Beurer BM 65: Advice on use
Advice on use: Beurer BM 65
Table of contents
- 2. Important information Signs and symbols 1. Getting to know your instrument
- Advice on use
- Storage and Care Advice on batteries
- 3. Unit description Repair and disposal
- Icons in the display: System requirements for the Beurer “Health Manager” computer software 1. Supported operating systems: 2. Supported architectures: 3. Hardware requirements:
- 4. Prepare measurement Setting date and time Inserting battery Operation with the mains part
- 5. Measuring blood pressure Positioning cuff
- Correct posture Measuring blood pressure
- 6. Evaluating results Cardiac arrhythmia: WHO classification: Range of blood pressure values Systolic
- 8. Error messages/trouble-shooting 7. Saving, retrieving and deleting results
- 10. Specifications Technical alarm – description 9. Cleaning and storing the instrument
- Technical information is subject to change without notifica- tion to allow for updates.
- 11. Adapter

Disposal in accordance with EC Directive
2002/96/EC – WEEE (Waste Electrical and
Electronic Equipment).
Manufacturer
17
Storage
•
If you want to perform several measurements on the same
person, wait five minutes between each measurement.
•
Do not take a measurement within 30 minutes after eat-
ing, drinking, smoking or exercising.
•
Repeat the measurement if you are unsure of the meas-
ured value.
•
The measurements taken by you are for your information
Permissible storage temperature and
55°C
only – they are not a substitute for a medical examination!
-20°C
humidity
RH ≤90%
Discuss the measurements with your doctor, and never
Operating
Permissible operating temperature and
base any medical decisions on them (e.g. medicines and
40°C
humidity
their administration)!
10°C
RH ≤90%
•
Do not use the blood pressure monitor on newborns,
Keep dry
pregnant women or patients with preeclampsia.
•
Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
SN Serial number
curacy. The same also applies to very low blood pressure,
diabetes, circulatory disorders and arrhythmias as well as
The CE labelling certifies that the product
chills or shaking.
complies with the essential requirements
•
The blood pressure monitor must not be used in connec-
0483
of Directive 93/42/EEC on medical prod-
tion with a high-frequency surgical unit.
ucts.
•
Only use the device on people who have the specified up-
per arm measurement for the device.
Advice on use
•
Please note that when inflating, the functions of the limb
•
In order to ensure comparable values, always measure
in question may be impaired.
your blood pressure at the same time of day.
•
Before every measurement, relax for about five minutes.