Electrolux EFP60241X: INSTALLATION

INSTALLATION : Electrolux EFP60241X

INSTALLATION

Drilling the Support surface and Fitting the Hood

• The Hood can be fitted directly on the

lower surface of the Wall Units (650 mm

1

min. above the Cooker Top) using the snap-

on Side Supports.

Make an opening on the lower surface of

the Wall Unit, as indicated. (fig.1)

162

Before carrying out the installation, the

523

wooden transportation protections screwed

on the visor and on the canopy body must

be removed. (fig.2)

Choose the correct flange measure basing

on the air outlet diameter and insert it to the

upper air outlet opening. (fig.3)

Screw the closing profile 20 onto the rear

part of the hood, using the screws 12f (2.9

x 9.5) provided. (fig.4)

Open the sliding suction panel.

Remove the metal grease filters one by one

after having disconnected the relative fas-

tening elements.

Close the sliding suction panel again.

Insert the Hood until the snap-on side sup-

ports click into place. (fig.5)

Open the sliding suction panel.

Lock in position by tightening the screws

Vf from underneath the Hood. (fig.5)

If necessary, adjust the whole filter holder

unit and proceed as follows:

Loosen the four adjustment screws Vr

and close the sliding panel again. (fig.6)

Move the entire filter holder unit until it

is properly aligned with the wall unit.

(fig.7)

Keeping the hood canopy still, remove

the sliding panel and lock the adjustment

screws again. (fig.6)

The hood can now be fastened to the

wall unit using the four screws 12a (3.5

x 16) provided. (fig.8)

Replace the metal grease filters.

Close the sliding suction panel again.

6

EN

6

2

10b

10a

9

10a

3

5

Vr

6

7

12a

8

4

Connections

DUCTING VERSION AIR EXHAUST SYSTEM

When installing the hood in ducting version, a rigid or a

flexible pipe with the diameter corresponding to the

flange diameter is used in order to connect the hood to

the air outlet piping.

• Fix the pipe with an adequate quantity of pipe

clamps (not supplied).

Remove possible charcoal filters.

RECIRCULATION VERSION AIR OUTLET

12e

Cut a hole ø 125 mm in any shelf that may be posi-

8

tioned over the hood.

Insert the flange 10a on the hood body outlet.

Connect the flange to the outlet on the shelf over the

hood using a flexible or rigid pipe ø120 mm.

Fix the pipe in position using sufficient pipe clamps

(not supplied).

Fix the directional grille 8 on the recirculation air

outlet using the 2 screws 12e (2,9 x 12,7) provided.

Ensure that the activated charcoal filters have been

inserted.

ELECTRICAL CONNECTION

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3

mm..

7

EN

7