Dell PowerEdge C6220 II: инструкция

Раздел: Компьютерные комплектующие

Тип:

Инструкция к Dell PowerEdge C6220 II

Dell PowerEdge

C6220 II

Getting Started

With Your System

Začínáme se systémem

Mise en route du système

Handbuch zum Einstieg

mit dem System

Τα πρώτα βήματα με το σύστημά σας

Instrukcja uruchomienia systemu

Руководство по началу

работы с сервером

Pasos iniciales para su sistema

Sisteminizi Kullanmaya Başlarken

Dell PowerEdge

C6220 II

Getting Started

With Your System

Notes, Cautions, and Warnings

NOTE:

A NOTE indicates important information that helps you make better use of

your computer.

CAUTION: A CAUTION indicates potential damage to hardware or loss of

data if instructions are not followed.

WARNING: A WARNING indicates a potential for property damage,

personal injury, or death.

______________

Information in this document is subject to change without notice.

© 2013 Dell Inc. All rights reserved.

Reproduction of these materials in any manner whatsoever without the written permission

of Dell Inc. is strictly forbidden.

Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of

Dell Inc. Intel® and Intel® Xeon® are registered trademarks of Intel Corporation in the

U.S. and other countries. Red Hat Enterprise Linux® and Enterprise Linux® are

registered trademarks of Red Hat, Inc. in the United States and/or other countries.

Novell® is a registered trademark and SUSEis a trademark of Novell Inc. in the United

States and other countries. Citrix® and XenServer® are either registered trademarks or

trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®

is a registered trademarks or trademarks of VMWare, Inc. in the United States or other

countries.

Other trademarks and trade names may be used in this publication to refer to either the

entities claiming the marks and names or their products. Dell Inc. disclaims any

proprietary interest in trademarks and trade names other than its own.

Regulatory Model B08S

May 2013 P/N MYF2N Rev. A00

CAUTION: Restricted Access Location

This server is intended for installation only in restricted access locations as

defined in Cl. 1.2.7.3 of IEC 60950-1: 2001 where both these conditions apply:

Access can only be gained by service persons or by users

who have been

instructed about the reasons for the restrictions applied to the location and

about any precautions that shall be taken.

Access is through the use of a tool or lock and key, or other means of

security, and is controlled by the authority responsible for the location.

Installation and Configuration

WARNING: Before performing the following procedure, review and follow the

safety instructions that came with the system.

Getting Started With Your System | 3

Installing the Tool-Less Rail Solution

WARNING: Whenever you need to lift the system, get others to assist you.

To avoid injury, do not attempt to lift the system by yourself.

WARNING: The system is not fixed to the rack or mounted on the rails. To

avoid personal injury or damage to the system, you must adequately

support the system during installation and removal.

WARNING: To avoid a potential electrical shock hazard, a third wire safety

grounding conductor is necessary for the rack installation. The rack

equipment must provide sufficient airflow to the system to maintain proper

cooling.

CAUTION: When installing rails in a square-hole rack it is important to

ensure that the square peg slides through the square holes.

1

Push on the latch release buttons on the midpoints of the end piece to

open the rail latches. See Figure 1.

2

Align the end pieces of the rails on the vertical rack flanges to seat the

pegs in the bottom hole of the first U and the top hole of the second

U.

Getting Started With Your System | 4

NOTE:

The rails can be used in both square-hole (item 1 in the following figure)

and round-hole racks (item 2 in the following figure).

Figure 1. Pushing the Latch Release Buttons

NOTE:

To remove the rails, push on the latch release button on the midpoints

of the end piece and unseat each rail.

3

Engage the end of the rails and release the latch release button to have

the latches locked in place. See Figure 2.

Figure 2. Releasing the Latch Release Buttons

Getting Started With Your System | 5

4

On each vertical rack flange on the back, put two screw bases into the

two square holes right above the rail. See Figure 3.

5

Install the chassis stabilizer shipping brackets (optional) on the back

rack flanges.

6

Install and tighten the screws.

NOTE:

To transport systems already installed in the rack, ensure that the two

chassis stabilizer shipping brackets (optional) are in place.

Figure 3. Installing the Chassis Stabilizer Shipping Brackets

Getting Started With Your System | 6

7

Slide the system into the rack. See Figure 4.

8

Tighten the thumbscrews to secure the ears of the system to the front of

the rack flanges.

Figure 4. Installing the Chassis onto the Rack.

Getting Started With Your System | 7

OptionalConnecting the Keyboard, Mouse, and Monitor

Figure 5. OptionalConnecting the Keyboard, Mouse and Monitor

Connect the keyboard, mouse, and monitor (optional).

The connectors on the back of your system have icons indicating which cable to

plug into each connector. Be sure to tighten the screws (if any) on the monitor’s

cable connector.

Getting Started With Your System | 8

Connecting the Power Cable(s)

Figure 6. Connecting the Power Cable

Connect the system’s power cable(s) to the system and, if a monitor is used,

connect the monitor’s power cable to the monitor. Plug the other end of the

power cables into a grounded electrical outlet or a separate power source such as

an uninterrupted power supply or a power distribution unit.

Getting Started With Your System | 9

NOTE:

Your system can support up to two 1200 W power supply units (100-240 VAC

nominal input voltage) or up to two 1400 W power supply units (200-240 VAC nominal

input voltage).

Turning on the System

Figure 7. Pressing the Power Button on the Front of the System

Figure 8. Pressing the Power Button on the Back of the System

Press the power button(s) either on the front or back of the system. The power

indicators should light green.

Getting Started With Your System | 10

Complete the Operating System Setup

To install an operating system for the first time, see the installation and

configuration documentation for your operating system. Be sure the operating

system is installed before installing hardware or software not purchased with the

system.

NOTE:

See dell.com/ossupport for the latest information on supported

operating systems.

Other Information You May Need

WARNING: See the safety and regulatory information that shipped with your

system. Warranty information may be included within this document or as a

separate document.

Getting Started With Your System | 11

The Hardware Owner’s Manual provides information about system features and

describes how to troubleshoot the system and install or replace system

components. This document is available at

dell.com/support/manuals

.

Dell systems management application documentation provides information

about installing and using the systems management software. This document is

available online at

dell.com/support/manuals

.

NOTE:

Always check for updates on

dell.com/support/manuals

and read the

updates first because they often supersede information in other documents.

NOM Information (Mexico Only)

The following information is provided on the device described in this document

in compliance with the requirements of the official Mexican standards (NOM):

Importer Dell Inc. de México, S.A. de C.V.

Paseo de la Reforma 2620-11° Piso

Col. Lomas Atlas

11950 México, D.F.

Model number B08S

Supply voltage 100-240 V AC with 1200 W Power

Supply Unit

200-240 V AC with 1400 W Power

Getting Started With Your System | 12

Supply Unit

Frequency 50/60 Hz

Current consumption

12-8 Amps with 1200 W Power Supply

Unit

9 Amps with 1400 W Power Supply

Unit

Technical Specifications

Power

NOTE:

The system doesn’t support a mixed

installation of 1200 W and 1400 W power supply

units.

NOTE:

Both the 1200 W and 1400 W PSUs are hot swappable, and they can support hot swap in

any condition if the system has the power throttling feature.

AC power supply (per power supply)

Wattage

1200 W

Voltage 100-240 VAC, 50/60 Hz, maximum input

current: 12.0-8.0 Amps

NOTE:

For 1200 W power supply, output 1200 W is for

high line (input 200-240 VAC), output 1023 W is for low

line (input 100-120 VAC).

Heat dissipation

4016.251 BTU/hr maximum

Maximum inrush current Initial In-rush Current cannot exceed 55

Amps (peak). Secondary In-rush Current

cannot exceed 35 Amps (peak).

Wattage

1400 W

Voltage 200-240 VAC, 50-60 Hz, maximum input

current: 9.0 Amps

Heat dissipation

6024.376 BTU/hr maximum.

Maximum in-rush current Initial In-rush Current cannot exceed 55

Amps (peak). Secondary In-rush Current

cannot exceed 25 Amps (peak).

Getting Started With Your System | 13

Battery (per system board)

System battery

CR 2032 3.0-V lithium ion coin cell

Physical

Height

8.68 cm (3.42 in)

Width

44.8 cm (17.6 in)

Depth

79.0 cm (31.1 in)

Weight (maximum

41 kg (90.38 lb) (with 12*3.5” HDD)

configuration)

39 kg (86.00 lb) (with 24*2.

5” HDD)

Weight (empty) 15.7 kg (34.61 lb) (with 2.5” HDD bay)

15.1 kg (33.29 lb) (with 3.5” HDD bay)

Environmental

NOTE:

For additional information about environmental measurements for specific system

configurations, see

www.dell.com/environmental_datasheets

.

Temperature

Operating 10° to 35°C (50° to 95°F) with a maximum

temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1°F/550 ft.

CAUTION:

The maximum number of memory modules

and hard drives supported on 1U and 2U node

configurations, with 130W (4 and 8 core) and 135W

processors, depends on the power supply installed.

Storage 40° to 65°C (40° to 149°F) with a

maximum temperature gradation of 20°C per

hour

Operating 20% to 80% (noncondensing) with a maximum

humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Operating

0.26 Grms at 5350 Hz

Storage 1.88 Grms at 10500 Hz for 15 min

Getting Started With Your System | 14

Operating One shock pulse in the positive z axis

(one pulse on each side of the system) of 31 G

for 2.6 ms in the operational orientation

Storage Six consecutively executed shock pulses in the

positive and negative x, y, and z axes

(one pulse on each side of the system) of 71 G

for up to 2 ms;

Six consecutively executed shock pulses in the

positive and negative x, y, and z axes

(one pulse on each side of the system) of 27 G

faired square wave pulse with velocity change

at 235 inches/second (597 centimeters/second)

Operating

-15.2 to 3,048 m (-50 to 10,000 ft.)

Storage

-15.2 to 10,668 m (-50 to 35,000 ft.)

Class

G1 as defined by ISA-S71.04-1985

Аннотация для Dell PowerEdge C6220 II в формате PDF