk of fire or electric
shock.
may cause fire or electric shock
shock.
Do not modify or extend the
Do not install, remove, or re-
Be cautious when unpacking
power cable.
install the unit by yourself
and installing the product.
(customer).
• There is risk of fire or electric
• There is risk of fire, electric shock,
• Sharp edges could cause injury.
shock.
explosion, or injury.
Be especially careful of the case
edges and the fins on the
condenser and evaporator.
For installation, always contact
Do not install the product on a
Be sure the installation area
the dealer or an Authorized
defective installation stand.
does not deteriorate with age.
Service Center.
• There is risk of fire, electric shock,
• It may cause injury, accident, or
• If the base collapses, the air
explosion, or injury.
damage to the product.
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.

Safety Precautions
■ Operation
Do not let the air conditioner
Take care to ensure that power
Do not place anything on the
run for a long time when the
cable could not be pulled out or
power cable.
humidity is very high and a
damaged during operation.
door or a window is left open.
• Moisture may condense and wet
• There is risk of fire or electric
• There is risk of fire or electric
or damage furniture.
shock.
shock.
Do not plug or unplug the
Do not touch(operate) the
Do not place a heater or other
power supply plug during
product with wet hands.
appliances near the power
operation.
cable.
• There is risk of fire or electric
• There is risk of fire or electrical
• There is risk of fire and electric
shock.
shock.
shock.
Do not allow water to run into
Do not store or use flammable
Do not use the product in a
electric parts.
gas or combustibles near the
tightly closed space for a long
product.
time.
• It may cause There is risk of fire,
• There is risk of fire or failure of
• Oxygen deficiency could occur.
failure of the product, or electric
product.
shock.
When flammable gas leaks,
If strange sounds, or small or
Stop operation and close the
turn off the gas and open a
smoke comes from product.
window in storm or hurricane.
window for ventilation before
Turn the breaker off or
If possible, remove the product
turn the product on.
disconnect the power supply
from the window before the
cable.
hurricane arrives.
• Do not use the telephone or turn
• There is risk of electric shock or
• There is risk of property damage,
switches on or off.
fire.
failure of product, or electric
There is risk of explosion or fire
shock.
Do not open the inlet grill of the
When the product is soaked
Be cautious that water could
product during operation.
(flooded or submerged),
not enter the product.
(Do not touch the electrostatic
contact an Authorized Service
filter, if the unit is so equipped.)
Center.
• There is risk of physical injury,
• There is risk of fire or electric
• There is risk of fire, electric shock,
electric shock, or product failure.
shock.
or product damage.
Ventilate the product from time to time when
Turn the main power off when cleaning or
operating it together with a stove, etc.
maintaining the product.
• There is risk of fire or electric shock.
• There is risk of electric shock.
When the product is not be used for a long time,
Take care to ensure that nobody could step on or
disconnect the power supply plug or turn off the
fall onto the outdoor unit.
breaker.
• There is risk of product damage or failure, or
• This could result in personal injury and product
unintended operation.
damage.
4 Indoor Unit

Safety Precautions
ENGLISH
■ Installation
Owner’s Manual 5
CAUTION
Always check for gas (refrigerant) leakage
Install the drain hose to ensure that
Keep level even when installing
after installation or repair of product.
water is drained away properly.
the product.
• Low refrigerant levels may
• A bad connection may cause
• To avoid vibration or water
cause failure of product.
water leakage.
leakage.
Do not install the product where the noise
Use two or more people to lift and
Do not install the product where
or hot air from the outdoor unit could
transport the product.
it will be exposed to sea wind
damage the neighborhoods.
(salt spray) directly.
• It may cause a problem for your
• Avoid personal injury.
•
It may cause corrosion on the product.
neighbors.
Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation
.
■ Operation
Do not expose the skin directly
Do not use the product for special
Do not block the inlet or outlet
to cool air for long periods of
purposes, such as preserving foods,
of air flow.
time. (Don't sit in the draft.)
works of art, etc. It is a consumer air
conditioner, not a precision
refrigeration system.
• This could harm to your health.
•
There is risk of damage or loss of property.
• It may cause product failure.
Use a soft cloth to clean. Do
Do not touch the metal parts of the
Do not step on or put anyting
not use harsh detergents,
product when removing the air
on the product. (outdoor units)
solvents, etc.
filter. They are very sharp!
• There is risk of fire, electric
• There is risk of personal injury.
• There is risk of personal injury
shock, or damage to the plastic
and failure of product.
parts of the product.
Always insert the filter securely.
Do not insert hands or other objects
Do not drink the water drained
Clean the filter every two weeks
through the air inlet or outlet while the
from the product.
or more often if necessary.
product is operated.
• A dirty filter reduces the efficiency of
• There are sharp and moving parts
• It is not sanitary and could cause
the air conditioner and could cause
that could cause personal injury.
serious health issues.
product malfunction or damage.
Use a firm stool or ladder when
Replace the all batteries in the remote
Do not recharge or
cleaning or maintaining the
control with new ones of the same
disassemble the batteries.
product.
type. Do not mix old and new batteries
Do not dispose of batteries in a
or different types of batteries.
fire.
•
Be careful and avoid personal injury.
• There is risk of fire or explosion
• They may burn or explode.
If the liquid from the batteries gets onto your skin
If you eat the liquid from the batteries, brush your
or clothes, wash it well with clean water. Do not
teeth and see doctor. Do not use the remote if the
use the remote if the batteries have leaked.
batteries have leaked.
• The chemicals in batteries could cause burns or
• The chemicals in batteries could cause burns or
other health hazards.
other health hazards.
OPERATING TEMPERATURE(°C)
COOLING MODE
HEATING MODE
INDOOR OUTDOOR
INDOOR OUTDOOR
MAX. MIN. MAX. MIN.
MAX. MIN. MAX. MIN.
32°C
21°
C
43°
C
21°
C
27°C
20°
C
24°
C
1°
C

Prior to operation
Prior to Operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision
devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
6 Indoor Unit

Operating Instructions
Operating Instructions
ENGLISH
Operating Instructions
Name and function of wired remote controller(Accessory)
Owner’s Manual 7
1
10
9
2
8
3
7
4
11
12
5
13
6
14
15
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
1. Operation indication screen
2. Set temperature button
•
It will set not room temperature but outlet air temperature.
3. Fan speed button
• Fan Speed have 3 Steps.
• Middle and Low step is same
4. ON/OFF button
5. Opration mode selection button
6. Wireless remote controller receiver
• Some products don't receive the wireless signals.
7. Air flow button
8. Subfunction button
9. Function setting button
10. Ventilation button
11. Reservation
12. Up,down,left,right button
• To check the indoor temperature, press button.
13. Room temperature button
• Displays only the room temperature of the remote
controller perception.
• There is no control of room temperature.
• In case of fresh air intake unit, displays only the
temperature around remote controller.
14. Setting/Cancel button
15. Exit button
※ Some functions may not be operated and displayed depending on the product type.
※ It will display strange value to the room temperature if wired remote controller is not connected.
Model : PQRCVSL0 (Black Color)
PQRCVSL0QW (White Color)

Operating Instructions
Name and function of wired remote controller(Optional)
8 Indoor Unit
8
1
9
2
10
11
3
12
4
13
14
5
6
15
7
16
PQWRHDF0 (Heat pump)
PQWRCDF0 (Cooling only)
Operation Mode
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
•
Cooling Model( ), Heat Pump Model( )
1. Plasma button (optional)
Used to start or stop the plasma-purification
function.
2. Jet cool button
Speed cooling operates super high fan speed.
3. Operation mode selection button
Used to select the operation mode.
4. Function setting button
Used to set or clear auto clean or smart clean.
5. LCD luminosity button (optional)
Used to adjust LCD luminosity
6. Smart clean button (optional)
Used to start or stop smart clean.
7. Clear all button
Used to clear all timer.
8. Room temperature setting button
Used to select the room temperature.
8. ON/OFF button
Used to turn off/on the unit.
10. Indoor fan speed selection button
Used to select fan speed in four steps low,
medium, high and chaos.
11. Auto swing button
Used to stop or start louver movement and set the
desired up/down airflow direction.
12. Horizontal airflow direction control button
(optional)
Used to set the desired horizontal airflow direction.
13. Timer and time setting button
Used to set the time of starting or stopping and
sleeping operation.
14. Room temperature checking button
Used to check the room temperature.
15. ˚C/˚F switch button
Used to switch temperature reading from celsius to
fahrenheit.
16. Reset button
Used to reset the remote controller.

Maintenance and Service
ENGLISH
Owner’s Manual 9
S
I
N
N
E
R
S
C
O
U
R
I
N
G
B
C
e
n
L
z
e
n
e
B
A
R
G
E
R
Air-Filter
Grille, Case, and Remote Control
❏ Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
Supply power must be disconnected before
cleaning the indoor unit.
NOTICE
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to
the system.
❏
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
• Volatile substances
Could damage the surfaces of the air
conditioner.
Air Filter
The air filters behind Indoor unit
(the suction side) should be checked and cleaned once
every 2 weeks or more often if necessary.
1. Clean the filter with a vacuum or warm, soapy
water.
• If very dirty, wash with a solution of
detergent in lukewarm water.
• If hot water (50°C or more) is used,
filter may be deformed.
2. After washing with water, dry well in the
shade.
3. Re-install the air filter.

Maintenance and Service
When the air conditioner is not going to be used for a long time.
10 Indoor Unit
CAUTION
CAUTION
When the air conditioner is to
When it is not going to be used for
be used again.
a long time.
■ Check that the air inlet and outlet of the
Operate the air conditioner on Air
circulation mode for 2 to 3 hours.
indoor/outdoor unit are not blocked.
• This will dry out the internal parts.
Turn off the circuit breaker.
Helpful information
The air filters and your electiric bill.
Turn off the circuit breaker when the air conditioner
If the air filters become clogged with dust, the
is not going to be used for a long time.
cooling capacity will drop, and 6% of the electricity
Dirt may collect and may cause a fire.
used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room.
Keep blinds or curtains
Make sure that the doors
closed.
and windows are shut tight.
This is not good for the health
Do not let direct sunshine
Avoid opening doors and
and wastes electricity.
enter the room when the air
windows as much as possible
conditioner is in operation.
to keep the cool air in the
room.
Clean the air filter regularly.
Ventilate the room
occasionally.
Blockages in the air filter
Since windows are kept
reduce the airflow and lower
closed, it is a good idea to
cooling and dehumidifying
open them and ventilate the
effects. Clean at least once
room now and then.
every two weeks.

?
Maintenance and Service
ENGLISH
Before you call for service...
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persists,
please contact your dealer.
The air conditioner
The room has a
It seems that
Air conditioner does
does not operate.
peculiar odor.
condensation is
not operate for about
leaking from the air
3 minutes when
conditioner.
restart.
• Have you made a
• Check that this is not
• Condensation occurs
• This is the protector
mistake in timer
a damp smell exuded
when the airflow from
of the mechanism.
operation?
by the walls, carpet,
the air conditioner
• Wait about three
• Has the fuse blown
furniture or cloth
cools the warm room
minutes and
or has the circuit
items in the room.
air.
operation will begin.
breaker been
tripped?
Does not cool or heat
The air conditioner
Crack sound is
Remote control
effectively.
operation is noisy.
heard.
display is faint, or no
display at all.
• Is the air filter dirty?
• For a noise that
• This sound is generated
• Are the batteries
See air filter cleaning
sounds like water
by the expansion/
depleted?
instructions.
flowing.
constriction of the front
• Are the batteries
• The room may have
-This is the sound of
panel, etc. due to
inserted in the
been very hot when
freon flowing inside
changes of
opposite (+) and (-)
the room air
the air conditioner
temperature.
directions?
conditioner was first
unit.
turned on. Allow time
• For a noise that
for it to cool down.
sounds like the
• Has the temperature
compressed air
been set incorrectly?
releasing into
• Are the indoor unit's
atmosphere.
air inlet or outlet vents
-This is the sound of
• Cleaning the filter,
obstructed?
the dehumidifying
press the Timer button
water being
and ◀ button of wired
processed inside the
remote controller at
air conditioning unit.
the same time for 3
sec.
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to
excess water.
Owner’s Manual 11
NOTICE
Filter sign lamp
(LED) is ON.

Memo
12 Indoor Unit