INFRA-RED EAR THERMOMETER

ENGLISH
Please read the instruction carefully before use
The ear thermometer is a device capable of achieving infra-red temperature
measurement when placed in the auditory canal of a subject. It is a safe mean
of measuring the human core body temperature through the ear.
Specication:
The standard we adopted is EN12470-5:2003 Clinical thermometers – Part 5:
Performance of infra-red ear thermometers (with maximum device).
This device complies with the requirements of IEC60601-1:1998, and
IEC60601-1-2:2001.
Range of displayed temperature : 34.0 °C~44.0 °C (93.2 °F~111.2 °F)
Display L (L) when the temperature is under 34.0 °C (93.2 °F)
Display H (H) when the temperature is over 44.0 °C (111.2 °F)
Operating environment:
Probe lens
Temperature: 16 °C~35 °C
(60.8°F~95.0°F)
Scan button
Humidity: ≤ 80% RH
Storage and transport conditions:
On/recall button
Temperature: -25 °C~55 °C (-13 °F~131 °F)
Humidity: ≤ 85% RH
Temperature scale: 0.1 °C (0.1 °F)
Battery cover
LCD
Accuracy: ± 0.2 °C (35.5 °C~42.0 °C)
± 0.4 °F (95.9 °F~107.6 °F)
Display: LCD, 3½ digits
Temperature value: display the maximum temperature in measuring
process
Temperature unit: °C or °F
Memory: last 10 measurements
Low voltage warning: the LCD display shows and then a beep sound is
made
Battery: 1x 3 V lithium battery (CR2032)
Dimensions: 110 x 35 x 35 mm
Net weight: Approx. 37 g
2

ENGLISH
Beeper sign: on/o, measuring nish and low voltage warning, etc.
Self-testing sequence: Press the on/recall button to turn on the thermometer
and all of symbol (See Fig. A) should be displayed on
the LCD in one second
Cautions
1. Before measuring, the thermometer must be stabilized for at least 30 min.
under operating conditions.
2. Please keep your ear canal clear, if not, the measuring result can be
inaccurate.
3. The symbol “?” on the LCD shows you can start the measurement.
4. Please don’t scratch the probe membrane, if you do, the thermometer loses
its accuracy or can be broken completely.
5. If the thermometer does not respond when you press any button, please
take out and replace the batteries.
6. Please don’t use the thermometer if you have any symptons related to
otitis.
7. Type B
equipment.
How to use
Measuring human core body temperature in the ear.
1. Press the on/recall button to turn on the
thermometer, a beep sound is heard and
the LCD displays as Fig. A within one
Fig. A
Fig. B
second. When the LCD displays as Fig. B,
you can start the measurement.
2. Straighten the ear canal by pulling the
outer ear up and back. (Caution: Many
pediatricians suggest to limit the use
of ear thermometers to children aged
Newborn-1 year 1 year-adult
under 6 months)
3. While pulling the outer ear, insert the probe snugly into the ear canal (best
to insert deep), press the scan button, release it. When you hear a beep
sound, the measurement is complete. Then remove the thermometer from
the ear. The display shows the measure temperature.
3

ENGLISH
4. Measuring again: If you want to measure again, please release the scan
button and wait for the “?” symbol to display, then press scan to measure
again.
Advice: The interval between each reading should be at least 1 minute.
5. Memory search: Press the on/
recall button, the last ten memories
(NO.9-NO.0) will take turns and show up
Fig. C Fig. D
on the LCD as Fig. C and Fig. D.
6. The LCD will displays “Er 1” as Fig. E and
cannot displays temperature when the
ambient temperature is out of the range
Fig. E
of 10°C to 35°C.
Note: Before measuring, the thermometer must be stabilized at the
operating condition for a minimum of 30 min.
7. Shut o: The thermometer will automatically shut o if it’s not operated for
a minute.
Cleaning and Storage
1. Store the thermometer in a dry location free from dust
and contamination and away from direct sunlight. The
ambient temperature of the storage location should be
fairly constant. Constant and within the range of -25°C
to 55°C.
2. Use an alcohol swab or cotton swab moistened with alcohol (70% isotropy)
to clean the thermometer casing and the measuring probe. Ensure that no
liquid enters the interior of the thermometer.
3. Never use abrasive cleaning agents, thinners or gasoline for cleaning and
never immerse the instrument in water or other cleaning liquids. Take care
not to scratch the surface of the probe lens or display.
Replacing the batteries
1. When the voltage of the battery is low, the LCD display shows a symbol.
Please replace the battery in the unit. The thermometer cannot work
accurately when the battery is low.
2. The thermometer is supplied with a 3 V Lithium battery (CR2032), Insert a
new battery when the low voltage symbol appears on the LCD.
4

ENGLISH
3. Remove the battery cover and push down the metal button, the battery will
be bounced out, then you can take out the old battery.
4. Place a new battery, the positive pole “+” up and negative pole “–” down.
5. Please take out the battery in case of battery leaking if the unit will be
unused for over six months.
Safety precautions:
Do not expose the product to water or moisture.
Maintenance:
Clean only with a dry cloth.
Do not use cleaning solvents or abrasives.
Warranty:
No guarantee or liability can be accepted for any changes and modications of the product or damage caused due to
incorrect use of this product.
General:
Designs and specications are subject to change without notice. All logos, brands and product names are trademarks or
registered trademarks of their respective holders and are hereby recognized as such.
Attention:
This product is marked with this symbol. It means that used electrical and electronic products should not be
mixed with general household waste. There is a separate collections system for these products.
This product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all
member states of the European Union. It also complies to all applicable specications and regulations in the country of
sales.
Formal documentation is available upon request. This includes, but is not limited to: Declaration of Conformity (and
product identity), Material Safety Data Sheet, product test report.
Please contact our customer service desk for support:
via website: http://www.nedis.com/en-us/contact/contact-form.htm
via e-mail: service@nedis.com
via telephone: +31 (0)73-5993965 (during oce hours)
NEDIS B.V., De Tweeling 28, 5215 MC ’s-Hertogenbosch, THE NETHERLANDS
5