Beurer BM 85: 12. Technical specifications
12. Technical specifications: Beurer BM 85
Table of contents
- 1. Getting to know your instrument 2. Important notes Signs and symbols
- Notes on use
- Notes on batteries Instructions for repairs and disposal Instructions for storage and maintenance
- 3. Unit description
- Information on the display: USB interface System requirements for the Beurer “HealthManager” PC software.
- 4. Preparing for the measurement Press and hold the START/STOP button
- 5. Measuring blood pressure Attaching the cuff
- Performing the blood pressure measurement Adopting the correct posture
- 6. Evaluating results Cardiac arrhythmia: WHO classification:
- Resting indicator measurement (using HSD diagnostics) GREEN: haemodynamically stable RED: lack of haemodynamic stability
- 7. Displaying and deleting measurements
- Average values Individual measured values Deleting measured values
- 8. Transferring measurements Transfers using the USB interface
- 9. Cleaning and storing the unit 0. Error messages/trouble-shooting 11. Battery
- 12. Technical specifications
- Technical information is subject to change without notification 3. Mains part to allow for updates.

< 25%
Cuff size 22 to 36 cm
Permissible operating
+ 10 °C to + 40 °C, ≤ 90 % relative humi-
You can take a maximum of 10 measurements
conditions
dity (non-condensing)
(flashes)
Permissible storage
-20 °C to + 55 °C, ≤ 90 % relative humi-
®
conditions
dity, 800 –1050 hPa ambient pressure
The Bluetooth
word mark and logos are registered trademarks
®
owned by Bluetooth
SIG, Inc. and any use of such marks by
Power supply DC 5 V
600mA lithium ion battery
Beurer GmbH is under license. Other trademarks and trade
3.7 V/400mAh
names are those of their respective owners.
Battery life For approx. 50 measurements, depen-
ding on levels of blood pressure and
12. Technical specifications
pump pressure
Model no. BM 85
Accessories Cuff, cuff holder, instructions for use,
Measurement me-
Oscillometric, non-invasive blood pres-
USB mains part, USB cable, storage
thod
sure measurement on the upper arm
pouch
Measurement range Cuff pressure 0 – 300 mmHg,
Classification Internal supply, IPX0, no AP or APG,
systolic 60 – 260 mmHg,
continuous operation, application part
diastolic 40 – 199 mmHg,
type BF
pulse 40 –180 beats /minute
Data transfer via
The blood pressure monitor uses Blue-
Display accuracy Systolic ± 3 mmHg,
Bluetooth® wireless
tooth® Smart (low energy),
diastolic ± 3 mmHg,
technology
2.4 GHz frequency band,
pulse ± 5 % of the value shown
Compatible with Bluetooth 4.0 smart-
phones/tablets
Measurement inac-
Max. permissible standard deviation
curacy
according to clinical testing:
List of supported smartphones/tablets
systolic 8 mmHg /
diastolic 8 mmHg
Memory 2 x 60 memory spaces
Dimensions L 180 mm x W 99 mm x H 40 mm
Weight Approximately 317 g (without cuff)
33