! It is important to conserve this booklet for consultation at any moment. In

AIR VENT

the case of sale, cession or move, make sure it is together with the product.

EN

(for the suction versions)

! Read the instructions carefully: there is important information about

Connect the hood and discharge holes on the walls with a diameter equivalent to

installation, use and safety.

the air outlet (connection flange).

! Do not carry out electrical or mechanical variations on the product or on the

Using the tubes and discharge holes on walls with smaller dimensions will cause

discharge conduits.

a diminution of the suction performance and a drastic increase in noise.

GENERAL SAFETY

Any responsibility in the matter is therefore declined.

The minimum distance between the supporting surface for the cooking

! Use a duct of the minimum indispensible length.

equipment on the hob and the lowest part of the range hood must be not less

! Use a duct with as few elbows as possible (maximum elbow angle: 90°).

than 60cm from electric cookers and 70cm from gas or mixed cookers.

! Avoid drastic changes in the duct cross-section.

If the instructions for installation for the gas hob specify a greater distance, this

! Use a duct with an as smooth as possible inside.

must be adhered to.

! The duct must be made of certified material.

Expansion wall plugs are provided to secure the hood to most types of

! The company declines any responsibility whenever these regulations are

walls/ceilings. However, a qualified technician must verify suitability of the

not respected.

materials in accordance with the type of wall/ceiling. The wall/ceiling must be

FILTERING OR DUCTING ?

strong enough to take the weight of the hood. Do not tile, grout or silicone this

! Your cooker hood is ready to be used in suction version.

appliance to the wall. Surface mounting only.

To use the hood in filtering version the special ACCESSORY KIT must be

WARNING! Do not connect the appliance to the mains until the installation is

installed.

fully complete.

Check on the first pages of this manual if the ACCESSORY KIT is furnished

Before any cleaning or maintenance operation, disconnect hood from the mains

or must be bought separately.

by removing the plug or disconnecting the mains electrical supply.

Note: If furnished, in certain cases, the additional activated carbon filtering

Always wear work gloves for all installation and maintenance operations.

system may be installed on the hood.

The appliance is not intended for use by children or persons with impaired

Information about the conversion of the hood from suction version to filtering

physical, sensorial or mental faculties, or if lacking in experience or know-how,

version is present in this manual.

unless they are under supervision or have been trained in the use of the

appliance by a person responsible for their safety.

Ducting version

Children should be monitored to ensure that they do not play with the appliance.

In this case the fumes are conveyed outside by means of a special pipe

This appliance is designed to be operated by adults. Children should not be

connected with the connection ring located on top of the hood.

allowed to tamper with the controls or play with the appliance.Never use the

Attention! The exhausting pipe is not supplied and must be purchased apart.

hood without effectively mounted grating!

Diameter of the exhausting pipe must be equal to that of the connection ring =

The hood must NEVER be used as a support surface unless specifically

150mm.

indicated.

In the horizontal runs the exhausting pipe must be slightly slanted (about 10°)

The premises where the appliance is installed must be sufficiently ventilated,

and directed upwards to vent the air easily from the room to the outside.

when the kitchen hood is used together with other gas combustion devices or

Attention! If the hood is supplied with active charcoal filter, then it must be

other fuels.

removed.

The suctioned air must not be conveyed into a conduit used for the disposal of

the fumes generated by appliances that combust gases or other fuels.

Filter version

The flaming of foods beneath the hood itself is severely prohibited.

Order and install 2 active carbon filters (active carbon filters are available from

The use of exposed flames is detrimental to the filters and may cause a fire risk,

your dealer).

and must therefore be avoided in all circumstances.

The filter removes the grease and smells from the extracted air before sending it

Any frying must be done with care in order to make sure that the oil does not

back into the room through the upper outlet grid.

overheat and burst into flames.

With regards to the technical and safety measures to be adopted for fume

CONTROLS

discharging it is important to closely follow the regulations provided by the

A. on/off light switch

authorised authorities.

B. on/off aspiration switch and minimum power selection

The hood must be regularly cleaned on both the inside and outside (AT LEAST

B+C. medium power selection aspiration switch

ONCE A MONTH).

B+D. maximum power selection aspiration switch

This must be completed in accordance with the maintenance instructions

E. operating gauge

provided in this manual). Failure to follow the instructions provided in this user

guide regarding the cleaning of the hood and filters will lead to the risk of fires.

Do not use or leave the hood without the lamp correctly mounted due to the

possible risk of electric shocks.

We will not accept any responsibility for any faults, damage or fires caused to the

appliance as a result of the non-observance of the instructions included in this

manual.

ELECTRICAL CONNECTION

The mains power supply must correspond to the rating indicated on the plate

situated inside the hood. If provided with a plug connect the hood to a socket in

compliance with current regulations and positioned in an accessible area. If it not

fitted with a plug (direct mains connection) or if the plug is not located in an

accessible area apply a double pole switch in accordance with standards which

assures the complete disconnection of the mains under conditions relating to

over-current category III, in accordance with installation instructions.

Warning! Before re-connecting the hood circuit to the mains supply and

checking the efficient function, always check that the mains cable is correctly

assembled.

Replacing the power cable

Warning! Power cable replacement must be undertaken by the authorised

service assistance centre or similar qualified person.

11

Maintenance of the charcoal filter

EN

MAINTENANCE

It absorbs unpleasant odours caused by cooking.

ATTENTION! Before performing any maintenance operation, isolate the hood

The saturation of the activated charcoal occurs after more or less prolonged use,

from the electrical supply by switching off at the connector and removing the

depending on the type of cooking and the regularity of cleaning of the grease

connector fuse.

filter.

Or if the appliance has been connected through a plug and socket, then the plug

In any case it is necessary to replace the cartridge at least every four mounths.

must be removed from the socket.

The carbon filter may NOT be washed or regenerated.

Cleaning

Remove the grease filter.

The cooker hood should be cleaned regularly (at least with the same frequency

Apply one on each side covering both grills protecting the motor propeller,

with which you carry out maintenance of the fat filters) internally and externally.

then turn the filter central handles P clockwise.

Clean using the cloth dampened with neutral liquid detergent. Do not use

In order to dismantle turn the central handle P anti-clockwise for each filter.

abrasive products. DO NOT USE ALCOHOL!

Put the grease filters back in place.

WARNING: Failure to carry out the basic cleaning recommendations of the

cooker hood and replacement of the filters may cause fire risks.

Therefore, we recommend oserving these instructions.

The manufacturer declines all responsibility for any damage to the motor or any

fire damage linked to inappropriate maintenance or failure to observe the above

safety recommendations.

Maintenance of the anti-grease filters

Traps cooking grease particles.

This must be cleaned once a month using non aggressive detergents, either by

hand or in the dishwasher, which must be set to a low temperature and a short

cycle. When washed in a dishwasher, the grease filter may discolour slightly, but

this does not affect its filtering capacity.

To remove the grease filter, pull the spring release handle.

Replacing lamps

Disconnect the hood from the electricity.

Warning! Prior to touching the light bulbs ensure they are cooled down.

- Remove the grease filters .

- Replace faulty bulbs, always using new bulbs of max. 40 W (E14).

- Refit the grease filters.

12

DISPOSAL

TECHNICAL DATA

EN

This appliance is marked according to the European directive 2002/96/EC on

Model H 563

Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is

Height (Ducting version) 73,3-114,8 cm

disposed of correctly, you will help prevent potential negative consequences for

Height (Filter version) 81,8-114,8 cm

the environment and human health, which could otherwise be caused by

Width 59,9 cm

inappropriate waste handling of this product.

Depth 51,5 cm

Gross weight: 12,15 Kg

Total absorption 200 W

Motor absorption 1x120 W

The symbol

on the product, or on the documents accompanying the

Lamp absorption 2x40 W (E14)

product, indicates that this appliance may not be treated as household waste.

Exhaust pipe Ø 15 cm

Instead it should be taken to the appropriate collection point for the recycling of

electrical and electronic equipment. Disposal must be carried out in accordance

Model H 573

with local environmental regulations for waste disposal.

Height (Ducting version) 73,3-114,8 cm

For more detailed information about treatment, recovery and recycling of this

Height (Filter version) 81,8-114,8 cm

product, please contact your local authority.

Width 69,9 cm

MALFUNCTIONS

Depth 51,5 cm

If something appears not to be working properly, do the following simple checks

Gross weight: 14 Kg

before calling Technical Service:

Total absorption 200 W

If the hood is not working:

Motor absorption 1x120 W

Check that:

Lamp absorption 2x40 W (E14)

- The power has not been disconnected.

Exhaust pipe Ø 15 cm

- A speed has been selected.

If the hood performs inefficiently:

Model H 593

Check that:

Height (Ducting version) 73,3-114,8 cm

- The motor speed selected is sufficient for the amount of smoke and

Height (Filter version) 81,8-114,8 cm

vapours released.

Width 89,9 cm

- The kitchen is sufficiently ventilated to allow air intake.

Depth 51,5 cm

- The charcoal filter is not worn (hood in filtering version).

Gross weight: 14,85 Kg

If the hood has turned off during normal functioning:

Total absorption 200 W

Check that:

Motor absorption 1x120 W

- The power has not been disconnected.

Lamp absorption 2x40 W (E14)

- the omnipolar disconnection device has not tripped.

Exhaust pipe Ø 15 cm

If the hood fails to operate correctly, briefly disconnect it from the mains power

This appliance conforms to the following EEC Directive:

supply for almost 5 sec. by pulling out the plug. Then plug it in again and try once

“Low Voltage Equipment” Directive 2006/95/EC (12-12-2006)

more before contacting the Technical Assistance Service.

• “Electromagnetic Compatibility” Directive 2004/108/EC (15-12-2004)

Components not provided with the product

13