Interconnectable Optical Smoke Alarm

ENGLISH
Table of contents
• Introduction 2
• Safety precautions 2
• Packaging content 2
• Technical specications 3
• Product and user description 3
• Installation instructions 6
• Maintenance 8
• Warranty 8
• Disclaimer 8
• Disposal 8
Introduction
This battery operated optical smoke alarm sends out a signal through radio
frequency to activate other installed SAS‑SA200/2002’s in case smoke is detected.
When installing multiple SAS‑SA200/2002’s, the smoke alarm that detects smoke will
automatically activate all other SAS‑SA200/2002’s to give an early warning audible
alarm. This provides extra time to leave the house. Equipped with a learn button and
a test button for periodic testing.
A smoke alarm has a limited life and should always be replaced 10 years after the
date of purchase. Write the purchase date on this manual for future reference.
The smoke alarm complies with the EN14604 standard of the Construction Products
Directive.
• We recommend that you read this manual before you install the smoke alarm
• Keep this manual in a safe place for future reference
Safety precautions
Do not expose the product to water or moisture
Do not paint over the smoke alarm
Packaging content
• 1x Smoke alarm
• 1x 9 V battery
• 3x 1.5 V AA batteries
• 1x Mounting material
• 1x Manual
2

ENGLISH
Technical specications
• Radio frequency: 433.92 MHz
• Battery: 1x 9 V DC, 3x 1.5 V AA
• Alarm: > 85 db (3 m)
• Maximum number to connect: unlimited
• Maximum range: 40 metres
• Test button: yes
• Learn button: yes
• Low battery alert: yes
• Operating temperature: ‑10 °C ~ + 40 °C
Product and user description
1. ALARM indicator
2. TEST button
Testing the smoke alarm
Like any other electronic device, smoke alarms are not foolproof. Smoke alarms
contain electronic components that can fail or wear out at any time.
We recommended that you test the smoke alarm every week to make sure it is
working properly.
Push and hold the test button until the alarm sounds for a few seconds. The
(red) alarm indicator (1) and (green) learn indicator (4) will ash for a moment.
If the alarm does not sound, check if the battery indicator ashes once every
45 seconds. If this is not the case and testing fails, please replace the batteries
immediately.
3

ENGLISH
Battery indicator
The battery indicator ashes every 45 seconds to show that the smoke alarm is
working properly. When the battery indicator ashes and gives a short beeping
sound, it indicates that the battery has a low capacity and should be replaced
immediately.
3. LEARN button
Follow the next steps to set the MAIN smoke alarm and ASSISTANT smoke
alarm(s) to create a smoke alarm system with 2 or more SAS‑SA200/2002’s.
1. Press the LEARN button two times. The LEARN indicator turns from red to
green. This smoke alarm will be the MAIN smoke alarm. Ensure the LEARN
indicator is green before proceeding.
2. Press the LEARN button of the ASSISTANT smoke alarm(s) once. The ALARM
indicator(s) turns on red. Ensure the ALARM indicator(s) are red before
proceeding.
3. Press the TEST button of the MAIN smoke alarm for several seconds in order
to send out the learn signal to the ASSISTANT smoke alarm(s). The ALARM
indicator ashes and the smoke alarm sounds. The ASSISTANT smoke
alarm(s) receive the signal and sounds.
4. Press the TEST button on each ASSISTANT smoke alarm(s) for several
seconds in order to send out the learn signal to the MAIN smoke alarm. The
MAIN smoke alarm receives the signal and sounds.
Note: the number of smoke alarms is unlimited. The maximum range between
2smoke alarms to communicate with each other is 40 metres.
4. LEARN indicator
5. Mounting plate and holes
Use the supplied screws and plugs to mount the mounting plate to the ceiling.
6. Remove the mounting place
Turn the mounting plate of the smoke
alarm counter clockwise to get access to
the battery compartment of the smoke
alarm.
4

ENGLISH
7. Battery compartment 9 V battery
8. Battery compartment 1.5 V AA battery
9. Safety catch
The safety catch prevents installing the
smoke alarm on the mounting plate
without inserting the battery rst. Note:
push the safety catch of the 1.5 V AA
battery into the battery compartment
when placing the batteries.
10. Placing the 9 V battery
Take o the plastic seal of the 9 V battery
and place the 9 V battery in the battery
compartment. Conform to the polarity
markings inside the battery compartment.
11. Placing the 1.5 V AA batteries
Take o the plastic seal of the 1.5 V AA
batteries and place the 1.5 V AA batteries
in the battery compartment. Place the
1.5V AA batteries conforming to the
polarity markings inside the battery
compartment.
5

ENGLISH
After placing the battery, use the test button to see if the smoke alarm works
properly.
(See Testing the smoke alarm.)
When the mounting plate is mounted on the ceiling and the smoke alarm is tested
after inserting the batteries, place the smoke alarm on the mounting plate by
turning it clockwise.
See the following chapter for where to mount the smoke alarm(s).
Installation instructions
Install a smoke alarm in every room or area on every level of the home.
Smoke may not reach the smoke alarm if it’s installed in only one room or area. If a
re starts in another room or area to where the smoke alarm is installed, the smoke
alarm will not detect the smoke, or will detect it too late to alert the household
members. A smoke alarm will not promptly detect a re except in the room or area
in which it is installed.
Place at least one smoke alarm in every room/area between the bedroom and the
exit of the house.
We recommended that you make an emergency escape plan, and practice this with
the members of your household, in case of an emergency.
The requirements for the installation of the smoke alarm may dier slightly by
region. Please contact your local authorities for any additional requirements.
Example installation of smoke alarms:
Loft
Bedroom
Hallway
Bedroom
Hallway
Kitchen
Hallway
Basement
Hallway
Living room
6

ENGLISH
On ceilings
Install smoke alarms as close to the centre of
ceiling mounting
minimum 30/50 cm
the ceiling as possible. If this is not possible,
install the smoke alarm at least 30 to 50 cm
from the wall.
(Due to dead air spaces)
Rooms with a gabled ceiling
Install the smoke alarm 90 cm from the
Minimum 90 cm
highest point.
(Due to dead air spaces)
Note: when installing a smoke alarm in a hallway that is 7.5 metres or longer, we
recommended that you install a smoke alarm at the beginning and at the end of the
hallway.
Do not install a smoke alarm
‑ In a humid, dusty and smoky environment
‑ In rooms or areas where temperatures are below 4 °C or above 38 °C
‑ In the kitchen, bathroom or garage
‑ In drafty places
‑ Near a fan or air vent
‑ Above heating
Note: when installing a smoke alarm in a hallway that is 7.5 metres or longer, we
recommended that you install a smoke alarm at the beginning and at the end of the
hallway.
7

ENGLISH
Maintenance
We recommended that you clean the smoke alarm once a month. Gently vacuum the outside of the smoke alarm with the
soft brush attachment of the vacuum cleaner. Do not use water, cleaning solvents or abrasives.
Warranty
No guarantee or liability can be accepted for any changes and modications of the product or damage caused due to
incorrect use of this product.
Disclaimer
Designs and specications are subject to change without prior notice. All logos, brands and product names are trademarks
or registered trademarks of their respective holders and are hereby recognised as such.
Disposal
• This product is designated for separate collection at an appropriate collection point.
Do not dispose of this product with household waste.
• For more information, contact the retailer or the local authority responsible for waste management.
This product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all
member states of the European Union. It also complies to all applicable specications and regulations in the country of sales.
Formal documentation is available upon request. This includes, but is not limited to: Declaration of Conformity (and product
identity), Material Safety Data Sheet, product test report.
Please contact our customer service desk for support:
via website: http://www.nedis.com/en‑us/contact/contact‑form.htm
via e‑mail: service@nedis.com
via telephone: +31 (0)73‑5993965 (during oce hours)
NEDIS B.V., De Tweeling 28, 5215 MC ’s-Hertogenbosch, THE NETHERLANDS
Intended re safety and installed in buildings
Essential characteristic 1: Pass
Essential characteristic 2: Pass
13
Essential characteristic 3: Pass
Model: LM‑101LG
Essential characteristic 4: Pass
DoP: 201308060001
Essential characteristic 5: Pass
0832‑CPR‑FR0033
Essential characteristic 6: Pass
EN 14604:2005/AC:2008
Essential characteristic 7: Pass
Smoke alarm devices
Essential characteristic 8: Pass
8