Fagor CFB-90AX: Electrical connection

Electrical connection: Fagor CFB-90AX

Electrical connection

Installation wall model

The mains power supply must correspond to the rating

Fig. 5

indicated on the plate situated inside the hood. If provided with

1. Using a pencil, draw a line on the wall, extending up to

a plug connect the hood to a socket in compliance with current

the ceiling, to mark the centre. This will facilitate

regulations and positioned in an accessible area. If it not fitted

installation.

with a plug (direct mains connection) or if the plug is not

2. Rest the drilling template against the wall: the vertical

located in an accessible area apply a double poled switch in

centre line printed on the drilling template must

accordance with standards which assures the complete

correspond to the centre line drawn on the wall, and the

disconnection of the mains under conditions relating to over-

bottom edge of the drilling template must correspond to

current category III, in accordance with installation

the bottom edge of the hood.

instructions.

3. Place the lower support bracket on the perforation

Warning! Before re-connecting the hood circuit to the mains

diagram making it coincide with the traced triangle, mark

supply and checking the efficient function, always check that

the two external holes and perforate.

the mains cable is correctly assembled.

Note: Always make the holes indicated on the template.

The upper 2 are for hooking the hood up while the lower

Mounting

holes (generally 1 central or more lateral) are for the

Before beginning installation:

definitive and safety fixing.

Check that the product purchased is of a suitable size for

Remove the perforation diagram, insert the wall-dowels

the chosen installation area.

and fix the support bracket of the hood with two 5x45 mm

To facilitate installation, remove the fat filters and the

screws.

other parts allowed and described here, dismantle and

4. Apply the flues support bracket G to the wall adherent to

mount it.

the ceiling, use the flues support bracket as a perforation

To remove see also the relative paragraphs.

diagram (if present, the small slot on the support must

Remove the active carbon (*) filter/s if supplied (see also

coincide with the line drawn previously on the wall) and

relative paragraph). This/these is/are to be mounted only

mark two holes with a pencil. Make the holes (Ø8mm),

if you want lo use the hood in the filtering version.

and insert 2 dowels.

Check (for transport reasons) that there is no other

5. Fix the chimney support bracket to the wall using two

supplied material inside the hood (e.g. packets with

5x45mm screws.

screws (*), guarantees (*), etc.), eventually removing

6. Hang the hood onto the lower bracket.

them and keeping them.

7. Adjust the distance of the hood from the wall.

If possible, disconnect and move freestanding or slide-in

8. Adjust the horizontal position of the hood.

range from cabinet opening to provide easier access to

9. Fix the hood into its final position on the wall

rear wall/ceiling. Otherwise put a thick, protective

(ABSOLUTELY ESSENTIAL).

covering over countertop, cooktop or range to protect

10. Connect a pipe (pipe and pipe clamps not provided, to be

from damage and debris. Select a flat surface for

purchased separately) for discharge of fumes to the

assembling the unit. Cover that surface with a protective

connection ring located over the suction motor unit.

covering and place all canopy hood parts and hardware

If the hood is to be used in ducting version, the other end

in it.

of the pipe must be connected to a device expelling the

Disconnect the hood during electrical connection, by

fumes to the outside. If the hood is to be used in filter

turning the home mains switch off.

version, then fix the deflector F to the chimney support

In addition check whether near the installation area of the

bracket G and connect the other extremity of the pipe to

hood (in the area accessible also with the hood mounted)

the connection ring placed on the deflector F.

an electric socket is available and it is possible to

11. Connect the electricity.

connect a fumes discharge device to the outside (only

12. Apply the chimney stacks and fasten them at the top to

suction version).

the chimney support „G“ (12b) using 2 screws (12a)

Carry out all the masonry work necessary (e.g.

13. Slide the bottom section of the chimney down until it

installation of an electric socket and/or a hole for the

completely covers the suction unit and slots into the

passage of the discharge tube).

housing provided on top of the hood.

Expansion wall plugs are provided to secure the hood to most

Remount the carbon filter frame and the fat/s filter/s and check

types of walls/ceilings. However, a qualified technician must

the perfect functioning of the hood.

verify suitability of the materials in accordance with the type of

wall/ceiling. The wall/ceiling must be strong enough to take

At the end of the installation:

the weight of the hood. Do not tile, grout or silicone this

- select the hob (see related paragraph)

appliance to the wall. Surface mounting only.

- carry out automatic calibration (see related paragraph)

10