Indesit H563IX: English
English: Indesit H563IX

English
11
EN
!
It is important to conserve this booklet for consultation at any moment. In
the case of sale, cession or move, make sure it is together with the product.
!
Read the instructions carefully: there is important information about
installation, use and safety.
!
Do not carry out electrical or mechanical variations on the product or on the
discharge conduits.
GENERAL SAFETY
The minimum distance between the supporting surface for the cooking
equipment on the hob and the lowest part of the range hood must be not less
than 60cm from electric cookers and 70cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this
must be adhered to.
Expansion wall plugs are provided to secure the hood to most types of
walls/ceilings. However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling. The wall/ceiling must be
strong enough to take the weight of the hood.
Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
WARNING!
Do not connect the appliance to the mains until the installation is
fully complete.
Before any cleaning or maintenance operation, disconnect hood from the mains
by removing the plug or disconnecting the mains electrical supply.
Always wear work gloves for all installation and maintenance operations.
The appliance is not intended for use by children or persons with impaired
physical, sensorial or mental faculties, or if lacking in experience or know-how,
unless they are under supervision or have been trained in the use of the
appliance by a person responsible for their safety.
Children should be monitored to ensure that they do not play with the appliance.
This appliance is designed to be operated by adults. Children should not be
allowed to tamper with the controls or play with the appliance.Never use the
hood without effectively mounted grating!
The hood must NEVER be used as a support surface unless specifically
indicated.
The premises where the appliance is installed must be sufficiently ventilated,
when the kitchen hood is used together with other gas combustion devices or
other fuels.
The suctioned air must not be conveyed into a conduit used for the disposal of
the fumes generated by appliances that combust gases or other fuels.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may cause a fire risk,
and must therefore be avoided in all circumstances.
Any frying must be done with care in order to make sure that the oil does not
overheat and burst into flames.
With regards to the technical and safety measures to be adopted for fume
discharging it is important to closely follow the regulations provided by the
authorised authorities.
The hood must be regularly cleaned on both the inside and outside (AT LEAST
ONCE A MONTH).
This must be completed in accordance with the maintenance instructions
provided in this manual). Failure to follow the instructions provided in this user
guide regarding the cleaning of the hood and filters will lead to the risk of fires.
Do not use or leave the hood without the lamp correctly mounted due to the
possible risk of electric shocks.
We will not accept any responsibility for any faults, damage or fires caused to the
appliance as a result of the non-observance of the instructions included in this
manual.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket in
compliance with current regulations and positioned in an accessible area. If it not
fitted with a plug (direct mains connection) or if the plug is not located in an
accessible area apply a double pole switch in accordance with standards which
assures the complete disconnection of the mains under conditions relating to
over-current category III, in accordance with installation instructions.
Warning!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is correctly
assembled.
Replacing the power cable
Warning!
Power cable replacement must be undertaken by the authorised
service assistance centre or similar qualified person.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to
the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause
a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct with an as smooth as possible inside.
!
The duct must be made of certified material.
!
The company declines any responsibility whenever these regulations are
not respected.
FILTERING OR DUCTING ?
!
Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY KIT must be
installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished
or must be bought separately.
Note:
If furnished, in certain cases, the additional activated carbon filtering
system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering
version is present in this manual.
Ducting version
In this case the fumes are conveyed outside by means of a special pipe
connected with the connection ring located on top of the hood.
Attention
! The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring =
150mm.
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°)
and directed upwards to vent the air easily from the room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it must be
removed.
Filter version
Order and install 2 active carbon filters (active carbon filters are available from
your dealer).
The filter removes the grease and smells from the extracted air before sending it
back into the room through the upper outlet grid.
CONTROLS
A.
on/off light switch
B.
on/off aspiration switch and minimum power selection
B+C.
medium power selection aspiration switch
B+D.
maximum power selection aspiration switch
E.
operating gauge

12
EN
MAINTENANCE
ATTENTION!
Before performing any maintenance operation, isolate the hood
from the electrical supply by switching off at the connector and removing the
connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug
must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the same frequency
with which you carry out maintenance of the fat filters) internally and externally.
Clean using the cloth dampened with neutral liquid detergent. Do not use
abrasive products.
DO NOT USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to the motor or any
fire damage linked to inappropriate maintenance or failure to observe the above
safety recommendations.
Maintenance of the anti-grease filters
Traps cooking grease particles.
This must be cleaned once a month using non aggressive detergents, either by
hand or in the dishwasher, which must be set to a low temperature and a short
cycle. When washed in a dishwasher, the grease filter may discolour slightly, but
this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Maintenance of the charcoal filter
It absorbs unpleasant odours caused by cooking.
The saturation of the activated charcoal occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least every four mounths.
The carbon filter may NOT be washed or regenerated.
•
Remove the grease filter.
•
Apply one on each side covering both grills protecting the motor propeller,
then turn the filter central handles
P
clockwise.
•
In order to dismantle turn the central handle
P
anti-clockwise for each filter.
•
Put the grease filters back in place.
Replacing lamps
Disconnect the hood from the electricity.
Warning!
Prior to touching the light bulbs ensure they are cooled down.
- Remove the grease filters .
- Replace faulty bulbs, always using new bulbs of
max. 40 W (E14).
- Refit the grease filters.

13
EN
DISPOSAL
This appliance is marked according to the European directive 2002/96/EC on
Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product.
The symbol
on the product, or on the documents accompanying the
product, indicates that this appliance may not be treated as household waste.
Instead it should be taken to the appropriate collection point for the recycling of
electrical and electronic equipment. Disposal must be carried out in accordance
with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this
product, please contact your local authority.
MALFUNCTIONS
If something appears not to be working properly, do the following simple checks
before calling Technical Service:
•
If the hood is not working:
Check
that:
- The power has not been disconnected.
- A speed has been selected.
•
If the hood performs inefficiently:
Check
that:
- The motor speed selected is sufficient for the amount of smoke and
vapours released.
- The kitchen is sufficiently ventilated to allow air intake.
- The charcoal filter is not worn (hood in filtering version).
•
If the hood has turned off during normal functioning:
Check
that:
- The power has not been disconnected.
- the omnipolar disconnection device has not tripped.
If the hood fails to operate correctly, briefly disconnect it from the mains power
supply for almost 5 sec. by pulling out the plug. Then plug it in again and try once
more before contacting the Technical Assistance Service.
TECHNICAL DATA
Model H 563
Height (Ducting version)
73,3-114,8 cm
Height (Filter version)
81,8-114,8 cm
Width
59,9 cm
Depth
51,5 cm
Gross weight:
12,15 Kg
Total absorption
200 W
Motor absorption
1x120 W
Lamp absorption
2x40 W (E14)
Exhaust pipe Ø
15 cm
Model H 573
Height (Ducting version)
73,3-114,8 cm
Height (Filter version)
81,8-114,8 cm
Width
69,9 cm
Depth
51,5 cm
Gross weight:
14 Kg
Total absorption
200 W
Motor absorption
1x120 W
Lamp absorption
2x40 W (E14)
Exhaust pipe Ø
15 cm
Model H 593
Height (Ducting version)
73,3-114,8 cm
Height (Filter version)
81,8-114,8 cm
Width
89,9 cm
Depth
51,5 cm
Gross weight:
14,85 Kg
Total absorption
200 W
Motor absorption
1x120 W
Lamp absorption
2x40 W (E14)
Exhaust pipe Ø
15 cm
This appliance conforms to the following EEC Directive:
•
“Low Voltage Equipment” Directive 2006/95/EC (12-12-2006)
• “Electromagnetic
Compatibility”
Directive 2004/108/EC (15-12-2004)
Components not provided with the product