Konig Electronic Wireless alarm system: инструкция
Раздел: Безопасность
Тип:
Инструкция к Konig Electronic Wireless alarm system

SEC-ALARM200
MANUAL (p. 2)
ANLEITUNG (S. 6)
WIRELESS ALARM SYSTEM
DRAHTLOSES ALARMSYSTEM
MODE D’EMPLOI (p. 10)
GEBRUIKSAANWIJZING (p. 14)
SYSTEME D'ALARME SANS FIL
DRAADLOOS ALARMSYSTEEM
MANUALE (p. 18)
MANUAL DE USO (p. 22)
SISTEMA D'ALLARME SENZA FILI
SISTEMA DE ALARMA INALÁMBRICA
MANUAL (p. 27)
HASZNÁLATI ÚTMUTATÓ (o. 31.)
SISTEMA DE ALARME SEM FIOS
VEZETÉK NÉLKÜLI RIASZTÓRENDSZER
KÄYTTÖOHJE (s. 35)
BRUKSANVISNING (s. 39)
LANGATON HÄLYTYSJÄRJESTELMÄ
TRÅDLÖST ALARMSYSTEM
NÁVOD K POUŽITÍ (s. 43)
MANUAL DE UTILIZARE (p. 47)
BEZDRÁTOVÝ POPLAŠNÝ SYSTÉM
SISTEM DE ALARMĂ WIRELESS
ΕΓΧΕΙΡΙΔΙΟ XPHΣHΣ (σελ. 51)
BRUGERVEJLEDNING (s. 55)
ΑΣΥΡΜΑΤΟ ΣΥΣΤΗΜΑ ΣΥΝΑΓΕΡΜΟΥ
TRÅDLØST ALARMSYSTEM
ИНСТРУКЦИЯ (стр. 64)
VEILEDNING (s. 60)
БЕСПРОВОДНАЯ СИСТЕМА
TRÅDLØST ALARMSYSTEM
СИГНАЛИЗАЦИИ
KILAVUZ (s. 69)
KABLOSUZ ALARM SİSTEMİ
2013-10-22

ENGLISH
WIRELESS ALARM SYSTEM
QUICK SETUP GUIDE
Functions include:
Alert – Advises you to what is happening around the house.
Alarm – Protects your home / assets while you are away.
Communication – Calls you during an emergency, you can also call in to perform a variety of
operations.
This Quick Guide will show you how to setup the system and use basic functions. It is strongly
recommended that you refer to the User’s Instructions for full illustrations on how the system should be
installed and operated.
Installation of the Control Panel
1. Plug in the adapter to a wall socket
and the other end should be
connected to the socket on the
Control Panel marked “DC 12 V”. You
should hear 3 beeps.
2. Remove the screw on the battery
cover and insert 4 pcs of AAA
batteries into the battery holder.
Tighten the screw afterwards.
3. Plug in a phone line from the “LINE”
socket to the phone outlet on the
wall.
4. If you want to connect a telephone to
the Control Panel, the phone can be
plugged into the socket marked
“PHONE” on the Control Panel.
2

Installation of Sensors - Batteries
Insert batteries in all the
sensors and mount them
accordingly. Please refer to the
User’s Instructions for details
on how to install the Motion
Sensor and Door / Window
Remove the yellow
Sensor.
protective tag from
Insert 9V alkaline
the sensors.
battery in the sensor
Operation - Alert Mode
All the sensors are preprogrammed at the factory, so the
Control Panel can communicate with these sensors after the
batteries are installed properly.
Door/Window Sensor
Activate the Door / Window Sensor, you will hear continuous
beeping, one beep at a time, indicating zone 1 sensor is
activated. Activate the other Door / Window Sensor, you will
hear continuous beeping, two beeps at a time, indicating
Beep
zone 2 sensor is activated.
Notes: The door/Window Sensor is factory default in zone 1
Activate the sensor
Close the door, and
by opening the door,
beeping stop.
and zone 2.
you will hear voice
announcement and
continuous beeping.
Motion Sensor
To perform the walk test, its necessary to enable the Alert Zone (Bypass Zone) feature in the Control
Panel. After the walk test, it needs to disable this alert zone feature otherwise it will bypass the signal in
the alarm mode.
To enable the alert zone feature:
1. Press [PROG] + MPIN [factory default 1 2 3 4].
2. Press [8] to select Alert Zone.
3. Press [8] to enable for zone 3. The zone 3 LED will stay ON after selected.
4. Press [PROG] when finished.
Walk in front of the Motion Sensor, you will hear the continuous beeping from the Control Panel.
Beeping will continue for approx. 20 seconds for every motion detected.
To disable the alert zone feature:
1. Press [PROG] + MPIN [factory default 1 2 3 4].
2. Press [8] to select Alert Zone.
3. Press [3] to disable for zone 3. The zone 3 LED will flash after selected.
4. Press [PROG] when finished.
Notes:
1) The Motion Sensor is factory default in zone 3.
2) If the Motion Sensor doesn’t respond to your movement, try not to move in front of the sensor for
20 seconds (i.e. no motion is detected in 20 seconds), then walk again. The Motion Sensor is
designed to be triggered only if no motion is detected for 20 seconds.
Program Emergency Phone Number
During an emergency, the Control Panel can call up to 5 phone numbers to inform you about an
emergency situation. There are 5 phone memories, it will first call phone memory 1, then phone
memory 2, etc. It will call phone memory 5 last. Each phone number can have a redial count up to
3

9 times, and the emergency voice message can be repeated up to 9 times. To program phone numbers,
follow the procedures below.
Function Key Description Note
Enter program mode by MPIN [PROG] [MPIN]
Select program phone numbers [1]
Select phone memory [1] to [5]
Enter the phone number, then [Arm] [Phone Number] [Arm] Phone number
Enter redial count, then [Arm] [1] to [9] [Arm]
Enter message repeat count, then [Arm] [1] to [9] [Arm]
Note: Do not program police, or fire station phone numbers into any of the phone memories.
Operation - Alarm
Arm
You should arm the Control Panel if you are the last person to leave
the house. To arm, press [Arm], Control Panel will beep for
45 seconds, this is called the exit delay. You must leave the house
within 45 seconds.
Note: Control Panel can only be armed when no sensor is triggered.
Triggered sensors must be deactivated in order to successfully arm
the system.
Disarm
If you are the first one to enter the house with the Control Panel armed, you must disarm it within the
entry delay period of 30 seconds, otherwise the alarm will sound. To disarm, enter the 4-digit password,
either the master password or secondary password.
Default Master Password: 1234
Default Secondary Password: 0000
Note: It is strongly recommended that you change both master and secondary passwords from the
default value. Please refer to the User’s Instructions for details.
Panic
During an emergency, any user can activate the alarm immediately by
pressing the red panic button. When the panic button is pressed, 2
things will happen:
1. Alarm will sound;
2. Control Panel will call the pre-programmed phone numbers for
assistance.
4

When you test this feature, beware of the intensity of the alarm. You
should also advise those who will be called (recipients of the 5 phone
numbers) so they know you are testing the system.
In order to terminate the alarm, or stop the Control Panel from calling
to the 5 phone numbers, users can enter either the master or
Alarm
secondary password. This will stop the alarm from sounding and
dialer will stop calling out for help.
Operation - Communication
Users can call in from any touch tone phone to check the system status, arm or disarm the system.
Please refer to the User’s Instructions for details.
You have now installed the system to perform the most basic functions. To customize the Control Panel
or program other advanced features, please refer to the User’s Instructions.
Safety precautions:
To reduce risk of electric shock, this product should ONLY be
opened by an authorised technician when service is required.
Disconnect the product from mains and other equipment if a
problem should occur. Do not expose the product to water or
moisture.
Maintenance:
Clean only with a dry cloth. Do not use cleaning solvents or abrasives.
Warranty:
No guarantee or liability can be accepted for any changes and modifications of the product or damage
caused due to incorrect use of this product.
General:
- Designs and specifications are subject to change without notice.
- All logos, brands or brand logos and product names are trademarks or registered trademarks of their
respective holders and are hereby recognised as such.
- This manual was produced with care. However, no rights can be derived. König Electronic can not
accept liability for any errors in this manual or their consequences.
- Keep this manual and packaging for future reference.
Attention:
This product is marked with this symbol. It means that used electrical and electronic products
should not be mixed with general household waste. There is a separate collections system for
these products.
This product has been manufactured and supplied in compliance with all relevant regulations and
directives, valid for all member states of the European Union. It also complies with all applicable
specifications and regulations in the country of sales.
Formal documentation is available upon request. This includes, but is not limited to: Declaration of
Conformity (and product identity), Material Safety Data Sheet and product test report.
Please contact our customer service desk for support:
via website: http://www.nedis.com/en-us/contact/contact-form.htm
via e-mail: service@nedis.com
via telephone: +31 (0)73-5993965 (during office hours)
NEDIS B.V., De Tweeling 28, 5215 MC ’s-Hertogenbosch, THE NETHERLANDS
5