Indesit K6G52S/R: Burner and Nozzle Specifications

Burner and Nozzle Specifications: Indesit K6G52S/R

c) Minimum regulation of the hob burners:

Important

Turn the tap to minimum;

On completion of this operation, replace the old rating

Remove the knob and adjust the regulation screw,

sticker with one indicating the new type of gas used. This

which is positioned in or next to the tap pin, until the

sticker is available from our Service Centres.

flame is small but steady.

Note

NB.: In the case of liquid gas, the regulation screw

Should the pressure of the gas used be different (or vary)

must be screwed in all the way.

from the recommended pressure, it is necessary to fit a

Check that the flame does not go out when you turn

suitable pressure regulator onto the inlet pipe in compli-

the tap quickly from high to low.

ance with current standards regarding “regulators for chan-

d) Regulating the primary air of the burners: the primary

nelled gas..

air of the burners does not need to be regulated.

Burner and Nozzle Specifications

Table 1 Liquid Gas Natural Gas

Burner Diameter

Thermal Power

By-Pass

Nozzle

Flow*

Nozzle

Flow*

Nozzle

Flow*

(mm)

kW (p.c.s.*)

1/100

1/100

g/h

1/100

l/h

1/100

l/h

Nominal Reduced (mm) (mm) *** ** (mm) (mm)

Fast

100 3.00 0.7 41 86 218 214 116 286 143 286

(Large)(R)

Semi Fast

75 1.90 0.4 30 70 138 136 106 181 118 181

(Medium)(S)

Auxiliary

55 1.00 0.4 30 50 73 71 79 95 80 95

(Small)(A)

Nominal (mbar)

28-30

37

20

13

Supply

Minimum (mbar)

20

25

17

6,5

Pressures

Maximum (mbar)

35

45

25

18

* At 15°C and 1013 mbar- dry gas

** Propane P.C.S. = 50,37 MJ/Kg

*** Butane P.C.S. = 49,47 MJ/Kg

3

Natural P.C.S. = 37,78 MJ/m

S

S

R

A

K6 G52S/R

17