Beurer BM 85: Notes on use
Notes on use: Beurer BM 85
Table of contents
- 1. Getting to know your instrument 2. Important notes Signs and symbols
- Notes on use
- Notes on batteries Instructions for repairs and disposal Instructions for storage and maintenance
- 3. Unit description
- Information on the display: USB interface System requirements for the Beurer “HealthManager” PC software.
- 4. Preparing for the measurement Press and hold the START/STOP button
- 5. Measuring blood pressure Attaching the cuff
- Performing the blood pressure measurement Adopting the correct posture
- 6. Evaluating results Cardiac arrhythmia: WHO classification:
- Resting indicator measurement (using HSD diagnostics) GREEN: haemodynamically stable RED: lack of haemodynamic stability
- 7. Displaying and deleting measurements
- Average values Individual measured values Deleting measured values
- 8. Transferring measurements Transfers using the USB interface
- 9. Cleaning and storing the unit 0. Error messages/trouble-shooting 11. Battery
- 12. Technical specifications
- Technical information is subject to change without notification 3. Mains part to allow for updates.

Application part, type BF
Direct current
Disposal in accordance with EC Directive
WEEE (Waste Electrical and Electronic
Equipment)
Manufacturer
20
Storage
•
If you want to perform several measurements on the same
person, wait five minutes between each measurement.
•
Do not take a measurement within 30 minutes of eating,
drinking, smoking or exercising.
•
Repeat the measurement if you are unsure of the measured
value.
•
The measurements taken by you are for your information
only – they are no substitute for a medical examination!
Discuss the measurements with your doctor and never base
any medical decisions on them (e.g. medicines and their
administration)!
Permissible storage temperature and humi-
55°C
•
Do not use the blood pressure monitor on newborns or
dity
-20°C
RH ≤90%
patients with preeclampsia. We recommend consulting a
doctor before using the blood pressure monitor during preg-
Operating
Permissible operating temperature and
40°C
nancy.
humidity
10°C
RH ≤90%
•
Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
Protect from moisture
curacy. The same also applies to very low blood pressure,
diabetes, circulatory disorders and arrhythmias as well as
SN Serial number
chills or shaking.
•
The blood pressure monitor must not be used in connection
The CE labelling certifies that the product
with a high-frequency surgical unit.
complies with the essential requirements of
•
Only use the unit on people that have the specified upper
Directive 93/42/EEC on medical products.
arm measurement for the unit.
•
Please note that when inflating, the functions of the limb in
Notes on use
question may be impaired.
•
During the blood pressure measurement, the blood circula-
•
In order to ensure comparable values, always measure your
tion must not be stopped for an unnecessarily long time. If
blood pressure at the same time of day.
the device malfunctions remove the cuff from the arm.
•
Before every measurement, relax for about five minutes.