Fagor CFP-60AX: Operation

Operation: Fagor CFP-60AX

! Use a duct with an as smooth as possible inside.

Operation

! The duct must be made of certified material.

Use the high suction speed in cases of concentrated kitchen

vapours. It is recommended that the cooker hood suction is

switched on for 5 minutes prior to cooking and to leave in

Filter version

operation during cooking and for another 15 minutes

One active charcoal filter is needed for this and can be

approximately after terminating cooking.

obtained from your usual retailer.

The filter removes the grease and smells from the extracted

air before sending it back into the room through the upper

outlet grid.

The models with no suction motor only operate in ducting

mode, and must be connected to an external suction device

(not supplied).

The connecting instructions are supplied with the peripheral

suction unit.

a. ON/OFF light switch

b. Speed 1/OFF switch

Installation

c. 2-speed selection

The minimum distance between the supporting surface for the

d. 3-speed selection

cooking equipment on the hob and the lowest part of the

e. 4-speed selection

range hood must be not less than 50cm from electric cookers

and 65cm from gas or mixed cookers.

Troubleshooting

If the instructions for installation for the gas hob specify a

greater distance, this must be adhered to.

SYMPTOMS SOLUTIONS

The hood is not working... Ensure that:

Electrical connection

The power is not cut off.

The mains power supply must correspond to the rating

A speed has been selected.

indicated on the plate situated inside the hood. If provided with

The hood is not operating

Ensure that:

a plug connect the hood to a socket in compliance with current

effectively...

The selected motor speed is

regulations and positioned in an accessible area. If it not fitted

sufficient for the quantity of

with a plug (direct mains connection) or if the plug is not

smoke and vapours to be

located in an accessible area apply a double pole switch in

cleared.

accordance with standards which assures the complete

The kitchen is sufficiently

disconnection of the mains under conditions relating to over-

ventilated to allow for fresh

current category III, in accordance with installation

air intake.

instructions.

The air pipe circuit involves

Warning! Before re-connecting the hood circuit to the mains

a lack of efficiency of the

supply and checking the efficient function, always check that

cooker hoods. Contact a

the mains cable is correctly assembled.

qualified technician.

Warning! Power cable replacement must be undertaken by

The carbon filter is not worn

the authorised service assistance centre or similar qualified

(hood operating in recycling

person.

mode).

Mounting

The hood stopped

Ensure that:

Expansion wall plugs are provided to secure the hood to most

working

The power is not cut off.

types of walls/ceilings. However, a qualified technician must

The single-pole cut-off

verify suitability of the materials in accordance with the type of

device was not activated.

wall/ceiling. The wall/ceiling must be strong enough to take

the weight of the hood. Do not tile, grout or silicone this

appliance to the wall. Surface mounting only.

11