Indesit PIM 604: Installation
Installation: Indesit PIM 604
Installation
! Before operating your new appliance please read
GB
this instruction booklet carefully. It contains important
555 mm
information for safe use, installation and care of the
appliance.
55 mm
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of
475 mm
the appliance.
Positioning
Hook fastening diagram
! Keep packaging material out of the reach of
children. It can become a choking or suffocation
hazard (see Precautions and tips).
! The appliance must be installed by a qualified
20
professional according to the instructions provided.
30
Incorrect installation may cause harm to people and
animals or may damage property.
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Fitting the appliance
Front
It is possible to instal them next to furniture which is
higher than the working board. For a correct
installation of the cooking top the following
precautions must be followed:
• Kitchen cabinets adjacent to the appliance and
taller than the top of the hob must be at least 600
40
mm from the edge of the hob.
• Hoods must be installed according to their relative
Hooking position Back
installation instruction manuals and at a minimum
for top H=40 mm
distance of 650 mm from the hob.
! Use the hooks contained in the “accessory pack”
• Place the wall cabinets
adjacent to the hood at a
• Where the hob is not installed over a built-in oven, a
minimum height of 420 mm
wooden panel must be installed as insulation. This
from the hob (see figure).
must be placed at a minimum distance of 20 mm
from the lower part of the hob.
• If the hob is installed
beneath a wall cabinet, the
Ventilation
latter must be situated at a
minimum of 700 mm above the
To ensure adequate ventilation, the back panel of the
hob (see figure).
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
• The installation cavity should have the dimensions
completely flat surface with an opening of at least 45 x
indicated in the figure.
560 mm (see diagrams).
Fastening hooks are provided, allowing you to
fasten the hob to tops that are between 20 and 40
mm thick. To ensure the hob is securely fastened to
the top, we recommend you use all the hooks
provided.
9
600mm min.
700mm min.
600mm min.
380-400V 3N~
1 2
3
4
5
GB
H05RR-F 5x1.5 CEI-UNEL 35363
R
S
T
N
380-400V 2N~
12345
H05RR-F 4x1.5 CEI-UNEL 35363
R
S
N
220-230V 1N~
1
2
3
4
5
H05RR-F 3x2.5 CEI-UNEL 35363
R
N
Where a hob is installed above an oven without a
Connecting the supply cable to the mains
forced ventilation cooling system, adequate ventilation
must be provided inside the cabinet by means of air
Install a standardised plug corresponding to the load
holes through which air can pass (see figure).
indicated on the data plate.
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The circuit-breaker must be
suitable for the charge indicated and must comply with
current electrical regulations (the earthing wire must not
be interrupted by the circuit-breaker). The supply cable
must not come into contact with surfaces with
temperatures higher than 50°C.
Electrical connection
! The installer must ensure that the correct electrical
connection has been made and that it is compliant
The electric hobs are supplied without power supply
with safety regulations.
cable since the cable must be sized according to the
Before connecting to the power supply, make sure
type of electrical connection used (see attached
that:
connection diagram). Follow these steps to connect
the cable:
• The appliance is earthed and the plug is compliant
with the law.
• Open the terminal box by removing the screws "V"
and opening the cover (see figure).
• The socket can withstand the maximum power of
the appliance, which is indicated on the data plate.
• Connect the wires as shown in the diagram.
• The voltage is in the range between the values
• Fix the cable using the cable clamp "F", replace the
indicated on the data plate.
cover and fasten it using the screws "V" (see figure).
• The socket is compatible with the plug of the
V
1
2
3
4
5
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
! The cable must not be bent or compressed.
F
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should these
safety measures not be observed.
! If the appliance is to be installed above a built-in
electric oven, the electrical connection of the hob and
the oven must be carried out separately, both for
electrical safety purposes and to make extracting the
oven easier.
10
45 mm.
560 mm.
Оглавление
- Istruzioni per l’uso
- Installazione
- Descrizione dell’apparecchio
- Precauzioni e consigli
- Manutenzione e cura
- Assistenza
- Operating Instructions
- Installation
- Description of the appliance
- Precautions and tips
- Maintenance and care
- Mode d’emploi
- Installation
- Description de l’appareil
- Précautions et conseils
- Nettoyage et entretien
- Manual de instrucciones
- Instalación
- Descripción del aparato
- Precauciones y consejos
- Mantenimiento y cuidados
- Instruções para utilização
- Instalação
- Descrição do aparelho
- Precauções e conselhos
- Manutenção e cuidados
- Gebruiksaanwijzing
- Het installeren
- Beschrijving van het apparaat
- Voorzorgsmaatregelen en advies
- Onderhoud en verzorging
- Bedienungsanleitung
- Installation
- Beschreibung des Gerätes
- Vorsichtsmaßregeln und Hinweise
- Reinigung und Pflege
- Инструкция по эксплуатации
- Установка
- Описание изделия
- Предосторожности и рекомендации
- Техническое обслуживание и уход