Indesit PI 604: Installation

Installation: Indesit PI 604

Installation

! Before operating your new appliance please read

GB

this instruction booklet carefully. It contains important

555 mm

information for safe use, installation and care of the

appliance.

55 mm

! Please keep these operating instructions for future

reference. Pass them on to possible new owners of

475 mm

the appliance.

Positioning

Hook fastening diagram

! Keep packaging material out of the reach of

children. It can become a choking or suffocation

hazard (see Precautions and tips).

! The appliance must be installed by a qualified

20

professional according to the instructions provided.

30

Incorrect installation may cause harm to people and

animals or may damage property.

Hooking position Hooking position

for top H=20 mm for top H=30 mm

Fitting the appliance

Front

It is possible to instal them next to furniture which is

higher than the working board. For a correct

installation of the cooking top the following

precautions must be followed:

Kitchen cabinets adjacent to the appliance and

taller than the top of the hob must be at least 600

40

mm from the edge of the hob.

Hoods must be installed according to their relative

Hooking position Back

installation instruction manuals and at a minimum

for top H=40 mm

distance of 650 mm from the hob.

! Use the hooks contained in the “accessory pack”

Place the wall cabinets

adjacent to the hood at a

Where the hob is not installed over a built-in oven, a

minimum height of 420 mm

wooden panel must be installed as insulation. This

from the hob (see figure).

must be placed at a minimum distance of 20 mm

from the lower part of the hob.

If the hob is installed

beneath a wall cabinet, the

Ventilation

latter must be situated at a

minimum of 700 mm above the

To ensure adequate ventilation, the back panel of the

hob (see figure).

cabinet must be removed. It is advisable to install the

oven so that it rests on two strips of wood, or on a

The installation cavity should have the dimensions

completely flat surface with an opening of at least 45 x

indicated in the figure.

560 mm (see diagrams).

Fastening hooks are provided, allowing you to

fasten the hob to tops that are between 20 and 40

mm thick. To ensure the hob is securely fastened to

the top, we recommend you use all the hooks

provided.

9

600mm min.

700mm min.

600mm min.

380-400V 3N~

1 2

3

4

5

GB

H05RR-F 5x1.5 CEI-UNEL 35363

R

S

T

N

380-400V 2N~

12345

H05RR-F 4x1.5 CEI-UNEL 35363

R

S

N

220-230V 1N~

1

2

3

4

5

H05RR-F 3x2.5 CEI-UNEL 35363

R

N

Where a hob is installed above an oven without a

Connecting the supply cable to the mains

forced ventilation cooling system, adequate ventilation

must be provided inside the cabinet by means of air

Install a standardised plug corresponding to the load

holes through which air can pass (see figure).

indicated on the data plate.

The appliance must be directly connected to the mains

using an omnipolar circuit-breaker with a minimum

contact opening of 3 mm installed between the

appliance and the mains. The circuit-breaker must be

suitable for the charge indicated and must comply with

current electrical regulations (the earthing wire must not

be interrupted by the circuit-breaker). The supply cable

must not come into contact with surfaces with

temperatures higher than 50°C.

Electrical connection

! The installer must ensure that the correct electrical

connection has been made and that it is compliant

The electric hobs are supplied without power supply

with safety regulations.

cable since the cable must be sized according to the

Before connecting to the power supply, make sure

type of electrical connection used (see attached

that:

connection diagram). Follow these steps to connect

the cable:

The appliance is earthed and the plug is compliant

with the law.

Open the terminal box by removing the screws "V"

and opening the cover (see figure).

The socket can withstand the maximum power of

the appliance, which is indicated on the data plate.

Connect the wires as shown in the diagram.

The voltage is in the range between the values

Fix the cable using the cable clamp "F", replace the

indicated on the data plate.

cover and fasten it using the screws "V" (see figure).

The socket is compatible with the plug of the

V

1

2

3

4

5

appliance. If the socket is incompatible with the

plug, ask an authorised technician to replace it. Do

not use extension cords or multiple sockets.

! Once the appliance has been installed, the power

supply cable and the electrical socket must be easily

accessible.

! The cable must not be bent or compressed.

F

! The cable must be checked regularly and replaced

by authorised technicians only (see Assistance).

! The manufacturer declines any liability should these

safety measures not be observed.

! If the appliance is to be installed above a built-in

electric oven, the electrical connection of the hob and

the oven must be carried out separately, both for

electrical safety purposes and to make extracting the

oven easier.

10

45 mm.

560 mm.