Fagor DH-20D: 4. CONTROL PANEL

4. CONTROL PANEL: Fagor DH-20D

background image

12

•   Unplug the appliance when not in use, 

before moving it, and before carrying out 

any cleaning or maintenance.

•   Never pull on the cable to remove the 

plug.

•   Do not place any heavy or hot objects 

on the appliance.

•   Do not allow children to handle or play 

with the appliance.

•   Do not push any objects through the 

air inlet/outlet grilles as this could be 

dangerous when the fan is running at 

high speed.

•   Do not cover the air inlet/outlet grilles.

•   Do not use the appliance in narrow, 

sealed rooms.

• This appliance should not be used 

by physically, sensorially or mentally 

handicapped people or people without 

experience or knowledge of it (including 

children), unless they are supervised or 

instructed in the use of the appliance by 

a person responsible for their safety.

•   Children should be watched to ensure 

they do not play with the appliance.

FOR CORRECT FUNCTIONING

IMPORTANT: Place the appliance on a 

flat, stable surface.

•   Close the doors and windows of the 

room in which the appliance is to be 

used.

•   The temperature in the room in which 

the appliance is to be used must 

be between 5ºC and 35ºC. If the 

temperature exceeds these limits the 

compressor will stop working.

•   If the ambient temperature is lower than 

5º C, the absolute humidity will be very 

low and it will therefore not be necessary 

to use the dehumidifier.

•   When the appliance stops, wait around 5 

minutes before starting it up again.

•   Do not place any objects or pour any 

liquids into the water tank.

4. CONTROL PANEL

Indicator lights

A.

 Power on indicator light (green)

B.

 Water tank full indicator light (red)

  Glows when the watertank is ready to 

be emptied, or when the watertank is 

removed or not replaced in the proper 

position.

NOTE:

 The water level control switch 

shuts off the dehumidifier when the 

watertank is full, or when the watertank 

is removed or not replaced in the proper 

position. When the setting humidity 

is reached, the unit will be shut off 

automatically.

  Wait 3 minutes before resuming operation

  After the unit has stopped, it can not be 

restart operation in the first 3 minutes. 

This is to protect the unit. Operation will 

automatically start after 3 minutes.

  When frost builds up on the evaporator 

coils, the compressor will cycle off and 

the fan will continue to run until the frost 

disappears.

C.

 Continuous operation on indicator light 

(green)

D.

 Display

  Shows the set % humidity level while 

setting, then shows the actual (±5 % 

accuracy) room % humidity level. 

Error codes:

E1.

  Humidity sensor error—Unplug the unit 

and plug it back in. If error repeats, call 

for service.

E2.

  Temperature sensor error—Unplug the 

unit and plug it back in. If error repeats, 

call for service

Protect codes:

P1.

 Unit is defrosting—Allow the unit to 

automatically defrost. The protect will 

clear after the unit self defrosts.

P2.

 Water tank is full or watertank is not in 

the right position—Empty the water tank 

and replace in the right position

5. FUNCTIONING

E   Power pad

Press to turn the dehumidifier on and 

off.

F   Humidity set control pads

The humidity level can be set within a 

range of 35% RH (Relative Humidity) 

Оглавление