Dell PowerEdge R515: Environmental

Environmental: Dell PowerEdge R515

background image

12

Getting Started With Your System

Environmental

NOTE: 

For additional information about environmental measurements for specific 

system configurations, see 

www.dell.com/environmental_datasheets

.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum 

temperature gradation of 10°C per hour

NOTE: 

For altitudes above 2950 feet, 

the maximum operating temperature is 

derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a 

maximum temperature gradation 

of 20°C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with 

a maximum humidity gradation 

of 10% per hour

Storage

5% to 95%, maximum humidity gradation 

of 10% per hour.

Maximum vibration

Operating

0.26 G at 5–350 Hz for 15 min

Storage

1.87 G at 10–500 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis 

(one pulse on each side of the system) of 

31 G for 2.6 ms in the operational orientation

Storage

Six consecutively executed shock pulses in 

the positive and negative x, y, and z axes 

(one pulse on each side of the system) 

of 71 G for up to 2 ms, and Square Wave 

32G, 270in/sec