Indesit KJ1G1: Burner and nozzle characteristics

Burner and nozzle characteristics: Indesit KJ1G1

background image

17

remove the knob and adjust the regulation screw, which

is positioned in or next to the tap pin, until the flame is

small but steady.

N.B.:

 in the case of liquid gas, the regulation screw

must be screwed in to the bottom.

check that the flame does not turn off when you turn

the tap quickly from high to low.

d

Regulating the primary air of the burners:

The primary air of the burners requires no regulation.

Important

On completion of the operation, replace the old rating

sticker with one indicating the new type of gas used. This

sticker is available from our Service Centres.

Note

Should the pressure of the gas used be different (or vary)

from the recommended pressure, it is necessary to fit a

suitable pressure regulator onto the inlet pipe in

compliance with current National Regulations relative to

“regulators for channelled gas”.

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

Burner and nozzle characteristics

S S

R

A

KJ1G1/R

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nozzle

1/100

Flow*

l/h

Nominal Reduced

(mm)

(mm)

***

**

(mm)

(mm)

Fast

(Large)(R)

100

3.00

0.7

41

87

218

214

128

286

143

286

Semi Fast

(Medium)(S)

75

1.90

0.4

30

70

138

136

104

181

118

181

Auxiliary

(Small)(A)

51

1.00

0.4

30

52

73

71

76

95

80

95

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20

35

37

25

45

20

17

25

13

6,5

18