Dell PowerVault NX3500: Power Physical Environmental
Power Physical Environmental: Dell PowerVault NX3500
Table of contents
- Notes, Cautions, Warnings, and Danger
- Installation and Configuration Unpacking the Solution Installing the Rails, the System, and the Backup Power Supply in a Rack
- Connecting the Battery in the BPS Power Module Removing the Power Module Front Cover
- Removing the Battery Rotating the Battery
- Reinserting the Battery
- Securing the Power Module Front Cover
- Inserting the Power Modules
- Cabling the Solution
- Connecting the Power Cable(s)
- Securing the Power Cable(s)
- Turning On the Solution Installing the Optional Bezel
- Other Information You May Need
- Obtaining Technical Assistance NOM Information (Mexico Only) Technical Specifications PowerVault NX3500 System Specifications Processor Expansion Bus
- Memory Drives Connectors Video
- Power Physical Environmental
- Environmental (continued) Backup Power Supply Specifications BPS Model List
- Physical (120 V and 230 V Models) Electrical Input Electrical Output
- Electrical Output (continued) Environmental and Safety
- Environmental and Safety (continued) Battery (120 V and 230 V Models)

Power
AC power supply (per power supply)
Wa tt ag e
400 W
Voltage
100–240 VAC, 50/60 Hz
Heat dissipation
1666 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 25 A per power supply for
10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium coin cell
Physical
Height 4.29 cm (1.69 in)
Width 43.4 cm (17.09 in)
Depth 61.26 cm (24.12 in)
Weight (maximum configuration) 15 kg (33.02 lbs)
Weight (empty configuration) 5.96 kg (13.12 lbs)
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Tem perat ure
Operating
10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
Storage
–40 °C to 65 °C (–40 °F to 149 °F) with
a maximum temperature gradation of
20 °C per hour