Indesit K6 C51/R: Installation Instructions

Installation Instructions: Indesit K6 C51/R

Installation Instructions

The following instructions should be read by a qualified

To install the cable, proceed as follows:

technician to ensure that the appliance is installed,

unscrew the wire clamp screw and the contact screws

regulated and technically serviced correctly in compliance

Note: the jumpers are factory-set for a single-phase

with current regulations.

230V connection (Fig. A).

Important: The power supply to the appliance must be

to make the electrical connections illustrated in fig. C

cut off before any adjustments or maintenance work is

and fig. D, use the two jumpers housed in the box (fig.

done on it.

B - reference P”)

fasten the supply cable in place with the clamp and

Positioning

close the cover of the terminal board.

The cooker is manufactured with type X degree protection

against overheating.

230V 1N~

H07RN-F 3x4 CEI-UNEL 35364

Levelling Your Appliance (only on certain models)

4 support feet which are adjusted using screws are located

NL

in the lower part of the cooker. These level off the oven

when necessary. It is essential that the cooker be standing

5

3

1

level.

4

2

Fig. A

Mounting the legs (only on certain models)

Press-fit legs are supplied which fit under the base of your

cooker.

Fitting on a Power Supply Cable

Opening the terminal board:

Using a screwdriver, prise on the side tabs of the

terminal board cover;

Pull open the cover of the terminal board.

26

P

N

L3

L2

L1

Fig. B

400V 2N~

H05RR-F 4x2.5 CEI-UNEL 35363

NL2L1

5

3

1

4

2

Fig. C

400V 3N~

H05RR-F 5x2.5 CEI-UNEL 35363

NL3L1L2

5

3

1

4

2

Fig. D

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load

indicated on the data plate. When connecting the cable

directly to the mains, install an omnipolar circuit-breaker

with a minimum contact opening of 3 mm between the

appliance and the mains. The omnipolar circuit breaker

should be sized according to the load and should comply

with current regulations (the green-yellow earth wire should

not be interrupted by the circuit breaker). The supply cable

should be positioned so that it does not reach a tempera-