Ariston CE6VP4: Installation

Installation: Ariston CE6VP4

Installation

Before operating your new appliance please read

The legs* fit into the slots on

this instruction booklet carefully. It contains important

the underside of the base of

GB

information concerning the safe installation and

the cooker.

operation of the appliance.

Please keep these operating instructions for future

reference. Make sure that the instructions are kept with

the appliance if it is sold, given away or moved.

The appliance must be installed by a qualified

professional in accordance with the instructions

Electrical connection

provided.

Fitting the power supply cable

To open the terminal board:

Any necessary adjustment or maintenance must be

Insert a screwdriver into the side tabs of the

performed after the cooker has been disconnected

terminal board cover.

from the electricity supply.

Pull the cover to

open it.

Positioning and levelling

It is possible to install the appliance alongside

cupboards whose height does not exceed that of the

hob surface.

Make sure that the wall in contact with the back of

the appliance is made from a non-flammable, heat-

resistant material (T 90°C).

To install the cable, follow the instructions below:

To install the appliance correctly:

Loosen the cable clamp screw and the wire contact

Place it in the kitchen, the dining room or the bed-

screws.

sit (not in the bathroom).

The jumpers are pre-set at the Factory for 230 V

If the top of the hob

single-phase connection (see figure).

is higher than the

HOOD

cupboards, the

230V ~

appliance must be

H05RR-F 3x4 CEI-UNEL 35363

Min. mm.

600

installed at least 600

mm.

NL

mm away from them.

420

420

If the cooker is

700 mm. without hood

Min.

Min. mm.

5

3

1

min. 650 mm. with hood

min.

installed underneath a

wall cabinet, there must

4

2

be a minimum distance

of 420 mm between this

cabinet and the top of the hob.

This distance should be increased to 700 mm if the

To carry out the electrical connections as shown in

wall cabinets are flammable (see figure).

the figures, use the two jumpers inside the box (see

Do not position blinds behind the cooker or less

figure - labelled P).

than 200 mm away from its sides.

P

Any hoods must be installed according to the

instructions listed in the relevant operating manual.

N

L1

Levelling

If it is necessary to level the

appliance, screw the

adjustable feet into the places

provided on each corner of the

base of the cooker (see figure).

L2

L3

*

Only available in certain models.

15

Once the appliance has been installed, the power

400V 2N~

GB

supply cable and the electrical socket must be easily

H05RR-F 4x4 CEI-UNEL 35363

accessible.

NL2L1

The cable must not be bent or compressed.

5

3

1

The cable must be checked regularly and

4

2

replaced by authorised technicians only.

The manu

facturer declines any liability should

these safety measures not be observed.

400V 3N~

H05RR-F 5x2.5 CEI-UNEL 35363

NL3L1L2

5

3

1

4

2

Secure the power supply cable by fastening the

cable clamp screw then put the cover back on.

Connecting the supply cable to the electricity

TABLE OF CHARACTERISTICS

mains

Oven dimensions

32x43.5x40 cm

(HxWxD)

Install a standardised plug corresponding to the load

Volume

56 l

indicated on the appliance data plate (see Technical

Useful measurements

width 42 cm

data table).

relating to the oven

depth 44 cm

The appliance must be directly connected to the

compartment

height 8.5 cm

mains using an omnipolar switch with a minimum

Voltage and frequency

see data plate

contact opening of 3 mm installed between the

Ceramic hob

appliance and the mains. The switch must be suitable

Front Left

1700 W

Back Left

1200 W

for the charge indicated and must comply with current

Back Right

2200 W

electrical regulations (the earthing wire must not be

Front Right

1200 W

interrupted by the switch). The supply cable must be

Max. ceramic hob

consumption

6300 W

positioned so that it does not come into contact with

Directive 2002/40/EC on the

temperatures higher than 50°C at any point.

label of electric ovens.

Standard EN 50304

Before connecting the appliance to the power supply,

Energy consumption for Natural

make sure that:

convection – heating mode:

The appliance is earthed and the plug is compliant with

ENERGY LABEL

Traditional mode

the law.

The socket can withstand the maximum power of

Declared energy consumption for

Forced convection Class –

the appliance, which is indicated by the data plate.

heating mode:

The voltage is in the range between the values

Baking.

indicated on the data plate.

This appliance conforms to the

The socket is compatible with the plug of the

following European Economic

Community directives:

appliance. If the socket is incompatible with the

2006/95/EEC dated 12/12/06

plug, ask an authorised technician to replace it. Do

(Low Voltage) and subsequent

not use extension cords or multiple sockets.

amendments - 89/336/EEC

dated 03/05/89 (Electromagnetic

Compatibility) and subsequent

amendments - 93/68/EEC dated

22/07/93 and subsequent

amendments. 2002/96/EC

16