Heat dissipation

1571 BTU/hr maximum (non-redundant 

power supply)

1666 BTU/hr maximum (redundant 

power supply)

Maximum inrush current

Under typical line conditions and over the entire 

system ambient operating range, the inrush 

current may reach 25 A per power supply for 

10 ms or less

Batteries

System battery

CR 2032 3.0-V lithium coin cell

Physical

Height

4.29 cm (1.69 in)

Width

43.4 cm (17.09 in)

Depth

61.26 cm (24.12 in)

Weight (maximum configuration) 15 kg (33.02 lbs)

Weight (empty configuration)

5.96 kg (13.12 lbs)

Environmental

NOTE: 

For additional information about environmental measurements for specific 

system configurations, see 

www.dell.com/environmental_datasheets

.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum 

temperature gradation of 10°C per hour

NOTE: 

For altitudes above 2950 feet, the maximum 

operating temperature is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum 

temperature gradation of 20°C per hour

Relative humidity

Operating

8% to 85% (noncondensing) with a maximum 

humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)