Dell PowerEdge C6105: Physical Environmental

Physical Environmental: Dell PowerEdge C6105

background image

Getting Started With Your System          |          13

Maximum inrush current 

Initial In-rush Current cannot exceed 55 

Amps (peak). Secondary In-rush Current 

cannot exceed 35 Amps (peak). 

Battery (per system board)

System battery

CR 2032 3.0-V lithium ion coin cell 

RAID battery (optional) 

3.7-V lithium ion battery pack 

Physical 

Height 

8.76 cm (3.45 in) 

Width 

44.8 cm (17.6 in) 

Depth 

75.1 cm (29.47 in) 

Weight (maximum 

configuration) 

33.67 kg (74.2 lb) 

Weight (empty) 

15.11 kg (33.32 lb) 

Environmental 

NOTE: 

For additional information about environmental measurements for specific system 

configurations, see 

www.dell.com/environmental_datasheets

Temperature

Operating 

10° to 35°C (50° to 95°F) with a maximum 

temperature gradation of 10°C per hour 

NOTE:

 For altitudes above 2950 feet, the maximum 

operating temperature is derated 1°F/550 ft.

Storage 

–40° to 65°C (–40° to 149°F) with a 

maximum temperature gradation of 20°C per 

hour 

Relative humidity

Operating 

20% to 80% (noncondensing) with a 

maximum humidity gradation of 10% per 

hour 

Storage 

5% to 90% (noncondensing) 

Maximum vibration

Operating 

0.26 Grms at 5–350 Hz 

Storage 

1.93 Grms at 10–500 Hz for 15 min