Error Code Message Information

Action Check system hardware inventory and software configuration.

SEC0600

Message A secure mode violation detected.

Details This may apply to a physical or remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEC0602

Message User password violation detected.

Details This may apply to a physical or remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEC0604

Message A setup password violation detected.

Details This may apply to a physical or remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEC0606

Message The network boot password violation detected.

Details This may apply to a physical or remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEC0608

Message A password violation detected.

Details This may apply to a physical or remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEC0610

Message An Out-of-band password violation detected.

Details This may apply to a remote access attempt.

Action Check system logs for intrusion attempts, and ensure strong

password policies.

SEL0002

Message Logging is disabled.

Details This message is displayed when event logging of a specific type is

disabled by the user.

121

Error Code Message Information

Action If unintended, re-enable logging.

SEL0006

Message All event logging is disabled.

Details This message is displayed when all event logging has been disabled

by the user.

Action If unintended, re-enable logging.

SEL0008

Message Log is full.

Details When the event log is full, additional events are not written to the log.

Older events may be overwritten and lost. This message may also

appear if the user disabled event logging.

Action Backup and clear log.

SEL0010

Message Log is almost full.

Details When the event log is full, additional events are not written to the log.

Older events may be overwritten and lost.

Action Backup and clear log at the next maintained time.

SEL0012

Message Could not create or initialize the system event log.

Details If the system event log fails to initialize, platform status and failure

events are not captured. Some management software do not report

platform exceptions.

Action Reboot the management controller or iDRAC. Cycle system input

power. If problem persists call support.

SEL1204

Message An unknown system hardware failure detected.

LCD Message Unknown system hardware failure.

Details If the system event log failed to initialize platform status and failure

events are not captured. Some management software will not report

platform exceptions.

Action Re-configure system to minimum supported configuration. If issues

persists, contact support.

SEL1209

Message The platform event filter action failed.

Details System policies or permissions may prevent the action from

executing. If configured, the system does not execute the action on

122

Error Code Message Information

a platform event (such as power down, cycle, interrupt, and send

alert).

Action Review platform event configuration.

SEL1211

Message The time-stamp clock could not be synchronized.

Details The time stamp on system event log events may not correlate to the

system time.

Action Cycle system input power. If problem persists, contact support.

SEL1300

Message No bootable media found.

Details System setup displays the system boot order. The local video screen

may also show additional information. (IPMI sensor type code 1eh -

offset 00h).

Action Check system boot settings. Check if mass storage controller

configuration settings are applicable.

SEL1302

Message Non-bootable diskette detected.

Details The disk in the drive is not formatted correctly or does not contain the

necessary operating system files.

Action Replace diskette with a bootable disk.

SEL1304

Message The PXE server not found.

Details PXE is one way to boot a system from the network.

Action Check the network and PXE server configuration.

SEL1306

Message Invalid boot sector found.

Details The disk in the drive is not formatted correctly or does not contain the

necessary operating system files.

Action Replace diskette with a bootable disk.

SEL1308

Message A time-out occurred while waiting for user to select a boot source.

Details The system has failed to boot to an operating system and needs the

user to select a boot source.

Action Select boot source within the time allowed.

SEL1501

Message Chassis management controller (CMC) redundancy is lost.

123

Error Code Message Information

Details An action or failure has taken place that breaks CMC redundancy.

Action Check the CMC network cables and network connections. Check that

CMC firmware versions match.

SEL1502

Message Chassis management controller (CMC) redundancy is degraded.

Details An action or failure has taken place that breaks CMC redundancy.

Action Check the CMC network cables and network connections. Check that

CMC firmware versions match.

SEL1504

Message The chassis management controller (CMC) is not redundant.

Insufficient resources to maintain normal operations.

Details There is not enough available power for two CMC's to operate.

Action Check the overall power consumption and power status.

SEL1506

Message Lost communications with Chassis Group Member <

number

>.

Details The primary CMC has lost communication with the indicated member

CMC.

Action Check the network cable and network connections.

SEL1508

Message Member <

number

> could not join the Chassis Group.

Details The indicated member CMC is a leader of a different CMC stacking

group.

Action Check if member CMC is a leader of a different chassis group.

SEL1510

Message An authentication error detected for Chassis Group Member

<

number

>.

Details Group master CMC could not log into the group member CMC.

Action Check the login credentials of CMC.

SEL9900

Message An unsupported event occurred.

Details The current software version cannot decode this event. You may

need to review this event using a tool which displays raw data such

as Ipmitool with the -vvv option or Racadm with the -E option.

Action Upgrade the management software.

124

Error Code Message Information

SWC4004

Message A firmware or software incompatibility detected between iDRAC in

slot <

number

> and CMC.

Details FlexAddress is not implemented in one of the versions of firmware.

Action Check the firmware versions of iDRAC and CMC. Update with the

latest version.

SWC4006

Message A firmware or software incompatibility detected between system

BIOS in slot <

number

> and CMC.

Details FlexAddress is not implemented in one of the versions of firmware.

Action Check the firmware versions of BIOS and CMC. Update with the latest

version.

SWC4008

Message A firmware or software incompatibility detected between CMC 1 and

CMC 2.

Details FlexAddress is not implemented in one of the versions of firmware.

Please update the firmware.

Action Check firmware versions. Update CMC 1 and CMC 2 firmware to

match.

SWC5001

Message <

name

> upgrade failed.

Action Reboot the system and attempt the upgrade again.

TMP0100

Message The system board <

name

> temperature is less than the lower

warning threshold.

LCD Message System board <

name

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0101

Message The system board <

name

> temperature is less than the lower critical

threshold.

LCD Message System board <

name

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0102

Message The system board <

name

> temperature is greater than the upper

warning threshold

125

Error Code Message Information

LCD Message System board <

name

> temperature is outside of range.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action The system board <

name

> temperature is outside of the optimum

range. Check the fans.

TMP0103

Message The system board <

name

> temperature is greater than the upper

critical threshold.

LCD Message System board <

name

> temperature is outside of range.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action The system board <

name

> temperature is outside of the optimum

range. Check the fans.

TMP0104

Message The system board <

name

> temperature is outside of range.

LCD Message System board <

name

> temperature is outside of range.

Details Ambient air temperature is too warm or cool.

Action The system board <

name

> temperature is outside of the optimum

range. Check Fans.

TMP0106

Message The memory module <

number

> temperature is less than the lower

warning threshold.

LCD Message Memory module <

number

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0107

Message The memory module <

number

> temperature is less than the lower

critical threshold.

LCD Message Memory module <

number

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0108

Message The memory module <

number

> temperature is greater than the upper

warning threshold.

LCD Message Memory module <

number

> temperature is outside of range. Check

Fans.

126

Error Code Message Information

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action The system board <

name

> temperature is outside of the optimum

range. Check Fans.

TMP0109

Message The memory module <

number

> temperature is greater than the upper

critical threshold.

LCD Message Memory module <

number

> temperature is outside of range. Check

Fans.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action The system board <

name

> temperature is outside of the optimum

range. Check Fans.

TMP0110

Message The memory module <

number

> temperature is outside of range.

LCD Message Memory module <

number

> temperature is outside of range. Check

Fans.

Details Ambient air temperature is too warm or cool.

Action Check the system operating environment.

TMP0112

Message The <

name

> temperature is less than the lower warning threshold.

LCD Message The <

name

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0113

Message The <

name

> temperature is less than the lower critical threshold.

LCD Message The <

name

> temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0114

Message The <

name

> temperature is greater than the upper warning

threshold.

LCD Message The <

name

> temperature is outside of range. Check Fans

Details Ambient air temperature is too warm or one or more fans may have

failed.

127

Error Code Message Information

Action Check the system operating environment and review event log for fan

failures.

TMP0115

Message The <

name

> temperature is greater than the upper critical threshold.

LCD Message The <

name

> temperature is outside of range. Check Fans

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action Check the system operating environment and review event log for fan

failures.

TMP0116

Message The <

name

> temperature is outside of range.

LCD Message The <

name

> temperature is outside of range. Check Fans

Action Check the system operating environment and review event log for fan

failures.

TMP0118

Message The system inlet temperature is less than the lower warning

threshold.

LCD Message System inlet temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0119

Message The system inlet temperature is less than the lower critical threshold.

LCD Message System inlet temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0120

Message The system inlet temperature is greater than the upper warning

threshold.

LCD Message System inlet temperature is outside of range.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action Check the system operating environment and review event log for fan

failures.

TMP0121

Message The system inlet temperature is greater than the upper critical

threshold.

128

Error Code Message Information

LCD Message System inlet <

name

> temperature is outside of range. Check Fans.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action Check the system operating environment and review event log for fan

failures.

TMP0122

Message The system inlet temperature is outside of range.

LCD Message System inlet <

name

> temperature is outside of range. Check Fans.

Details Ambient air temperature is too warm or cool.

Action Check the system operating environment and review event log for fan

failures.

TMP0100

Message Disk drive bay temperature is less than the lower warning threshold.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0104

Message Disk drive bay temperature is less than the lower critical threshold.

LCD Message Disk drive bay temperature is outside of range. Check Fans.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0126

Message Disk drive bay temperature is greater than the upper warning

threshold.

LCD Message Disk drive bay temperature is outside of range. Check Fans.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action Check the system operating environment and review event log for fan

failures.

TMP0128

Message Disk drive bay temperature is outside of the allowable range.

LCD Message Disk drive bay temperature is outside of range. Check Fans.

Details Ambient air temperature is too warm or cool.

Action Check the system operating environment and review event log for fan

failures.

129

Error Code Message Information

TMP0130

Message The control panel temperature is less than the lower warning

threshold.

LCD Message Control panel temperature is outside of range.

Details Ambient air temperature is too cool.

Action Check the system operating environment.

TMP0132

Message The control panel temperature is greater than the upper warning

threshold.

LCD Message Control panel temperature is outside of range.

Details Ambient air temperature is too warm or one or more fans may have

failed.

Action Check the system operating environment and review event log for fan

failures.

TMP0134

Message The control panel temperature is outside of the allowable range.

LCD Message Control panel temperature is outside of range.

Details Ambient air temperature is too warm or cool.

Action Check the system operating environment and review event log for fan

failures.

VLT0100

Message Processor module <

name

> voltage is less than the lower warning

threshold.

LCD Message Processor module <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0101

Message Processor module <

name

> voltage is less than the lower critical

threshold.

LCD Message Processor module <

name

> voltage is outside of range.

130

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0102

Message Processor module <

name

> voltage is greater than the upper warning

threshold.

LCD Message Processor module <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0103

Message Processor module <

name

> voltage is greater than the upper critical

threshold.

LCD Message Processor module <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0104

Message Processor module <

name

> voltage is outside of the allowable range.

LCD Message Processor module <

name

> voltage is outside of range.

131

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0200

Message The system board <

name

> voltage is less than the lower critical

threshold.

LCD Message System board voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see Getting Help.

VLT0201

Message The system board <

name

> voltage is less than the lower warning

threshold.

LCD Message System board voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0202

Message The system board <

name

> voltage is greater than the upper warning

threshold.

LCD Message System board voltage is outside of range.

132

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0203

Message The system board <

name

> voltage is greater than the upper critical

threshold.

LCD Message System board voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0204

Message The system board <

name

> voltage is outside of the allowable range.

LCD Message System board voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0206

Message The memory module <

number

> <

name

> voltage is less than the lower

warning threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

133

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0207

Message The memory module <

number

> <

name

> voltage is less than the lower

critical threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0208

Message The memory module <

number

> <

name

> voltage is greater than the

upper warning threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0209

Message The memory module <

number

> <

name

> voltage is greater than the

upper critical threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

134

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0210

Message The memory module <

number

> <

name

> voltage is outside of range.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0212

Message The disk drive bay <

name

> voltage is less than the lower warning

threshold.

LCD Message The disk drive bay <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0213

Message The disk drive bay <

name

> voltage is less than the lower critical

threshold.

LCD Message The disk drive bay <

name

> voltage is outside of range.

135

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0214

Message The disk drive bay <

name

> voltage is greater than the upper critical

threshold.

LCD Message The disk drive bay <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0215

Message The disk drive bay <

name

> voltage is greater than the upper critical

threshold.

LCD Message The disk drive bay <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0216

Message The <

name

> voltage is outside of range.

LCD Message The <

name

> voltage is outside of range.

136

Error Code Message Information

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0218

Message The <

name

> voltage is less than the lower warning threshold.

LCD Message The <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0219

Message The <

name

> voltage is less than the lower critical threshold.

LCD Message The <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0220

Message The <

name

> voltage is greater than the upper warning threshold.

LCD Message The <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

137

Error Code Message Information

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0221

Message The <

name

> voltage is greater than the upper critical threshold.

LCD Message The <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0222

Message The <

name

> voltage is outside of range.

LCD Message The <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0224

Message The memory module <

name

> voltage is less than the lower warning

threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

138

Error Code Message Information

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0225

Message The memory module <

name

> voltage is less than the lower critical

threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0226

Message The memory module <

name

> voltage is greater than the upper

warning threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0227

Message The memory module <

name

> voltage is greater than the upper critical

threshold.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

139

Error Code Message Information

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0228

Message The memory module <

name

> voltage is outside of range.

LCD Message Memory module <

number

> <

name

> voltage is outside of range.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and

reinstall system cables.

3. If the issue persists, see Getting Help.

VLT0230

Message The PCIe mezzanine card <

number

> <

name

> voltage is less than the

lower warning threshold.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-seat the PCIe mezzanine card.

3. If the issue persists, see Getting Help.

VLT0231

Message The PCIe mezzanine card <

number

> <

name

> voltage is less than the

lower critical threshold.

Details System hardware detected an over voltage or under voltage

condition.

If multiple voltage exceptions occur consecutively the system may

power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

140