Hama EWS-880: g Operating Instruction
g Operating Instruction: Hama EWS-880
g Operating Instruction
hank you for your purchase of this delicate Radio
MAIN FEATURES
5. MEM/- key
TRANSMITTER:
Controlled weather station. The utmost care has
- In normal mode, press it to check the max./
gone into the design and manufacture of your
MAIN UNIT:
min. indoor and outdoor temperature record
clock. Please read the instructions carefully and
for 5 seconds.
keep the manual well for future reference.
- Press and hold it for 3 seconds to delete the
max./min. temperature record.
GETTING START
- In setting mode, press it to adjust the value
Before using the main unit and transmitter:
of the fl ashing digit downwards. And press it
1. Remove the battery door of the main unit and
without releasing to speed up the setting.
transmitter.
2. Install 2 new AA size batteries for both main
6. DISPLAY SET key
1. LED indicator
unit and transmitter, according to the polarity
- In normal mode, press and hold it for 3
- Flashes when the remote unit transmitting a
mark on the battery compartment.
seconds to enter time setting mode.
reading.
3. Replace the battery door.
- In time setting mode, press it to step the
4. After the batteries are installed, all LCD
1. LCD display
setting item, and press and hold it for 3
2. CHANNEL slide switch
segment will be shown.
- Display of the time, alarm time, outdoor &
seconds to save and exit the setting.
- Assign the transmitter to Channel 1, 2 or 3.
5. Press the “RESET” key of main unit fi rst, and
indoor temperature and weather forecast.
press the “RESET” key of transmitter.
7. °C/°F slide switch
3. RESET key
6. It will automatically receive 433 MHz signal
2. SNOOZE / LIGHT key
- Select temperature unit between °C/°F.
- Press it to reset the transmitter.
from transmitter for channel test in 8 seconds.
- Press it to turn on backlight for 5 seconds.
7. After 5 minutes channel test, it will turn to RC
- When the alarm is sounding, press it to stop
8. SENSOR key
4. Wall-mounting holder
signal reception automatically.
the current alarm and activate snooze.
- Press it to start 433 MHz channel test for main
- Use it to support the transmitter on the wall.
8. Radio Controlled function, the current time &
unit & transmitter.
date automatically synchronized with the time
3. ALARM SET key
- During the channel test, press and hold it for 3
5. Battery compartment
signal transmitted from Germany(DCF77).
- Press it to display alarm time for 5 seconds.
seconds to manual turn off.
During alarm time displayed, press it to turn
SIGNAL STRENGTH INDICATOR
Note:
on/ off alarm function.
9. RCC key
The signal indicator fl ashing means time signals
1. The unit can operate up to 3 remote
- Press and hold it for 3 seconds to enter alarm
- Press it to manual receive RC signal.
are being received. If the RC clock receives
transmitters.
setting mode.
- During the RC reception, press and hold it for 3
signal successfully, a sync-time symbol “
”
2. Position the unit and transmitter within the
- In alarm setting mode, press it to step the
seconds to turn off synchronisation.
appears on the LCD. The unit has already
effective transmission range: 50 meters in
setting item, and press it to save and exit the
received the time signal. Otherwise, the signal
usual circumstances.
setting.
10. RESET key
strength symbol will disappear from the LCD
3. In some cases, you may not receive the
- In case of mal-function, press it by using a
display.
signal immediately, you can reset the unit and
4. CH/+ key
metal wire to reset all the values.
transmitter again as described above.
- In normal mode, press it to select channel 1 to
Note:
channel 3.
11. Battery door
You may press “RCC” key to receive the time
- Press and hold it for 3 seconds to turn to
signal manually. The receive mode will be off
channel auto-change mode. Press it again to
automatically after 6-16 minutes. Receive mode
return to normal mode.
consumes more battery power that may reduce
- In setting mode, press it to adjust the value
battery lifetime.
of the fl ashing digit upwards. And press it
without releasing to speed up the setting.
8 9
00113985man_cs_de_el_en_es_fr_hu_it_nl_pt_ru_sk.indd 8-9 11.01.13 08:04
DAYLIGHT SAVING TIME(DST)
Note:
a). Auto-stop after two minutes alarming if
The clock has been programmed to automatically
If your local time is different from the RC received
without any operation and it will re-alarm by
switch when daylight saving time is in effect.
time, you can set the desired time zone.The
the next day.
Your clock will display “DST” on the LCD during
available time difference is from -23 hours to +23
b). By pressing “SNOOZE” key to enter snooze
the summer.
hours. After setting the desired time difference,
that the alarm will sound again after 5
Channel
1
Channel
2
Channel
3
the clock will show the time that RC received
minutes.
TIME AND CALENDAR SETTING
time plus/minus the time difference.
c). By pressing “ALARM SET” key to turn off the
If the clock does not receive the time signal
alarm function.
Note:
successfully, you can set the time manually. As
ALARM TIME SETTING
In channel auto-change mode, channels change
soon as the transmitter is received again, the
1. In normal mode, press and hold “ALARM SET”
Note:
automatically in every 4 second.
clock will automatically synchronize with the
key for 3 seconds until the Hour digit fl ashing.
1. The snooze could be used continuously in 24
received time.
2. Press “+” / “-” key to adjust the value of the
hours.
READING INDOOR&OUTOOR TEMPERATURE
1. In normal mode, press and hold “DISPLAY
fl ashing digit.
2. During the snooze, the alarm icon will keep
RECORDS
SET” key for 3 seconds until the Hour format
3. Press “ALARM SET” key again to step the
fl ashing.
1. Push “°C/°F” switch to change the
digit fl ashing.
setting value to Minute with the Minute digit
temperature unit to Celsius or Fahrenheit.
2. Press “+” / “-” key to select 12/24 hour format.
fl ashing.
ABOUT THE WEATHER INDICATOR
2. Press “CH/+” key to change the channels
3. Press “DISPLAY SET” key again to step
4. Press “+” / “-” key to adjust the value of the
The built-in barometer can notice atmosphere
among 3 channels and check their
the setting item to Hour with the Hour digit
fl ashing digit.
pressure changes. Based on the data collected,
temperature.
fl ashing.
5. Press “ALARM SET” key to save and exit the
it can predict the weather conditions in the
4. Press “+” / “-” key to adjust the value of the
setting.
forthcoming 12-24 hours.
Note:
fl ashing digit.
1. Once the channel is assigned to one
5. Do the above operation in this sequence: 12/24
transmitter, you can only change it by
Hr > Hour > Minute > Second > Time zone.
removing the batteries or resetting the unit.
6. Press and hold “” key for 3 seconds to save
Sunny Slight
Cloudy Rainny
2. If no signals are received or the transmission
and exit the setting.
cloudy
is interfered, “---” will appear on the LCD.
Alarm time mode Hour setting Minute setting
Note:
3. Relocate the clock or the transmitter in other
1. The accuracy of a general pressure-based
positions and make sure the transmission is
weather forecast is about 70% to 75%.
within the effective range of 50 meters approx.
Note:
2. The weather forecast is meant for the
4. After several trials in vain, please reset
1. In alarm mode, the “AL” icon will display on
forthcoming12-24 hours. It may not necessarily
the clock thoroughly. Try out where your
Normal mode 12/24 Hr setting
Hour setting
the LCD.
refl ect the current situation.
multifunctional alarm clock receives the
2. The alarm function will turn on automatically
signals best.
once you set the alarm time.
VIEW THE CHANNEL
1. The default displayed channel is channel 1.
CHECKING AND DELETING MAX./MIN.
USING ALARM AND SNOOZE FUNCTION
In normal mode, press “+CH” key to check
TEMPERATURE REOCRDS
1. Set the desired alarm time as described in the
the outdoor temperature from channel 1 to
1. Press “MEM/-” key to check and keep the
Minute setting
above section.
channel 3.
maximum / minimum temperature record for 5
2. Or press “ALARM SET” key to display the
2. Press and hold “+/CH” key for 3 seconds to
seconds.
alarm time, press it again to turn on alarm
turn to channel auto-change mode that the
2. Press and hold the “MEM/-” key for 3
function with the alarm icon “
” displayed on
channels change automatically.
seconds to delete the maximum and minimum
the LCD.
3. Press “+/CH” key again to return to normal
temperature records.
3. When clock reach the alarm time, alarm
mode.
sound will start. Where, it can be stopped by
Time zone
Second setting
following operation:
setting
10 11
00113985man_cs_de_el_en_es_fr_hu_it_nl_pt_ru_sk.indd 10-11 11.01.13 08:04
Note:
3. Avoid placing the unit on or next to metal
POWER
Once you reset or re-install batteries for the main
plate.
Main unit: 3V, use 2xAA 1.5V battery
unit, all the value will be defaulted.
4. Closed area such as airport, basement, tower
block or factory is not recommended.
Remote sensor: 3V, use 2xAA 1.5V battery
5. Do not start reception on a moving article such
as vehicle or train.
DIMENTION
Main unit: 84(W) x 141(H) x 47(D)mm
Current
Max. temperature Min.
temperature
temperature
Remote sensor: 65(W) x 100(H) x 35(D)mm
ICE ALERT
SPECIFICATION
1. When the outdoor temperature within the
range of -2°C~3°C (28°F~37°F), the Ice Alert
MAIN UNIT
icon “
” will display on LCD & fl ashing
Measurement range: -40.0~70.0°C
continuously.
(-40.0~158.0°F)
2. Ice Alert icon “
” will disappear when
outdoor temperature out of above temperature
Recommended operating range: 0~45.0°C
range.
(32.0~113.0°F)
Resolution: 0.1°C/°F
Radio Controlled signal: DCF77
REMOTE SENSOR
Measurement range: 40.0~70.0°C
BATTERY REPLACEMENT
(-40.0~158.0°F)
When the LCD becomes dim, replace with
2 AA size batteries at once; while if the low
Recommended operating range: 20.0~55.0°C
battery indicator “
” displays in the outdoor
(-4.0~131.0°F)
window, it indicates that the battery power of the
transmitter is not enough, and you should replace
Resolution: 0.1°C/°F
with 2 AA size batteries at once.
RF transmission frequency: 433 MHz
Note:
Attention! Please dispose of used unit
RF transmission range: Maximum 50 meters
or batteries in an ecologically safe
manner.
No. of remote sensor: Up to 3 units
SUGGESTION
Temperature sensing cycle:
1. Everyday the unit will automatically search for
Around 60~64seconds
the time signal at 2:00, 8:00, 14:00 and 20:00.
2. Always place the unit away from interfering
sources such as TV set, computer, etc.
12 13
Ice Alert icon
00113985man_cs_de_el_en_es_fr_hu_it_nl_pt_ru_sk.indd 12-13 11.01.13 08:04