Dell PowerVault DL2200 CommVault: Power Physical Environmental
Power Physical Environmental: Dell PowerVault DL2200 CommVault
Table of contents
- Notes, Cautions, and Warnings
- Installation and Configuration Unpacking the System
- Optional – Connecting the Keyboard, Mouse, and Monitor Connecting the Power Cable(s)
- Securing the Power Cable(s) Turning On the System
- Installing the Optional Bezel Operating System Information Supported Operating System
- Other Information You May Need Obtaining Technical Assistance
- NOM Information (Mexico Only) Technical Specifications Processor Expansion Bus Memory
- Memory (continued) Drives Connectors Video
- Power Physical Environmental
- Environmental (continued)

Power
AC power supply (per power supply)
Wa tt ag e
750 W (redundant power supply)
Voltage
100–240 VAC, autoranging, 50–60 Hz
Heat dissipation
2450 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less
Batteries
System battery
CR 2032 3.0-V lithium coin cell
Physical
Height 8.67 cm (3.42")
Width 44.52 cm (17.53")
Depth 66.46 cm (26.17")
Weight (maximum configuration) 29.0 kg (63.8 lbs)
Weight (empty) 15.85 kg (34.87 lbs)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation
of 20°C per hour
10 Getting Started With Your System