Dell PowerEdge VRTX – страница 6

Инструкция к Компьютеру Dell PowerEdge VRTX

Оглавление

Error Code Message Information

PCI1302

Message A bus time-out was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded. The device has failed to

respond to a transaction.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1304

Message An I/O channel check error was detected.

LCD Message I/O channel check error detected. Power cycle system.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1306

Message A software error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Action Reboot the system and update the component drivers.

PCI1308

Message A PCI parity error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

LCD Message PCI parity error on bus <

bus

> device <

device

> function <

func

>.

Power cycle system.

Details System performance may be degraded, PCI device may fail to

operate, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1310

Message A PCI system error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

LCD Message PCI system error on bus <

bus

> device <

device

> function <

func

>.

Power cycle system.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1314

Message A bus correctable error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded.

101

Error Code Message Information

Action Cycle input power, update component drivers, if device is removable

reinstall the device at the next scheduled service time.

PCI1316

Message A bus uncorrectable error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1318

Message A fatal error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

LCD Message Fatal error on bus <

bus

> device <

device

> function <

func

>. Power

cycle system.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1320

Message A bus fatal error was detected on a component at bus

<

bus

>device<

device

>function <

func

>.

LCD Message Bus fatal error on bus <

bus

> device <

device

> function <

func

>. Power

cycle system.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1322

Message Bus performance degraded for a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded. The bus is not operating at

maximum speed or width.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1342

Message A bus time-out was detected on a component at slot <

number

>.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

102

Error Code Message Information

PCI1344

Message An I/O channel check error was detected.

LCD Message An I/O channel check error was detected. Power cycle system.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1346

Message A software error was detected on a component at slot <

number

>.

Action Reboot the system and update the component drivers.

PCI1348

Message A PCI parity error was detected on a component at slot <

number

>.

LCD Message PCI parity error on slot <

number

>. Re-seat PCI card.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1350

Message A PCI system error was detected on a component at slot <

number

>.

LCD Message PCI parity error on slot <

number

>. Re-seat PCI card.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1354

Message A bus correctable error was detected on a component at slot

<

number

>.

Details System performance may be degraded.

Action Cycle input power, update component drivers, remove and reinstall

the device at the next scheduled service time.

PCI1356

Message A bus uncorrectable error was detected on a component at slot

<

number

>.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1358

Message A fatal error was detected on a component at slot <

number

>.

LCD Message Fatal error on slot <

number

>. Re-seat PCI card.

Details System performance may be degraded, or system may fail to operate.

103

Error Code Message Information

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1360

Message A bus fatal error was detected on a component at slot <

number

>.

LCD Message Bus fatal error on slot <

number

>. Re-seat PCI card.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, if device is removable,

reinstall the device.

PCI1362

Message Bus performance degraded for a component at slot <

number

>.

Details System performance may be degraded. The bus is not operating at

maximum speed or width.

Action Cycle input power, update component drivers, remove and reinstall

the device at the next scheduled service time.

PCI2000

Message A fatal IO error detected on a component at bus

<

bus

>device<

device

>function <

func

>.

LCD Message Fatal IO error on bus <

bus

> device <

device

> function <

func

>.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, remove and reinstall

the device.

PCI2002

Message A fatal IO error detected on a component at slot <

number

>.

LCD Message Fatal IO error on slot <

number

>.

Details System performance may be degraded, or system may fail to operate.

Action Cycle input power, update component drivers, remove and reinstall

the device.

PCI3000

Message Device option ROM on embedded NIC failed to support Link Tuning or

FlexAddress.

Details Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does

not support FlexAddress.

Action Update BIOS, BMC/iDRAC, and LOM firmware. If the issue persists,

see Getting Help.

PCI3002

Message Failed to program virtual MAC address on a component at bus

<

bus

>device<

device

>function <

func

>.

104

Error Code Message Information

Details Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and

does not support FlexAddress.

Action Update BIOS, BMC/iDRAC, LOM, and PCIe mezzanine card firmware.

If the issue persists, see Getting Help.

PCI3004

Message Device option ROM on PCIe mezzanine card <

number

> failed to

support Link Tuning or FlexAddress.

Details Either the BIOS, BMC/iDRAC, or PCIe mezzanine card firmware is out

of date and does not support FlexAddress.

Action Update BIOS, BMC/iDRAC, and PCIe mezzanine card firmware. If the

issue persists, see Getting Help.

PCI3006

Message Failed to get Link Tuning or FlexAddress data from iDRAC.

Details Either the BIOS or BMC/iDRAC firmware is out of date and does not

support FlexAddress.

Action Update BIOS, and BMC/iDRAC firmware. If the issue persists, see

Getting Help.

PCI3008

Message A non-fatal PCIe error detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded.

Action Cycle input power, update component drivers, remove and reinstall

the device at the next service window.

PCI3010

Message A non-fatal IO error detected on a component at bus

<

bus

>device<

device

>function <

func

>.

Details System performance may be degraded.

Action Cycle input power, update component drivers, remove and reinstall

the device at the next service window.

PCI3012

Message The QuickPath Interconnect (QPI) width degraded.

Details System performance may be degraded. The bus is not operating at

maximum speed or width.

Action Reset the system, if the problem persists reinstall processors.

PCI3014

Message A non-fatal PCIe error detected on a component at slot <

number

>.

Details System performance may be degraded.

105

Error Code Message Information

Action Cycle input power, update component drivers, remove and reinstall

the device at the next scheduled service time.

PDR0001

Message Fault detected on drive <

number

>.

LCD Message Fault detected on drive <

number

>. Check drive.

Details The controller detected a failure on the disk and has taken the disk

offline.

Action Remove and re-seat the failed disk. If the issue persists, see Getting

Help.

PDR0002

Message A predictive failure detected on drive <

number

>.

Details The controller received a SMART error from the drive. The drive is

operational but needs replacement.

Action The drive will need replacement at the next service window.

PDR0016

Message Drive <

number

> is removed.

LCD Message Drive <

number

> is removed. Check drive.

Details The controller detected a drive removal.

Action If unintended, verify drive installation. Remove and re-seat the

indicated disk. If the issue persists, see Getting Help.

PDR1001

Message Fault detected on drive <

number

> in disk drive bay <

bay

>.

LCD Message Fault detected on drive <

number

> in disk drive bay <

bay

>. Check

drive.

Details The controller detected a failure on the disk and has taken the disk

offline.

Action Re-seat the failed drive. If the issue persists, see Getting Help.

PDR1002

Message A predictive failure detected on drive <

number

> in disk drive

bay<

bay

>.

Details The controller received a SMART error from the drive. The drive is

operational but needs replacement.

Action The drive will need replacement at the next service window.

PDR1016

Message Drive <

number

> is removed from disk drive bay <

bay

>.

LCD Message Drive <

number

> removed from disk drive bay <

bay

>. Check drive.

106

Error Code Message Information

Details The controller detected that the drive was removed.

Action Verify drive installation. Re-seat the failed drive. If the issue persists,

see Getting Help.

PDR1024

Message Drive mismatch detected for drive <

number

> in disk drive bay <

bay

>.

LCD Message Drive mismatch detected for drive <

number

> in bay <

bay

>. Install

correct drive type.

Details The installed disk does not meet the array requirements, for example

a SATA disk may not operate in an array containing SAS drives.

Action Verify that the disk meets the array requirements.

PST0128

Message No memory is detected.

LCD Message No memory is detected. Inspect memory devices.

Details System BIOS was unable to detect memory in the system .

Action Re-seat the memory modules. If the issue persists, see Getting Help.

PST0129

Message Memory is detected, but is not configurable.

LCD Message Memory is detected, but is not configurable. Check memory devices.

Details System BIOS detected memory, but was unable to configure the

memory for system operation.

Action Compare system memory installation to supported system memory

configurations.

PST0130

Message Memory is configured, but not usable.

LCD Message Memory is configured, but not usable. Check memory devices

Details The system BIOS encountered device failures or speed

configurations that resulted in unused memory.

Action Re-seat the memory modules. If the issue persists, see Getting Help.

PST0131

Message System BIOS shadow failed.

LCD Message System BIOS shadow failed. Check memory devices.

Details Memory errors occurred copying BIOS image into system memory.

Action Remove input power. Reduce system memory to minimum

configuration and apply input power.

107

Error Code Message Information

PST0132

Message CMOS failed.

LCD Message CMOS failed. Power cycle system.

Details System BIOS detected a failure with CMOS memory during system

POST.

Action Check system event log for CMOS battery exceptions. Remove and

reapply input power. If the issue persists, see Getting Help.

PST0133

Message DMA controller failed.

LCD Message DMA controller failed. Power cycle system.

Details System BIOS detected a failure with the DMA controller during

system POST.

Action Remove and reapply input power.

PST0134

Message Interrupt controller failed.

LCD Message Interrupt controller failed. Power cycle system.

Details System BIOS detected a failure with the interrupt controller during

system POST.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0135

Message Timer refresh failed.

LCD Message Timer refresh failed. Power cycle system..

Details System BIOS detected a timer refresh failure during system POST.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0136

Message Programmable interval timer error.

LCD Message Programmable interval timer error. Power cycle system.

Details System BIOS detected an failure with the programmable interval

timer during POST.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0137

Message Parity error.

LCD Message Parity error. Power cycle system.

108

Error Code Message Information

Details System BIOS detected a parity error during post.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0138

Message SuperIO failed.

LCD Message SuperIO failure. Power cycle system.

Details System BIOS detected a failure with the SIO.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0139

Message Keyboard controller failed.

LCD Message Keyboard controller failed. Power cycle system.

Details System BIOS detected a failure with the Keyboard Controller.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0140

Message System management interrupt initialization failed.

LCD Message SMI initialization failed. Power cycle system.

Details System BIOS failed to initialize the system management interrupt.

Action Remove and reapply input power. If the issue persists, see Getting

Help.

PST0141

Message QuickPath Interconnect (QPI) fatal error.

LCD Message QuickPath Interconnect (QPI) fatal error.

Details Quick Path Interconnect failed during system POST.

Action Reboot the system. If problem persists, remove input power and re-

seat processors.

PST0142

Message MRC fatal error.

LCD Message Memory initialization error.

Details BIOS Memory testing failed.

Action Compare system memory installation to supported system memory

configurations. Reduce system configuration to minimum memory

configuration.

109

Error Code Message Information

PST0143

Message Intel Trusted Execution Technology (TXT) fatal error.

LCD Message Intel Trusted Execution Technology (TXT) fatal error.

Details TXT boot failed. This could be related to memory errors or an error

with the system TXT configuration. A socketed TPM module may

have been removed.

Action Check TPM presence. Remove and reapply input power. If the issue

persists, see Getting Help.

PST0192

Message Shut-down test failed.

LCD Message Shut-down test failed. Power cycle system.

Details System BIOS shutdown test failed during POST.

Action Check system event log for CMOS battery exceptions. Remove and

reapply input power. If the issue persists, see Getting Help.

PST0193

Message BIOS POST memory test failed.

LCD Message BIOS POST memory test failed. Check memory devices.

Details System BIOS POST memory test failed.

Action Compare system memory installation to supported system memory

configurations. Reduce system configuration to minimum memory

configuration.

PST0194

Message Remote access controller configuration failed.

LCD Message Remote access controller configuration failed. Check screen

message.

Details System BIOS could not configure the Remote Access controller.

Action Cycle input power and power on the system. If the issue persists, see

Getting Help.

PST0195

Message CPU configuration failed.

LCD Message CPU configuration failed. Check screen message.

Details The current processor configuration is unsupported or encountered a

fatal exception during POST.

Action Review system processor configuration and reduce the system to the

minimum configuration.

PST0196

Message Incorrect memory configuration.

110

Error Code Message Information

LCD Message Incorrect memory configuration. Review User Guide.

Details System BIOS detected an invalid memory population.

Action Reinstall memory to match supported memory configuration.

PST0254

Message General failure after video.

LCD Message General failure after video. Check screen message.

Details System BIOS detected a functional or configuration issue during

system POST.

Action Check system video and review event log for additional information.

PST0256

Message POST fatal error detected.

LCD Message POST fatal error detected.

Details System BIOS detected a functional or configuration issue during

system POST.

Action Check system video and review event log for additional information.

PSU0001

Message Power supply <

number

> failed.

LCD Message PSU <

number

> failed. Check PSU.

Action Remove and reinstall the power supply. If the issue persists, see

Getting Help.

PSU0002

Message A predictive failure detected on power supply <

number

>.

LCD Message Predictive failure on PSU <

number

>. Check PSU.

Details System performance and power redundancy may be degraded or

lost.

Action Remove and reinstall the power supply at the next service window. If

the issue persists, see Getting Help.

PSU0003

Message The power input for power supply <

number

> is lost.

LCD Message Power input for PSU <

number

> is lost. Check PSU cables.

Details The power supply is installed correctly but an input source is not

connected or is not functional.

Action Verify the input source is attached to the power supply. Verify the

input power is within the operating requirements for the power

supply.

111

Error Code Message Information

PSU0004

Message The power input for power supply <

number

> is outside of the

allowable range.

LCD Message Power input for PSU <

number

> is outside of range. Check PSU

cables.

Details The operating requirements for the power supply may be found in this

manual or on the power supply itself.

Action Verify the input source is attached to the power supply. Verify the

input power is within the operating requirements for the power

supply.

PSU0005

Message The power input for power supply <

number

> is outside of the

allowable range, but it is attached to the system.

Details The operating requirements for the power supply may be found in this

manual or on the power supply itself.

Action Verify the input power is within the operating requirements for the

power supply.

PSU0006

Message Power supply <

number

> type mismatch.

LCD Message Power supply <

number

> is incorrectly configured. Check PSU.

Details Power supplies should be of the same input type and power rating.

Action Install matched power supplies and review proper configuration in

this manual.

PSU0007

Message Power supply <

number

> is operating at 110 volts, and could cause a

circuit breaker fault.

Details A power supply that is designed to operate at 220V, but is connected

to a 110V power source requires additional current for operation. The

additional current may trip circuit-breakers or cause other electrical

issues with the input source.

Action Check input power source and cabling. Use recommended input

power. Review this Manual. If the issue persists, see Getting Help.

PSU0008

Message Power supply <

number

> voltage rating does not match the system's

requirements.

Details The system does not support mixed voltage power supplies.

Action Install a power supply with the correct voltage rating.

PSU0016

Message Power supply <

number

> is absent.

112

Error Code Message Information

LCD Message PSU <

number

> is absent. Check PSU.

Details The supply has been removed or has failed.

Action

1. Remove and reinstall the power supply.

2. Check cables and subsystem components in the system for

damage.

3. If the issue persists, see Getting Help.

PSU0031

Message Cannot communicate with power supply <

number

>.

LCD Message Cannot communicate with PSU <

number

>. Re-seat PSU.

Details The power supply may operate, however power supply monitoring

will be degraded. System performance may be degraded.

Action Remove and reinstall the power supply. If the issue persists, see

Getting Help.

PSU1201

Message Power supply redundancy is lost.

Details The power supply will try to operate in a degraded state. System

Performance and power redundancy may be degraded or lost.

Action Check input power. Reinstall the power supply. If the issue persists,

see Getting Help.

PSU1202

Message Power supply redundancy is degraded.

Details The power supply will try to operate in a degraded state. System

Performance and power redundancy may be degraded or lost.

Action Remove input power and reinstall supply at the next service window.

PSU1203

Message The power supplies are not redundant.

LCD Message Lost PSU redundancy. Check PSU cables.

Details The current power operational mode is non-redundant because of a

power supply exception, a power supply inventory change, or a

system power inventory change.

Action Check the event log for power supply failures. Review system

configuration and power consumption.

PSU1204

Message The power supplies are not redundant. Insufficient resources to

maintain normal operations.

LCD Message PSU redundancy degraded. Check PSU cables.

113

Error Code Message Information

Details The current power operational mode is non-redundant because of a

power supply exception, a power supply inventory change, or a

system power inventory change.

Action Check the event log for power supply failures. Review system

configuration and power consumption.

PWR1001

Message The system performance was degraded.

LCD Message System performance degraded. Check PSUs and system

configuration.

Details To avoid shutdown, system performance has been degraded.

Action Review system configuration and system logs for thermal or

environmental failures and warnings.

PWR1002

Message The system performance degraded because of thermal protection.

Details To avoid shutdown, system performance has been degraded.

Action Review system configuration and system logs for thermal or

environmental failures and warnings.

PWR1003

Message The system performance degraded because cooling capacity has

changed.

Details The current power supply configuration does not meet the platform

requirements to enable redundancy. If a power supply fails the

system may shutdown.

Action If unintended, review system configuration and power consumption

and install power supplies accordingly. Check power supply status

for failures.

PWR1004

Message The system performance degraded because power capacity has

changed.

Details The system may power down or operate in a performance degraded

state.

Action Check the event log for power supply failures. Review system

configuration and power consumption and upgrade or install power

supplies accordingly.

PWR1005

Message The system performance degraded because the user-defined power

capacity has changed.

Details The user-defined power settings have affected system operation.

114

Error Code Message Information

Action If unintended, review system configuration changes and power

policy.

PWR1006

Message The system halted because system power exceeds capacity.

LCD Message System power demand exceeds capacity. System halted.

Details The system halted because system power exceeds capacity.

Action Review system configuration, upgrade power supplies or reduce

system power consumption.

PWR1007

Message The system performance degraded because power exceeds

capacity.

LCD Message System power exceeds capacity. Performance degraded. Check PSU

configuration.

Details The system is currently operating in a performance degraded state to

attempt protect from a power shutdown.

Action Review system configuration, upgrade power supplies or reduce

system power consumption.

PWR1008

Message The system performance degraded because power draw exceeds the

power threshold.

LCD Message System power exceeds threshold. Performance degraded. Check

PSU configuration.

Details The power threshold is configured by the user or automatically by

software based on system configuration.

Action Review system configuration, upgrade power supplies or reduce

system power consumption.

RFM1003

Message Removable Flash Media <

name

> is not IPMI-function ready.

Details The removable flash media is installed but improperly configured or

failed to initialize.

Action If unintended, reinstall the flash media and module.

RFM1005

Message Removable Flash Media <

name

> is not ready.

Details The media is being prepared or is under maintenance. If the problem

persists, reinstall the card.

Action Wait for the media to be ready.

115

Error Code Message Information

RFM1006

Message Removable Flash Media <

name

> is offline.

Details At boot, the Card Identification (CID) signature of the card is different

from the Non-volatile (NV) storage value or the card is the destination

of a copy operation that is in-progress.

Action If unintended, reinstall the flash media.

RFM1008

Message Failure detected on Removable Flash Media <

name

>.

LCD Message Removable Flash Media <

name

> failed. Check SD Card.

Details An error was reported during a SD card read or write.

Action Reseat the flash media, if the issue persists replace the media.

RFM1014

Message Removable Flash Media <

name

> is write protected.

LCD Message Removable Flash Media <

name

> is write protected. Check SD Card.

Details The card is write-protected by the physical latch on the SD card. A

write-protected card cannot be used.

Action If unintended, remove the media and disable write protection.

RFM1016

Message Media not present for Removable Flash Media <

name

>.

Details The SD card is not detected or not installed.

Action If unintended, reinstall the flash media.

RFM1021

Message Removable Flash Media is not IPMI-function ready.

Details The removable flash media is installed but improperly configured or

failed to initialize.

Action If unintended, reinstall the flash media.

RFM1022

Message Removable Flash Media is ready.

Action If unintended, reinstall the flash media.

RFM1023

Message Removable Flash Media is not ready.

Details The media is being prepared or is under maintenance. If the problem

persists, reinstall the card.

Action If unintended, reinstall the flash media.

116

Error Code Message Information

RFM1024

Message Removable Flash Media is offline.

Details At boot, the Card Identification (CID) signature of the card is different

from the Non-volatile (NV) storage value or the card is the destination

of a copy operation that is in-progress.

Action If unintended, reinstall the flash media.

RFM1026

Message Failure detected on Removable Flash Media.

Details An error is reported during a SD card read or write.

Action Reinstall the flash media, if the issue persists replace the media.

RFM1032

Message Removable Flash Media is write protected.

Details The card is write-protected by the physical latch on the SD card.

IDSDM cannot use a write-protected card.

Action If unintended, remove the media and disable write protection.

RFM1034

Message Media not present for Removable Flash Media.

Details The SD card is not detected or not installed.

Action If unintended, reinstall the flash media.

RFM1201

Message Internal Dual SD Module redundancy is lost.

LCD Message Internal Dual SD Module redundancy is lost. Check SD Card.

Details Either one of the SD card or both the SD cards are not functioning

properly.

Action Replace the failed SD card.

RFM1202

Message Internal Dual SD Module redundancy is degraded.

Details Either one of the SD card or both the SD cards are not functioning

properly.

Action Replace the failed SD card.

RFM1203

Message Internal Dual SD Module is not redundant.

Details Internal Dual SD Module is not redundant.

Action Install additional SD card and configure for redundancy if redundancy

is desired.

117

Error Code Message Information

RFM1205

Message Internal Dual SD Module is not redundant. Insufficient resources to

maintain normal operations.

LCD Message Internal Dual SD Module is not redundant. Insufficient resources.

Check SD Card.

Details The current operating configuration cannot maintain redundancy. The

unit may operate in a degraded state.

Action Review this manual and SD card configuration.

RFM2001

Message Internal Dual SD Module <

name

> is absent.

LCD Message Internal Dual SD Module <

name

> is absent. Check SD Card.

Details The SD card module is not detected or not installed.

Action If unintended, reinstall the SD module.

RFM2002

Message Internal Dual SD Module <

name

> is offline.

Details The SD card module is installed but may be improperly installed or

configured incorrectly.

Action Reinstall the SD module.

RFM2004

Message Failure detected on Internal Dual SD Module <

name

>.

LCD Message Internal Dual SD Module <

name

> failed. Check SD Card.

Details The SD card module is installed but improperly configured or failed to

initialize.

Action Reinstall the SD module and remove and reinstall SD cards.

RFM2006

Message Internal Dual SD Module <

name

> is write protected.

Details The module is write-protected. Changes may not be written to the

media.

Action If unintended, remove the media and disable write protection.

SEC0000

Message The chassis is open.

LCD Message Intrusion detected. Check chassis cover.

Details The chassis is open. System performance may be degraded, and

security may be compromised.

Action Close the chassis. Check system logs.

118

Error Code Message Information

SEC0001

Message The drive bay is open.

Details The drive bay is open. A drive may be added or removed. System

performance may be degraded.

Action Close the drive bay. Check system logs.

SEC0002

Message The I/O card area is open.

Details The I/O card area is open. I/O cards may be added or removed.

System performance may be degraded.

Action Close the I/O card area. Check system logs.

SEC0003

Message The processor area is open.

Details The processor area is open. A drive may be added or removed.

System performance may be degraded.

Action Close the processor area. Check system logs.

SEC0004

Message The LAN is disconnected.

Details The LAN is disconnected. Network performance may be degraded.

Action If unintentional, connect network cable.

SEC0005

Message Unauthorized docking is detected.

Details A removable component may have been tampered with, or installed

incorrectly, or does not meet system requirements.

Action Check removable hardware components for correct installation.

Review installation documentation.

SEC0006

Message The fan area is open.

Details The fan area is open. System performance may be degraded.

Action Close the fan area. Check system logs.

SEC0031

Message The chassis is open while the power is on.

LCD Message Intrusion detected. Check chassis cover.

Details The chassis is open. System performance may be degraded, and

security may be compromised.

Action Close the chassis. Check system logs.

119

Error Code Message Information

SEC0033

Message The chassis is open while the power is off.

LCD Message Intrusion detected. Check chassis cover.

Details The chassis was opened while the power was off. System security

may have been comprised.

Action Close the chassis and verify hardware inventory. Check system logs.

SEC0040

Message A critical stop occurred during OS load.

Details Operating system generated critical stop IPMI event. (Sensor type

code = 20H)

Action Check video and operating system logs for additional information

SEC0041

Message BIOS detected an error configuring the Intel Trusted Execution

Technology (TXT).

LCD Message BIOS detected an error configuring TXT. Check system configuration.

Details TXT initialization failure. System configuration may have changed.

Action Check system hardware inventory and software configuration.

SEC0042

Message Processor detected an error while performing an Intel Trusted

Execution Technology (TXT) operation.

LCD Message CPU detected an error while performing a TXT operation. Check

system configuration.

Details TXT CPU microcode boot failure. System configuration may have

changed.

Action Check system hardware inventory and software configuration.

SEC0043

Message BIOS Authenticated Code Module detected an Intel Trusted

Execution Technology (TXT) error during POST.

LCD Message BIOS detected a TXT error during POST. Check system configuration.

Details TXT Post failure. System configuration may have changed.

Action Check system hardware inventory and software configuration.

SEC0044

Message SINIT Authenticated Code Module detected an Intel Trusted

Execution Technology (TXT) error at boot.

LCD Message SINIT detected a TXT error at boot. Check system configuration.

Details TXT initialization failure. System configuration may have changed.

120