Festool LEX 3 77-2-5: 9 Service and maintenance

Festool
LEX 3 77-2-5

9 Service and maintenance: Festool LEX 3 77-2-5

background image

LEX 3

17

GB

9 Service and maintenance

Customer service and repair

 only

through manufacturer or service

workshops: Please find the nearest

address at:

www.festool.com/Service

Use only original Festool spare parts!

Order No. at:

www.festool.com/Service

9.1

Vanes

We recommend replacing the vanes of the motor at

the following intervals:

– Lubricated operation: Approx. 2,000 h

– Non-lubricated operation: Approx. 500 h

9.2

Replacing the silencer

In order to maintain the power and performance of

the compressed air tool, replace the silencer on the

IAS hose systems at regular intervals.

9.3

Sanding pad brake

The rubber sleeve

[5-1]

 brushes off the sanding pad

and prevents uncontrolled turning of the sanding

pad. This must be replaced if the braking effect de-

creases.

9.4

Cleaning the extraction channels

We recommend cleaning the extraction channels in

the machine roughly once a week (particularly if

sanding synthetic resin, in the case of wet sanding

and if sanding plaster) 

[5-2]

using a small flat brush

or a cloth.

10 Accessories

The order numbers of the accessories and tools can

be found in the Festool catalogue or on the Internet

under "www.festool.com".

11 Environment

Do not dispose of the device together with domes-

tic waste!

 Dispose of machines, accessories and

packaging at an environmentally responsible recy-

cling centre. Observe the valid national regulations.

Information on REACh: 

www.festool.com/reach

12 EU Declaration of Conformity

We declare under sole responsibility that this prod-

uct complies with all the relevant requirements in

the following Directives, standards and normative

documents:

DIN EN ISO 11148-8 i.a.w. the provisions of 2006/

42/EC Directive.

Festool Group GmbH & Co. KG

Wertstr. 20, D-73240 Wendlingen, Germany

Dr. Martin Zimmer

Head of Research, Development and Technical

Documentation 

2013-06-20

WARNING

Risk of injury

The machine should always be disconnected

from the compresses air supply before any work

is carried out on the machine.

All maintenance and repair work which requires

the motor casing to be opened may only be car-

ried out by an authorised service centre.

EKAT

1

2

3

5

4

Compressed air eccentric sander

Serial no.

LEX 3 77/2,5

496675

LEX 3 125/3

496890

LEX 3 125/5

496891

LEX 3 150/3

496886

LEX 3 150/5

496887

Year of CE mark: 2012

LEX 3 150/7

496888

Year of CE mark: 2013

Оглавление