Setting the time (CLOCK)
NOTE
►
The time and programmed settings must be reset
after the batteries are changed.
u
Set the time according to the chapter entitled “Changing
the settings”.
u
Set the minutes by pressing the “+/
” [7] or “-” [16]
buttons, then press the SET button [8].
u
Set the hour by pressing the “+/
” [7] or “-” [16]
buttons.
u
Press the MODE button. The time display flashes
several times in quick succession. The time is shown
in the display [1].
Setting the unit of measurement (UNIT)
You can switch between the units “‰ BAC” (BAC = blood
alcohol content) and “mg/l”.
u
Set the unit of measurement according to the chapter
entitled “Changing the settings”.
u
Press the “+/” [7] or “-” [16] button to select the
appropriate unit of measurement. This unit is then
shown on the display [2 or 10].
u
Press the SET button [8] to save the setting. The
display flashes several times in quick succession and
the device exits the settings mode.
36
MW-1002
00087697bda_neu.indd 3600087697bda_neu.indd 36 03.08.2009 9:58:10 Uhr03.08.2009 9:58:10 Uhr

Cleaning the device (CLEAN)
GB
NOTE
►
To achieve a precise reading, make sure that there
is no leftover alcohol in the measuring chamber
prior to each alcohol test.
u
Start the cleaning process according to the chapter
entitled “Changing the settings”.
u
Press the “+/
” button [7] to start the cleaning process.
ON is shown in the display [1], followed by a countdown
from CL08 to CL00. OFF is displayed when the cleaning
process is finished.
u
Press the SET button [8]. The time is shown in the
display [1].
MW-1002
37
00087697bda_neu.indd 3700087697bda_neu.indd 37 03.08.2009 9:58:12 Uhr03.08.2009 9:58:12 Uhr

d
Bedienungsanleitung
GB
Automatic sensor cleaning (ASC)
NOTE
►
Perform the automatic sensor cleaning:
–
before the device is used for the first time and
–
if the device has not been used for a long
period of time (at least a week).
u
Remove the cleaning cap from the bracket .
u
Apply approx. 3-4 drops of alcohol to the cleaning cap
and insert it into the cleaning opening
.
38
MW-1002
00087697bda_neu.indd 3800087697bda_neu.indd 38 03.08.2009 9:58:14 Uhr03.08.2009 9:58:14 Uhr

GB
CAUTION
The sensor may be damaged if the alcohol
concentration is too high.
Using alcohol with a high concentration may cause
damage to the sensor.
Always use alcohol with a concentration of 3-5%.►
u
Start the sensor cleaning process according to the
chapter entitled “Changing the settings”.
u
If OFF appears in the display, press the “+/ ” button [7].
ON appears in the display.
u
Press the SET [8] button to activate the selected
cleaning process.
The cleaning process should stop automatically after 10
minutes. ASC flashes on the display throughout the entire
cleaning process [1]. The device beeps three times two
minutes before the end of the cleaning process. After the
cleaning process is complete, the device beeps once and
the time is shown in the display.
NOTE
►
The cleaning process can be cancelled at any time
by pressing the MODE button once.
MW-1002
39
00087697bda_neu.indd 3900087697bda_neu.indd 39 03.08.2009 9:58:15 Uhr03.08.2009 9:58:15 Uhr

d
Bedienungsanleitung
u
Loosen the cleaning cap an insert the cleaning cap into
GB
the bracket.
u
Start the device’s self cleaning process (see chapter
“Cleaning the device”).
Performing an alcohol test
NOTE
►
The test cannot provide accurate results unless
you have not smoked or consumed alcohol for at
least 20 minutes prior to testing.
u
Rinse your mouth thoroughly with water. Slide the faceplate
upwards and place one of the plastic tubes (included) onto
the mouth piece [9].
The device beeps once, PH flashes multiple times in the display
[1] and a countdown from PH19 to PH00 is displayed.
After the countdown is complete, the device beeps and BLOW
and READY flash in the display.
u
Blow into the plastic tube for approx. 6 seconds. The device
beeps and the measured value is displayed along with an
alarm message, if necessary (see chapter “Evaluating the
alcohol test”).
40
MW-1002
00087697bda_neu.indd 4000087697bda_neu.indd 40 03.08.2009 9:58:17 Uhr03.08.2009 9:58:17 Uhr

GB
NOTE
►
If the device does not detect a breath sample within
5 seconds after the countdown is complete, it beeps
for an additional 10 seconds. In order to perform
the alcohol test, you must press the SET button [8]
while blowing into the device.
►
If the device still does not detect a breath sample,
ERROR [15] and ERR appear in the display (1) and
the device beeps several times. Restart the alcohol
test by pressing the SET button [8] or by sliding the
faceplate down and back up again.
The device automatically initiates the cleaning process after
each test.
u
Press the SET button [8] if you wish to perform another
test.
u
Remove the plastic tube from the mouth piece and slide
the faceplate downwards in order to end the alcohol
test.
u
Clean the used plastic tube.
MW-1002
41
00087697bda_neu.indd 4100087697bda_neu.indd 41 03.08.2009 9:58:18 Uhr03.08.2009 9:58:18 Uhr

d
Bedienungsanleitung
GB
Evaluating the alcohol test
NOTE
Test results may vary if the user has diabetes.■
■ The measured value is
Measured value
smaller than 0.2‰ BAC
displayed. The backlight
colour is orange.
■ Warning level
Measured value
between 0.3 and 0.5‰
The device beeps 4 times
and the “Do not drive” symbol
[13] flashes 4 times. The
backlight colour alternates
between orange and red. The
measured value is displayed.
■
Measured value
Alarm level
between 0.5 and 1.7‰
The device beeps. The “Do
not drive” symbol flashes for
15 seconds and the backlight
colour alternates between
orange and red. Afterwards,
the symbol is displayed
continuously. The measured
value is displayed.
42
MW-1002
00087697bda_neu.indd 4200087697bda_neu.indd 42 03.08.2009 9:58:20 Uhr03.08.2009 9:58:20 Uhr

GB
■ HI is displayed in place of
Measured value larger
than 1.7‰ BAC
the measured value. See
“Alarm level” for additional
indicators.
Cleaning and care
Safety instructions
WARNING
Danger due to leaking battery acid!
Leaking battery acid can cause injuries (skin irritation)
and damage to the device.
Wash your hands thoroughly after use.►
Cleaning
■
Clean the device with a damp cloth and a mild cleaning
agent only.
■
Clean the used plastic tubes using a mild cleaning
agent.
MW-1002
43
00087697bda_neu.indd 4300087697bda_neu.indd 43 03.08.2009 9:58:21 Uhr03.08.2009 9:58:21 Uhr
Оглавление
- d Bedienungsanleitung
- g User manual
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- f d Mode d‘emploi Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- q d Instrukcja obsługi Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- c d Návod k použití Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- v d Návod na použitie Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- u d Руководство по эксплуатации Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung
- d Bedienungsanleitung